Resumen del contenido incluido en la página 1
OM-1500-9 207 749K
2006 −05
Processes
MIG (GMAW) Welding
Flux Cored (FCAW) Welding
(Gas- And Self-Shielded)
Description
Wire Feeder
S-74DX
File: MIG (GMAW)
Visit our website at
www.MillerWelds.com
Resumen del contenido incluido en la página 2
From Miller to You Thank you and congratulations on choosing Miller. Now you can get the job done and get it done right. We know you don’t have time to do it any other way. That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality. Like you, his customers couldn’t afford anything less. Miller products had to be more than the best they could be. They had to be the best you could buy. Today, the people that bu
Resumen del contenido incluido en la página 3
TABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-3. Additional Symbols For Insta
Resumen del contenido incluido en la página 4
Declaration of Conformity for European Community (CE) Products This information is provided for units with CE certification (see rating label on unit). NOTE Manufacturer: European Contact: Miller Electric Mg. Co. Mr. Danilo Fedolfi, 1635 W. Spencer St. Managing Director Appleton, WI 54914 USA ITW Welding Products Italy S.r.l. Phone: (920) 734-9821 Via Privata Iseo 6/E 20098 San Giuliano Milanese, Italy Phone: 39(02)98290-1 Fax: 39(02)98290203 European Contact Signature: Declares that the produ
Resumen del contenido incluido en la página 5
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _3/05 Warning: Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. This group of symbols means Warning! Watch Out! possible Marks a special safety message. ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessa
Resumen del contenido incluido en la página 6
ARC RAYS can burn eyes and skin. BUILDUP OF GAS can injure or kill. Shut off shielding gas supply when not in use. Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays Always ventilate confined spaces or use that can burn eyes and skin. Sparks fly off from the approved air-supplied respirator. weld. Wear an approved welding helmet fitted with a proper shade of fil- ter lenses to protect your face and eyes when welding or watching HOT PART
Resumen del contenido incluido en la página 7
1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. MOVING PARTS can cause injury. Do not install or place unit on, over, or near Keep away from moving parts such as fans. combustible surfaces. Keep all doors, panels, covers, and guards Do not install unit near flammables. closed and securely in place. Have only qualified persons remove doors, Do not overload building wiring − be sure power supply system is panels, covers, or guards for main
Resumen del contenido incluido en la página 8
1-5. Principal Safety Standards Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, Boulevard, Rexdale, Ontario, Canada M9W 1R3 (phone: from Global Engineering Documents (phone: 1-877-413-5184, website: 800 −463 −6727 or in Toronto 416 −747 −4044, website: www.csa −in- www.global.ihs.com). ternational.org). Practice For Occupational And Educational Eye And Face Protection, Recommended Safe Practices for the Preparation for Welding and Cut- ANSI Standard Z87.1, from American Na
Resumen del contenido incluido en la página 9
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION som _3/05 Avertissement : se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes. 2-1. Symboles utilisés Symbole graphique d’avertissement ! Attention ! Cette pro- cédure comporte des risques possibles ! Les dangers éven- tuels sont représentés par les symboles graphiques joints. Ce groupe de symboles signifie Avertissement ! Attention ! Risques Indique un message de sécurité particulier d’É
Resumen del contenido incluido en la página 10
LES RAYONS D’ARC peuvent entraî- LES ACCUMULATIONS DE GAZ ner des brûlures aux yeux et à la peau. risquent de provoquer des blessures Le rayonnement de l’arc du procédé de soudage ou même la mort. génère des rayons visibles et invisibles intenses Fermer l’alimentation du gaz protecteur en cas (ultraviolets et infrarouges) susceptibles de provo- de non-utilisation. quer des brûlures dans les yeux et sur la peau. Des étincelles sont projetées pendant le soudage. Veiller toujours à bien aérer l
Resumen del contenido incluido en la página 11
2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance Risque D’INCENDIE OU D’EXPLO- DES ORGANES MOBILES peuvent SION. provoquer des blessures. Ne pas placer l’appareil sur, au-dessus ou S’abstenir de toucher des organes mobiles tels à proximité de surfaces inflammables. que des ventilateurs. Ne pas installer l’appareil à proximité de Maintenir fermés et verrouillés les portes, produits inflammables. panneaux, recouvrements et dispositifs de pro
Resumen del contenido incluido en la página 12
2-5. Principales normes de sécurité Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, Boulevard, Rexdale, Ontario, Canada M9W 1R3 (téléphone : de Global Engineering Documents (téléphone : 1-877-413-5184, site In- 800-463-6727 ou à Toronto 416-747-4044, site Internet : ternet : www.global.ihs.com). www.csa-international.org). Practice For Occupational And Educational Eye And Face Protection, Recommended Safe Practices for the Preparation for Welding and Cut- ANSI Standard Z87
Resumen del contenido incluido en la página 13
SECTION 3 − DEFINITIONS 3-1. Warning Label Definitions A. Warning! Watch Out! There are possible hazards as shown by the symbols. B. Drive rolls can injure fingers. AB C C. Welding wire and drive parts are at welding voltage during operation − keep hands and metal objects clear. 1 Electric shock can kill. 1.1 Wear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves. 1.2 Protect yourself from electric shock by insulating yourself 1 1.1 1.2 1.3 from work
Resumen del contenido incluido en la página 14
3-2. Rating Label For CE Products For label location see Section 5-2. S/N: U 24 V 1 50/60 Hz 1 50/60 = IP 21 I = 10.0A 1 U 100 V I = 750 A X 100 % 2 2 = ST-178 794-A 3-3. Symbols And Definitions Some symbols are found only on CE products. Note Amperes Volts Alternating Current Duty Cycle A V X Degree Of Hertz Program Wire Feed Protection IP Hz Jog Output Trigger Line Connection Set Up Sequence Trigger Hold On Trigger Hold Off Purge Press To Set Start Crater Time Preflow Time Postflow Time Read
Resumen del contenido incluido en la página 15
SECTION 4 − INTRODUCTION 4-1. Specifications Type of Welding Power Wire Diameter Welding IP Overall Wire Feed Speed Range Weight Input Power Source Type Range Circuit Rating Rating Dimensions 24 Volts AC Constant Voltage Standard: 50 To 780 ipm .023 To 1/8 in 100 Volts, IP 21 Length: 27 in 45 lb Single-Phase (CV) (1.2 To 19.8 mpm) (0.6 To 3.2 mm) 750 Amperes, (686 mm) (20.4 kg) 10 Amperes DC With 14-Pin 100% Duty Width: 12-1/2 in 50/60 Hertz And Contactor Optional High Speed: 92 To Max Spool Cyc
Resumen del contenido incluido en la página 16
5-2. Rear Panel Connections And Rotating Drive Assembly 1 14-Pin Control Cable − 10 ft (3.0 m) 2 Shielding Gas Valve Fitting Requires fitting with 5/8-18 right- hand threads. Connect customer- supplied gas hose. Shielding gas pressure not to exceed 100 PSI (689 kPa). 3 Weld Cable Terminal 4 Weld Cable 5 Drive Assembly 6 Drive Assembly Rotation 7 Knob 7 Rating Label Location To rotate the drive assembly, loos- 2 en drive assembly rotation knob, rotate drive assembly, and tighten knob. 1 3 4 5 6
Resumen del contenido incluido en la página 17
5-3. 14-Pin Plug Information Pin* Pin Information A 24 volts ac with respect to socket G. B Contact closure to A completes 24 volts ac contactor control circuit. J J A A K K I B G Circuit common for 24 volts ac circuit. L L H N C C +10 volts dc input from power source to wire feeder with respect to socket D. M M G G D D D Remote control circuit common. F F E E E 0 to +10 volts dc output signal from wire feeder to power source with respect to socket D. H Voltage feedback; 0 to +10 volts dc, 1 vol
Resumen del contenido incluido en la página 18
5-6. Installing And Threading Welding Wire Install wire spool. Adjust tension nut so Install wire guides and anti-wear guide. wire is taut when wire feed stops. Install drive rolls. Pressure Indicator Scale Pressure Adjust Rear Pressure Rolls Adjust Front Rolls No Wire Slip Wire Slips NONCONDUCTIVE NONCONDUCTIVE SURFACE SURFACE Drive Rolls Tools Needed: 3/16, 5/64 in Gun Cable 15/16, 3/8 in End Of Liner Be sure that outlet cable has proper size For soft wire or small diameter stainless To
Resumen del contenido incluido en la página 19
5-7. Setting Internal DIP Switches 1 DIP Switch S1 2 DIP Switch S4 (Not For Customer Use) DIP switch S1 allows the user to make a num- ber of choices affecting unit operation. Defining Motor Speed (S1-7 & 8) Switches 7 and 8 allow the user to define whether the motor in use is standard speed (50-780 inches per minute), or high speed (92-1435 inches per minute), or low speed (19-300 inches per minute). When DIP switch positions are changed, the unit must be turned Off and then On again in ord
Resumen del contenido incluido en la página 20
5-8. Power Source Selection Menu 1 Upper Display 2 Lower Display Non-CE Model Shown 1 When the feeder is turned on, the Power Source Selection Menu allows the operator to se- lect a default power source. Selecting a default power source, automatically sets the correct Vmin and Vmax set- Program tings for adjusting the output Volts Time (sec) voltage of the power source. First Time Feeder Is Turned On The feeder automatically goes into Wire Speed Amps the Power Source Selection Menu. 2 Start Th