Resumen del contenido incluido en la página 1
601
WELLSBLOOMFIELD,LLC
2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439
fax: 775-689-5976
telephone: 775-689-5707
www.wellsbloomfield.com
OWNERS MANUAL
for
INTEGRITY™
DECANTER
COFFEE BREWERS
MODELS
9010 9012
9016
Includes:
Installation
Use & Care
Servicing Instructions
Model 9012 Brewers
with optional
8900-Series Glass Decanters
PRINTED IN UNITED STATES OF AMERICA
p/n 75815 Rev. F ECN-13387 M601 071112 cps
Resumen del contenido incluido en la página 2
601 75815 Owners Manual Integrity Decanter Brewers WARRANTY STATEMENT All electrical equipment manufactured by WELLS It also does no t apply if the serial nameplate has been BLOOMFIELD, LLC is warranted against defects in materials removed or unauthorized service personnel perform service. and workmanship for a period of one year from the date of The prices charged by Bloomfield Industries for its products original installation or eighteen (18) months from the date of are ba
Resumen del contenido incluido en la página 3
TABLE OF CONTENTS WARRANTY STATEMENT xi Thank You for purchasing this Wells Bloomfield appliance. SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 Proper installation, professional PRECAUTIONS & GENERAL INFORMATION 3 operation and consistent AGENCY APPROVAL INFORMATION 3 maintenance of this appliance will INSTALLATION INSTRUCTIONS 4 ensure that it gives you the very best performance and a long, OPERATION 6 economical service life. BREWING COFFEE
Resumen del contenido incluido en la página 4
601 75815 Owners Manual Integrity Decanter Brewers FEATURES AND OPERATING CONTROLS Fig. 1 Features & Operating Controls 2
Resumen del contenido incluido en la página 5
PRECAUTIONS AND GENERAL INFORMATION WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: INJURY HAZARD All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes. Failure could result in p
Resumen del contenido incluido en la página 6
601 75815 Owners Manual Integrity Decanter Brewers INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION IMPORTANT: Unpack the unit. Inspect all components for completeness and To enable the installer to make a condition. Ensure that all packing materials have been removed quality installation and to mini- from the unit. mize installation time, the follow- Verify that the Spray Head Gasket and Spray Disk are properly ing suggestions and tests should ins
Resumen del contenido incluido en la página 7
INSTALLATION INSTRUCTIONS (continued) NOTE: This equipment must be In some areas, local codes require a backflow preventer (check installed to comply with valve) to be installed on the inlet water line. If a backflow applicable federal, state and preventer is used, you must install a water hammer arrester in local plumbing codes and the incoming line, between the backflow preventer and the ordinances. brewer inlet, as far away from the brewer as space will all
Resumen del contenido incluido en la página 8
601 75815 Owners Manual Integrity Decanter Brewers OPERATION Fig. 4 Brewer Operation Diagram IMPORTANT: A. START-UP Tank must be full of water For initial start-up, or if the brewer has not been used for an before connecting brewer extended period of time: to electrical power. Heating elements will be ♦ Be sure spray disk and brew gasket are properly installed in the damaged if allowed to brew head. operate without being fully ♦ Be sure the water
Resumen del contenido incluido en la página 9
OPERATION (continued) WATER HEATER Water temperature is sensed by a thermobulb inserted into the water tank. This temperature signal is fed to the thermostat, which controls line power to the heating element. The setpoint temperature is adjustable at the thermostat. The element is protected from over- temperature by a hi-limit thermostat. Fig. 5 Heat Control Diagram WATER FLOW POUR-OVER FEATURE Pouring any amount of cold water into the pour-over op
Resumen del contenido incluido en la página 10
601 75815 Owners Manual Integrity Decanter Brewers BREWING COFFEE B. PREPARATION CAUTION: BURN HAZARD Place one (1) genuine Bloomfield paper filter in the brew chamber. Exposed surfaces of the Add a pre-measured amount of brewer, brew chamber and fresh coffee grounds. decanter may be HOT to Gently shake the brew chamber to the touch, and can cause level the bed of grounds. Slide the serious burns. brew chamber into place under the brew head. Fig. 7 Brew Ch
Resumen del contenido incluido en la página 11
CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer CAUTION: BURN HAZARD PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Brewing and serving temperatures of coffee are FREQUENCY: Daily extremely hot. Hot coffee will cause TOOLS: Mild Detergent, Clean Soft Cloth or Sponge serious skin burns. Bristle Brush. CAUTION: 1. Disconnect brewer from electric power. SHOCK HAZARD Allow brewer to cool before cleaning. Do not
Resumen del contenido incluido en la página 12
601 75815 Owners Manual Integrity Decanter Brewers TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won’t heat Brewer unplugged or circuit Check power supply cord breaker tripped Check / reset circuit breaker Thermostat set too low Set for desired temperature Hi-Limit thermostat tripped Allow to cool Reset hi-limit (8786, 8788) Damaged internal component or Examine wiring & connectors, wiring thermostat and heating element Repair/r
Resumen del contenido incluido en la página 13
SERVICING INSTRUCTIONS ACCESS PANELS CAUTION: SHOCK HAZARD Each warmer plate has a center stud which screws into a bracket. Warmer plates on Canadian brewers are secured with a Opening access panels or nut. Remove button plug on bottom of brewer to access nut on removing warmer plates on this main warmer. Remove top panel to access nuts on top warmers. brew may expose uninsulated Remove warmer plates by turning counter-clockwise. electrical components. Disconnect bre
Resumen del contenido incluido en la página 14
601 75815 Owners Manual Integrity Decanter Brewers SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT CAUTION: SHOCK HAZARD Unplug power cord or turn circuit breaker OFF. Remove top panel. These procedures involve exposed electrical circuits. Pull vent tube out of tank lid and insert a thermometer of known These procedures are to be accuracy in vent hole. Reconnect brewer to electrical power. performed by qualified technical personnel only.
Resumen del contenido incluido en la página 15
SERVICING INSTRUCTIONS (continued) TIMER ADJUSTMENT IMPORTANT: Water pressure must be between 20 p.s.i and The amount of water dispensed automatically during a brew cycle 90 p.s.i. flowing pressure. is controlled by the timer. If water pressure exceeds this Place empty decanter under brew chamber. Press BREW value, or if water pressure button. Brewer should dispense one decanter of water. To varies greatly, a pressure adjust amount: regulator must be
Resumen del contenido incluido en la página 16
601 75815 Owners Manual Integrity Decanter Brewers SERVICING INSTRUCTIONS (continued) IMPORTANT: When replacing REPLACE HEATING ELEMENT heating element, also replace Remove tank lid assembly as described on page 13. seal gaskets. Remove two hex nuts holding element to cover. Pull element from mounting holes. Reassemble in reverse order. REPLACE SOLENOID Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuously from brew head. NOTE: Wren
Resumen del contenido incluido en la página 17
SERVICING INSTRUCTIONS (continued) REPLACE TIMER ASSEMBLY Unplug power cord or turn circuit breaker OFF. Remove front panel. Remove knob and three screws holding timer to bracket. Disconnect wiring to timer. Reassemble in reverse order. Adjust timer as described on page 13 IMPORTANT: When replacing REPLACE HOT WATER FAUCET COIL water faucet coil, also replace Symptom: Brewer drips continuously from brew head, except seal gaskets. when faucet valve is tur
Resumen del contenido incluido en la página 18
601 75815 Owners Manual Integrity Decanter Brewers SERVICING INSTRUCTIONS (continued) CAUTION: PROCEDURE: Delime the Water Tank CHEMICAL BURN PRECAUTIONS: Disconnect brewer from electric power. HAZARD Allow brewer to cool. Deliming chemicals may be caustic. Wear appropriate FREQUENCY: As required (Brewer slow to heat) protective gloves and goggles during this procedure. TOOLS: Deliming Solution Never siphon deliming Protective Gloves, Goggles & Apron
Resumen del contenido incluido en la página 19
7. Set the tank back into the brewer. Reassemble the tank lid to NOTE: Normally, silicone the water tank. Make sure the gasket is properly in place, hoses do not need to be then reinstall the hold-down strap. delimed. Should deliming hoses become necessary, 8. Reinstall wiring to heating element and thermostat. Reinstall Bloomfield recommends the hi-limit thermostat (if removed). For brewers with hot replacing the hoses. water faucet, reassemble faucet piping.
Resumen del contenido incluido en la página 20
601 75815 Owners Manual Integrity Decanter Brewers EXPLODED VIEW & PARTS LIST HOT WATER TANK ASSEMBLY 14 60 59 61 68 13 50 55 62 52 54 63 66a 56 57 66b 56 70 66 58 50 67 ALTERNATE ITEM PART NO. DESCRIPTION USED ON 13 8043-5 HOLD-DOWN STRAP 9010, 9012(CA), 9016(EX) 14 83457 NUT, HEX 8-32 KEPS 9010, 9012(CA), 9016(EX) 8512-51 THERMOSTAT (BLACK BODY - INCL. SEAL & MOUNTING SCREWS) 50 9010, 9012(CA), 9016(EX) 86280 THERMO (ALT) (GRAY BODY - INCL. TUBE & MOUNTING SCREWS) 52 8512-41 SEAL W