Resumen del contenido incluido en la página 1
�
�
�
�
�
�
�
�
�
INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
WARNING!
Chateau™
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
Direct Vent Gas
MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
Fireplace
INJURY OR LOSS OF LIFE.
Model: DVT38S2IN
FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.
WHAT TO DO IF YOU SMELL GAS:
• Do not tr
Resumen del contenido incluido en la página 2
Chateau™ Direct Vent Gas Fireplace Table of Contents Please read the installation & operating instructions before using this appliance. Thank you and congratulations on your purchase of a CFM Corporation fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions Important Curing/Burning Instructions ..................
Resumen del contenido incluido en la página 3
Chateau™ Direct Vent Gas Fireplace Installation & Operating Instructions This gas fireplace should be installed by a qualified this fireplace must be installed on a metal or wood panel installer, preferably NFI or WETT (Canada) certified, in extending the full width and depth of the fireplace. accordance with local building codes and with current CSA- 12. This fireplace requires adequate ventilation and B149.1 Installation codes for Gas Burning Appliances and combustion air to operate properly.
Resumen del contenido incluido en la página 4
Chateau™ Direct Vent Gas Fireplace Fireplace Dimensions Finished Wall 24 ¹⁄₂” (622 mm) C L 25 ����” for Flush Install 16” (406 mm) 3/4" (19 mm) (649 mm) I.D. Minimum Clearance to Combustibles 24 ���" Standard Framing C L (622 mm) 10���" (267 mm) Exterior Side 3/4" NOTE: Noncombustible insula- 51���" (1299 mm)* (If installed on (19 mm) tion may be placed behind the outside wall) C Glass L facing material. Only 25 ����” Noncombustible (649 mm) Material in This Area 49���" Sides and Top (1
Resumen del contenido incluido en la página 5
Chateau™ Direct Vent Gas Fireplace Combustible Clearance to Combustibles Framing and Finish Wall Above Top of Unit to Ceiling ................................ 36” (914 mm) � Standoffs Front of Unit to Combustibles (both sides) 36” (914 mm) May use com- � bustible facing Appliance material in this Top Standoffs .............................................. 0” (0 mm) area � Standoff Bottom* ....................................................... 0” (0 mm) Side Standoffs .................
Resumen del contenido incluido en la página 6
Chateau™ Direct Vent Gas Fireplace Hearth A hearth is not mandatory but is recommended for aesthetic purposes. We recommend a noncombustible hearth which projects out 12” (305 mm) or more from the front of the fireplace. The hearth cannot exceed 1 ¹⁄₂” (38 mm) in height from bottom of fireplace for ease of door accessibility. (Fig. 4) Cold climate installation recommendation: When installing this unit against a non- insulated exterior wall or chase, it is mandatory the outer walls be insu
Resumen del contenido incluido en la página 7
Chateau™ Direct Vent Gas Fireplace Gas Inlet and Manifold Pressures 1/2” NPT X 1/2” Flare Shut-off Valve Natural LP (Propane) Minimum Inlet Pressure 5.5” w.c. 11.0” w.c. Maximum Inlet Pressure 14.0” w.c. 14.0” w.c. Manifold Pressure 3.5” w.c. 10.0” w.c. 1/2” Gas Tight or Tinned Copper High Elevations (from valve) 1/2” Gas Supply (Not provided) FP297A Input ratings are shown in BTU per hour and are certified without deration for elevations up to Fig. 6 Typical gas supply installation. 4,
Resumen del contenido incluido en la página 8
Chateau™ Direct Vent Gas Fireplace Control System Gas Supply The gas control system is located on the right hand side Fitting of the firebox behind an access panel and the decora- tive brick panel. The fireplace is operated using only the hand held remote control unit. The system wiring diagram is shown in Figure 11. NOTE: If you choose Pressure Learn Button Test to install the battery back-up, Model DVTBBK, refer Ports to Item #16 in the next section. Control System Installation 1. Locate
Resumen del contenido incluido en la página 9
Chateau™ Direct Vent Gas Fireplace White or Green To Pilot Ignitor Green or White White or Orange Orange or White To Pilot Flame Sensor DC Motor Pilot Main Module AF-4000 Learn Main Remote Battery Button Back-Up Pack Power Orange Black Remote/Off Red Module Red Brown Switch Black Continuous Pilot ON/OFF Switch Pulse/Continuous Button Black Gnd Brown (SWI) (Optional Brown ON/OFF Switch) (SWI) Red Black AC Adaptor Extension Harness FP1795 Fig. 9 DVT38S2 wiring diagram. CAUTION: Turn off the
Resumen del contenido incluido en la página 10
Chateau™ Direct Vent Gas Fireplace Remote Control Transmitter Operating Instructions Introduction This transmitter operating range is approximately 20 feet (6 m). The transmitter operates on one of 1,048,576 security codes that are programmed into the transmitter at the factory; this transmitter operates on radio frequencies with non- Transmitter Wall Clip Slot The transmitter operates on (2) 1.5V AAA batteries. It is recom- �� On H/L mended that ALKALINE batteries always be used for longer
Resumen del contenido incluido en la página 11
Chateau™ Direct Vent Gas Fireplace Setting ° F / ° C Scale ��� � � The factory setting for temperature is ° F. To change this setting to ° C; Press the ON H/L key and the OFF CONTINUOUS PILOT � ��� ��� key on the transmitter at the same time. This will change from ° F to ° C. Follow this same procedure to change from ° C to ° F. Manual Function To operate the system in the manual “MODE” do the follow- ing: ���� ON - HI Flame Operation Press and release the ON H/L key. The appliance flame will
Resumen del contenido incluido en la página 12
Chateau™ Direct Vent Gas Fireplace To Change the Set Temperature Press and hold the SET key until the desired set tem- perature is reached. (By pressing and holding the set key, the LCD screen set numbers will increase from 45° to 99°, then restart at 45°) ��� ���� Release the SET key. The LCD screen will display the set ��� ���� temperature for 3 seconds, then will flash the set tem- perature for 3 seconds, then the LCD screen will default to display the room temperature. To Disengage Therm
Resumen del contenido incluido en la página 13
Chateau™ Direct Vent Gas Fireplace Operational Notes: The Thermostatic feature on the transmitter operates the appliance whenever the ROOM TEMPERATURE varies a certain number of degrees from the SET TEMPERATURE. This variation is called the “SWING” or TEMPERATURE DIFFERENTIAL. The normal operating cycle of an appliance may be 2-4 times per hour depending on how well the room or home is insulated from the cold or drafts. The factory setting for the “swing number” is 2. This represents a tempe
Resumen del contenido incluido en la página 14
Chateau™ Direct Vent Gas Fireplace General Venting Your fireplace is approved to be vented either through There must not be any obstruction such as bushes, gar- the side wall, or vertical through the roof. den sheds, fences, decks or utility buildings within 24” (610mm) from the front of the termination hood. • Only CFM Corporation venting components spe- cifically approved and labelled for this fireplace Do not locate termination hood where excessive snow may be used. or ice build up may occur.
Resumen del contenido incluido en la página 15
V Operable Chateau™ Direct Vent Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL G V N H N A D E L C B ����� B V B V ������ V Fixed Operable Closed F V B M V B J X B I X V K A CFM145a VENT TERMINATION X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED CFM145 V 1 2 Canadian Installations US Installations A = Clearance above grade, veranda, porch, 12” (30 cm) 12” (30 cm) CFM145a deck, or balcony DV Termin Location 5/01/01 Rev. 12/05/01 B = Clearan
Resumen del contenido incluido en la página 16
Chateau™ Direct Vent Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner D C C F = Combustible G = 6" (152 mm) Combustible V G 6" (152 mm) Noncombustible V E 2" (51 mm) Noncombustible O V F 2" (51 mm) Balcony - Balcony - with no side wall with perpendicular side wall E = Min. 6” (152 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O = 8’ (2.4 m)
Resumen del contenido incluido en la página 17
Chateau™ Direct Vent Gas Fireplace proper sealing. Be sure to always attach straps on up- • Vent must rise a minimum of 2’ (610 mm) before per elbow to a structural framing member. offset is used. For vertical installations, continue installing the pipe as • Termination height must conform to roof clearance required until pipe is installed up through the ceiling. At as specified in Figure 37. this point, you must install a firestop spacer. �� �� Pipe Section �� �� Pipe �� Rim UP �� Hem �� �� L
Resumen del contenido incluido en la página 18
Chateau™ Direct Vent Gas Fireplace When the vent termination exits through foundations less than 20” (508mm) below siding outcrop, the vent pipe must be flush with the siding. It is always best to locate the fireplace in such a way A that minimizes the number of offsets and horizontal B 10' vent length of vent pipe from the flue collar of the fire- (3m) place to the face of the outer wall. Horizontal plane means no vertical rise exists on this portion of the vent assembly. 20’ (6m) A + B = 17
Resumen del contenido incluido en la página 19
Chateau™ Direct Vent Gas Fireplace Vent Opening for Combustible Wall 16 ¹⁄₄” Firestop (413mm) Zero Clear- ance Sleeve Framing 16 ¹⁄₄” Detail (413mm) X Fireplace Hearth Vent Opening for Noncombustible Wall 11 ¹⁄₄” (286mm) VO584-100 Fig. 18 Locate vent opening on wall. FP1456 STEP 2 Fig. 20 Vertical height requirement. Measure wall thickness and cut zero clearance sleeve STEP 5 VO584-100 parts to proper length (MAXIMUM 12”/305 mm). As- Tape the inner and outer flue collars of the fireplace Vent
Resumen del contenido incluido en la página 20
Chateau™ Direct Vent Gas Fireplace Support horizontal pipes every 3’ (914 mm) X with metal pipe straps. Check fireplace to make sure it is levelled and properly positioned. Sidewall Installation with Stationary Glass Facing Outside CAUTION: Unit must be installed with station- ary glass facing outside. (Control housing will be located on the left side of the unit when facing the unit from inside the house.) Failure to do so will result in a major reconstruction and