Resumen del contenido incluido en la página 1
IM794
April, 2006
SP-170T
For use with machine Code Numbers 10981
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be careful.
OPERATOR’S MANUAL
Copyright
Resumen del contenido incluido en la página 2
i i SAFETY WARNING CALIFORNIA PROPOSITION 65 WARNINGS Diesel engine exhaust and some of its constituents The engine exhaust from this product contains are known to the State of California to cause can- chemicals known to the State of California to cause cer, birth defects, and other reproductive harm. cancer, birth defects, or other reproductive harm. The Above For Diesel Engines The Above For Gasoline Engines ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY
Resumen del contenido incluido en la página 3
ii ii SAFETY ELECTRIC SHOCK can ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover kill. plates to protect your eyes from sparks and 3.a. The electrode and work (or ground) circuits the rays of the arc when welding or observing are electrically “hot” when the welder is on. open arc welding. Headshield and filter lens Do not touch these “hot” parts with your bare should conform to ANSI Z87. I standards. skin or wet clothing. Wear dry, hole-free gloves to insulate hands. 4.b. Us
Resumen del contenido incluido en la página 4
iii iii SAFETY WELDING SPARKS can CYLINDER may explode cause fire or explosion. if damaged. 6.a. Remove fire hazards from the welding area. 7.a.Use only compressed gas cylinders If this is not possible, cover them to prevent containing the correct shielding gas for the the welding sparks from starting a fire. process used and properly operating Remember that welding sparks and hot regulators designed for the gas and materials from welding can easily go through small cracks pressure used. All hos
Resumen del contenido incluido en la página 5
iv iv SAFETY PRÉCAUTIONS DE SÛRETÉ 6. Eloigner les matériaux inflammables ou les recouvrir afin de prévenir tout risque d’incendie dû aux étincelles. Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce 7. Quand on ne soude pas, poser la pince à une endroit isolé de manuel aussi bien que les précautions de sûreté générales suiv- la masse. Un court-circuit accidental peut provoquer un antes: échauffement et un risqu
Resumen del contenido incluido en la página 6
v v for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product Thank You ��� as much pride as we have in bringing this product to you! Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment
Resumen del contenido incluido en la página 7
vi vi TABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications ........................................................................................A-1 Safety Precautions.................................................................................................A-2 Identify and Locate Components...........................................................................A-2
Resumen del contenido incluido en la página 8
A-1 A-1 INSTALLATION TECHNICAL SPECIFICATIONS – SP-170T INPUT – SINGLE PHASE ONLY Standard Voltage/Frequency Input Current 230V/60Hz 20 Amps @ Rated Output 208V/60Hz 22 Amps @ Rated Output RATED OUTPUT Duty Cycle Amps Volts at Rated Amperes 20% Duty Cycle @ 230V/60Hz 130 20 20% Duty Cycle @ 208V/60Hz 130 20 OUTPUT Welding Current Range Maximum Open Circuit Voltage Wire Speed Range Rated DC Output: 30 – 170 amps 33 50-400IPM (1.3-10.2m/min) RECOMMENDED INPUT CABLE AND FUSE SIZES Fuse or Output Mo
Resumen del contenido incluido en la página 9
W WE EL LD DIIN NG G A AM MP P R RA AN NG GE E 2 25 5- -12 125 5 A-2 A-2 INSTALLATION FIGURE A.1 SAFETY PRECAUTIONS 1 Read entire installation section before starting 2 installation. WARNING ELECTRIC SHOCK can kill. � Only qualified personnel should perform this installation. � Only personnel that have read and under- stood the SP-170T Operating Manual should install and operate this equipment. � Machine must be plugged into a receptacle which is grounded per any national, local or other
Resumen del contenido incluido en la página 10
A-3 A-3 INSTALLATION 6. Wire Feed Gearbox. SELECT SUITABLE LOCATION 7. Cable Hanger. Locate the welder in a dry location where there is free circulation of clean air into the louvers in the back and 8. Thumbscrew. out the front of the unit. A location that minimizes the amount of smoke and dirt drawn into the rear louvers Refer to the Accessories Section for available optional reduces the chance of dirt accumulation that can block equipment. air passages and cause overheating. Work Clamp Install
Resumen del contenido incluido en la página 11
A-4 A-4 INSTALLATION Work Cable Installation Refer to Figure A.2. NOTE: If .035" or .045" (0.9 mm or 1.2 mm) 1. Open the wire feed section door on the right side of Innershield flux-cored wire is to be used, the appropri- the SP-170T. ate Innershield kit is required. (see ACCESSORIES section) 2. Pass the end of the work cable that has the termi- nal lug with the smaller hole through the Work Connecting Gun Cable to the SP-170T Cable Access Hole (1) in the case front. 1. Refer to Figure A.2. Unpl
Resumen del contenido incluido en la página 12
A-5 A-5 INSTALLATION 2. With the cylinder securely installed, remove the WARNING cylinder cap. Stand to one side away from the out- let and open the cylinder valve very slightly for an CYLINDER may explode if dam- instant. This blows away any dust or dirt which may aged. Keep cylinder upright and have accumulated in the valve outlet. chained to support � Keep cylinder away from areas WARNING where it may be damaged. � Never lift welder with cylinder BE SURE TO KEEP YOUR FACE AWAY FROM THE attach
Resumen del contenido incluido en la página 13
A-6 A-6 INSTALLATION ELECTRICAL INPUT CONNECTION FOR Line Cord Connection RATED OUTPUT A 3 conductor line cord with a 50 amp, 250 volt, three- prong plug (NEMA Type 6-50P) is factory installed. WARNING Connect this plug to a mating grounded receptacle which is connected to an appropriate power supply ELECTRIC SHOCK can kill. per the U.S. National Electric Code and any applicable local codes. � Disconnect input power by removing plug from receptacle Grounding before working inside SP-170T. Type 7
Resumen del contenido incluido en la página 14
B-1 B-1 OPERATION SAFTEY PRECAUTIONS GENERAL DESCRIPTION The SP-170T is a complete semiautomatic constant Read entire operation section before voltage DC portable arc welder. Included is a tap- operating the SP-170T. switch controlled, single phase constant voltage trans- former/rectifier power source and a wire feeder with welding gun for feeding .023" (0.6 mm) through .030" WARNING (0.8 mm) solid steel electrode. Optional kits are avail- able for .035" (0.9 mm) and .045" (1.2 mm) ELECTRIC SHOC
Resumen del contenido incluido en la página 15
B-2 B-2 OPERATION ● Reversible, dual groove drive roll, shipped ready See Figure B.1b. to feed .023"/.025" (0.6 mm) diameter wire. The drive roll is easily reversed to feed .030" (0.8 mm) 4. Circuit Breaker – Protects machine from damage if diameter solid wire and .035" (0.9 mm) flux-cored maximum output is exceeded. Button will extend diameter wire. Optional drive roll included in .045" out when tripped (Manual reset). ® (1.2 mm) Innershield welding kit must be installed to feed .045" (1.2 mm)
Resumen del contenido incluido en la página 16
B-3 B-3 OPERATION To use 4” (100 mm) diameter spools, the 2” (50 mm) diameter spindle must be removed (See Figure B.3). WELDING OPERATIONS Remove the wing nut and spacer at the end of the shaft and remove the outside plastic wire spool spin- SEQUENCE OF OPERATION dle. The spindle can be stored in the wire feed com- partment. A 4” (100 mm) diameter spool is mounted Wire Loading directly on the 5/8” (16 mm) diameter shaft and held in Refer to Figure B.2 and B.3. place with the previously removed
Resumen del contenido incluido en la página 17
B-4 B-4 OPERATION FIGURE B.4 Note: The brake should be adjusted with a spool of wire installed. When properly adjusted it should move freely but not coast. Friction Brake Adjustments 1. With wire spool installed, check free movement and coast of the spool. 2 2. To tighten the brake turn the wing nut clockwise in 1/4 turn increments until coasting stops. Wire from spool. 3. To loosen the brake turn the wing nut counter- 1 clockwise in 1/4 turn increments until the wire spool 4 moves freely with
Resumen del contenido incluido en la página 18
B-5 B-5 OPERATION FIGURE B.7 FIGURE B.6 Contact Tip GUN CABLE Wire Electrode 3/8"– 1/2"(10-13mm) Contact Tip to Work Distance(CTWD) WORKPIECE ARC Making A Weld WORK CLAMP 1. See “Process Guidelines” in this section for selec- 10. When no more welding is to be done, close valve tion of welding wire and shielding gas and for on gas cylinder (if used), momentarily operate gun range of metal thicknesses that can be welded. trigger to release gas pressure, and turn off the SP-170T. 2. See the Applica
Resumen del contenido incluido en la página 19
B-6 B-6 OPERATION The SP-170T is suitable for .035" aluminum wire and – 20 cubic ft per hour (CFH) (7 – 10 I/min) [use 20 – .023"– .035" stainless wire. Refer to Table B.1 for rec- 25 CFH (10 – 12 I/min) when welding out of position ommended procedure settings. (Requires K586-1 or in a drafty location. Deluxe Adjustable kit and K664-2 Aluminum - Stainless Feeding Kit.) 3. Keep the cylinder valve closed, except when using the SP-170T. When finished welding: a) Close the cylinder valve to stop g
Resumen del contenido incluido en la página 20
B-7 B-7 APPLICATION CHART SP-170T