Pure, Pure SE
User Guide
Resumen del contenido incluido en la página 2
Content Content Your Pure hearing instrument 4 Intended use 6 General notes on safety 7 Handling of standard and rechargeable batteries 9 Low battery indicator 9 Inserting the battery 10 Removing the battery 11 Inserting and removing your hearing instrument 12 Inserting your hearing instrument 12 Removing your hearing instrument 12 Turning your hearing instrument on and off 13 Via battery compartment 13 Via push button 13 Via remote control 13 Power-on delay 14 Changing the hearing program 15
Resumen del contenido incluido en la página 3
Content Changing the volume 16 Automatic 16 Via remote control 16 Functionalities 17 Maintenance and care 18 Domes and receiver molds 19 Exchanging the receiver unit 23 Accessories 24 Charger 24 Tek wireless enhancement 25 Remote control 26 Troubleshooting 27 Technical information 28 Disposal information 30 3
Resumen del contenido incluido en la página 4
Your Pure hearing instrument Y our Pure hearing instrument Pure Pure SE battery type 312 battery type 10 rechargeable non-rechargeable ① Receiver unit ⑥ Push button ② Dome ⑦ Battery compartment ③ Receiver mold ⑧ Charging contacts ④ Microphone openings ⑨ Serial number ⑤ Microphone cover ⑩ Type of hearing instru- ment 4
Resumen del contenido incluido en la página 5
Your Pure hearing instrument Your Hearing Care Professional offers an assortment of receiver lengths and dome sizes to fi t your ear best. 5
Resumen del contenido incluido en la página 6
Intended use Int ended use Hearing instruments are intended to improve the hearing of hearing impaired persons. Diagnosis and prescription of a hearing instrument must be performed by hearing health specialists, e.g. ENT doctors, audiologists or acous- ticians. Read and follow the instructions of this user guide to avoid injuries or damage to the hearing instruments. Symbols: Be aware to information marked with the warning symbol WARNING, CAUTION or NOTICE! WARNING points out a situation t
Resumen del contenido incluido en la página 7
General notes on safety General no tes on safety NOTICE Your hearing instruments are sensitive to extreme heat, high humidity, strong magnetic fi elds (> 0.1T), X-rays and mechanical stress. Do not expose your hearing instruments to extreme temperature or high humidity. Do not leave them in direct sunlight. Do not wear them in the shower or when you apply make-up, perfume, aftershave, hairspray or suntan lotion. Do not wear your hearing instruments when you are exposed to short-waves, a
Resumen del contenido incluido en la página 8
General notes on safety WARNING Hazard of explosion! Do not use your hearing instruments in areas where there is a danger of explosions (e.g. min- ing). NOTICE Leaking batteries damage the hearing instruments. Turn the hearing instruments off when not in use to preserve the battery. Remove batteries when the instruments are not in use for a prolonged period of time. NOTICE Batteries contain harmful substances that pollute the environment. Do not throw used batteries into household trash
Resumen del contenido incluido en la página 9
Handling of standard and rechargeable batteries Handling of st andard and rechargeable batteries original size Always use the right size of batteries. Charge the rechargeable batteries before fi rst use. Remove the tab on standard batteries only when you are ready to use them. The positive (+) side of the batteries is always the smooth side. Always keep spare batteries with you. Low battery indicator Your Hearing Care Professional can activate an acoustic signal to inform you when the
Resumen del contenido incluido en la página 10
Handling of standard and rechargeable batteries Inser ting the battery Open the battery compartment com- pletely using your fi ngernail as shown in the illustration. Insert the proper size battery. Make sure that the "+" symbol on the battery points up as shown in the picture Close the battery compartment. Do not force the door shut. If it does not close easily, check to see if the battery was inserted properly. When the battery door is completely closed, your hearing instrument is rea
Resumen del contenido incluido en la página 11
Handling of standard and rechargeable batteries Removing the battery Open the battery compartment com- pletely. Normally the battery drops out when the compartment is completely open. If the battery does not come out, lightly tap the instrument or use the magnet stick available as accessory to remove the battery. 11
Resumen del contenido incluido en la página 12
Inserting and removing your hearing instrument Inser ting and removing your hearing instrument For side recognition ask your Hearing Care Professional to apply colored markers in the bat- tery compartment. If the marker in the battery compartment is in red, the hearing instrument is intended for the right ear. If the marker is in blue, the hearing instrument is for the left ear. Inser ting your hearing instrument Turn your hearing instrument off. Hold the receiver mold / dome between yo
Resumen del contenido incluido en la página 13
Turning your hearing instrument on and off T urning your hearing instrument on and off Ask your Hearing Care Professional to check off the relevant information. Via battery compartment On Close the battery compartment. Of f Open the battery compartment. Via push button On Press the push button for 2 seconds. Of f (stand by) Press the push button for 2 seconds. Via remote control Refer to the remote control user guide. 13
Resumen del contenido incluido en la página 14
Turning your hearing instrument on and off P o w er -on dela y Your hearing instrument is equipped with a "power-on delay" feature which can be activated by your Hearing Care Professional. This allows you to turn the hearing instrument on with an automatic delay of 6, 12 or 18 seconds, so that you may insert the hearing instrument into your ear without experiencing unpleasant feedback (whistling). 14
Resumen del contenido incluido en la página 15
Changing the hearing program Changing t he hearing program Via push button Press the push button. The hearing instrument changes to the next program. Via remote control Refer to the remote control user guide. 15
Resumen del contenido incluido en la página 16
Changing the volume Changing t he volume The volume of your hearing instruments is controlled automatically and there is no need to manually adjust it. Should you prefer manual volume control, your Hearing Care Professional can program the hearing instrument for manual adjustment. A ut omatic The volume is adjusted automatically when in use. Via remote control Refer to the remote control user guide. 16
Resumen del contenido incluido en la página 17
Functionalities Functionalities Your Hearing Care Professional can activate the following functionalities. e2e wireless function ■ Allows the use of a remote control. ■ Automatically adjusts both hearing instruments simultaneously to change the instrument set- tings, e.g. volume or program. The performance of the e2e wireless function may be affected by electromagnetic interference – e.g. from a computer monitor or fl uorescent lamp system. Move away from the source of interference if
Resumen del contenido incluido en la página 18
Maintenance and care Maint enance and care Your hearing instruments are highly sensitive systems. Proper care and handling will ensure the best possible performance. Clean instruments regularly to prevent damage to the hearing instruments and to avoid health problems. NOTICE Do not put the hearing instruments in water. Clean your hearing instruments with a soft, dry tissue, as necessary. If the hearing instruments sound distorted or weak ask your Hearing Care Professional to exchange th
Resumen del contenido incluido en la página 19
Maintenance and care Domes and receiver molds CAUTION Risk of injury caused by incorrect use of receiver unit and domes/receiver molds. Always wear the receiver unit with a dome or receiver mold. Make sure that the dome/receiver mold is com- pletely attached to the receiver unit. If the dome/receiver mold remains in your ear, have it removed by a medical professional. Insert the receiver unit with the dome/receiver mold carefully and not too deeply into the ear. Use the receiver unit a
Resumen del contenido incluido en la página 20
Maintenance and care Your hearing instruments have one of the following ear pieces: Single dome Double dome Receiver mold Cleaning domes and receiv er molds Cerumen (ear wax) on the dome/ receiver mold affects sound quality. Clean domes/ receiver molds right after taking the hearing instruments off. This way, cerumen can not dry and harden. Remove cerumen with a soft tis- sue. No other tools are required. To remove dried cerumen, moisten the soft tissue with a cerumen solvent. Dab the