Resumen del contenido incluido en la página 1
Mira Azora Thermostatic Electric Shower
Installation & User Guide
These instructions are to be left with the user
Resumen del contenido incluido en la página 2
Contents Introduction ................................................................................................3 Important Safety Information .....................................................................4 Pack Contents Checklist ...........................................................................6 Specifications ............................................................................................8 Installation Requirements ............................................
Resumen del contenido incluido en la página 3
Introduction Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly. Having done so, keep it handy for future reference. The Mira Azora is a thermostatic electric shower with separate controls for power selection and temperature/flow adjustment. A unique thermostatic valve stabilizes temperature changes caused by water pressure fluctuations. These can result from taps being turned on or off, or a toile
Resumen del contenido incluido en la página 4
Important Safety Information Installation must be carried out in accordance with these instructions, and must be conducted by designated, qualified and competent personnel. Warning! Follow all warnings, cautions and instructions contained in this guide, and on or inside the appliance. . Products manufactured by us are safe and risk-free, provided that they are installed, used and maintained in good working order, in accordance with our instructions and recommendations. . Isolate the el
Resumen del contenido incluido en la página 5
Caution! . Read all of these instructions and retain this guide for later use. . The electrical installation must comply to “BS 767 - Requirements for Electrical Installations”, commonly referred to as the IEE Wiring Regulations - Part 7, or any particular regulations and practices, specified by the local electricity supply company. 3. The plumbing installation must comply with the requirements of UK Water Regulations/Bye-laws (Scotland), Building Regulations or any particular regula
Resumen del contenido incluido en la página 6
Pack Contents Checklist Mira Azora Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included. 1 x Olive 1 x Compression Nut 3 x Fixing Screws 3 x Wall Plugs 1 x Mira Azora Documentation 1 x Installation and User Guide 1 x Installation Template 1 x Installer Checklist 1 x Guarantee Card 6
Resumen del contenido incluido en la página 7
Mira Energise Electric Shower Fittings Tick the appropriate boxes to familiarise yourself with the part names and to con- firm that the parts are included. 2 x Slide Bar Ends 2 x Wall Plugs 2 x End Supports 1 x Handset 1 x Slide Bar 1 x Flexible Hose 1 x Clamp Bracket Assembly 2 x Hose Seals 1 x Soap Dish 1 x Hose Retaining Ring 2 x Fixing Screws 2 x End Plugs Documentation 1 x Installation and User Guide 7
Resumen del contenido incluido en la página 8
Specifications . Plumbing Minimum maintained inlet pressure 70 kPa (0.7 bar). 00 kPa (.0 bar) recommended for satisfactory operation. Maximum static inlet pressure 1000 kPa (10 bar). Minimum static pressure 0 kPa (0. bar) to keep the inlet valve closed. . Electrical The Mira Azora 9.8 kW requires a 45 Amp fuse. The terminal block will accept cable up to 6 mm . 3. Standards and Approvals The Mira Azora complies with all relevant directives for CE marking. Installation Require
Resumen del contenido incluido en la página 9
Avoid layouts where the shower hose will be sharply kinked. This may reduce the life of the hose. A Hose Retaining Ring is supplied to prevent the handset from dropping below the spill-over level of the bath or shower tray, which could lead to contamination from back-siphoning. The supplied Hose Retaining Ring should meet the majority of user requirements for shower installations with flexible outlet fittings. However, there will be occasions when it will not provide a suitable sol
Resumen del contenido incluido en la página 10
. Electrical In a domestic installation, the rating of the electricity supplier’s fuse and the consumer unit must be adequate for the additional demand. All Mira electric showers are high power units, it is essential to contact your electricity supplier to ensure that the supply is adequate for the product. Voltage drop due to local heavy demand will reduce the shower’s performance. The appliance must be earthed by connecting the supply-cable earth conductor to the earth terminal. Su
Resumen del contenido incluido en la página 11
Consumer Unit Double-pole Isolating Switch Installation Installation of Mira Azora Warning! Turn off the electrical and water supplies before proceeding with the installation of the Mira Azora. The electricity must be turned off at the mains and the appropriate circuit fuse removed, if applicable. Note! An installation template is supplied to help you install the Mira Azora. Cover Retaining Screw Remove the three cover retaining screws and the cover. Caution! Handle glass cover assembly w
Resumen del contenido incluido en la página 12
Determine the direction of the inlet water supply: top (falling), bottom (rising), or back inlet . Note! Make sure that the back inlet does not go directly back into the wall. Use a soldered elbow. Swivel the inlet connector assembly to suit. Remove the inlet blanking cap. Avoid trapping the green earth bonding wire. Before fitting the Cover, make sure that the appropriate cutouts have been removed to suit the supply entering the product. Thoroughly flush the mains-fed cold water supply pi
Resumen del contenido incluido en la página 13
Feed cable into Case. Fit Earth sleeve (not supplied) and then strip insulation. Do not twist cable cores. L = BROWN E = GREEN/YELLOW N = BLUE Firmly connect the conductors. Do not exert strain on the terminal block. Cover Retaining Screw Refit the Cover, making sure it is correctly located. Do not overtighten screws. Caution! Handle glass cover assembly with care. Do not use alternative screws to secure the Cover. This can cause internal damage to the appliance. Do not seal around
Resumen del contenido incluido en la página 14
Holes For Cover Retaining Screws Fixing Screw Terminal Block Heater Tank Electrical Supply Cable Inlet Connector Assembly Cold Water Supply Pipe (Bottom Entry) 4
Resumen del contenido incluido en la página 15
Installation of Shower Fittings Decide on a suitable position for the slide bar avoiding buried cables and pipes. Drill the two 7.0 mm fixing holes for the slidebar at 600 mm centres and insert the wall plugs. Assemble the clamp bracket components. Push the plastic slidebar ends into the slidebar. Push the slidebar through the clamp bracket assembly, soapdish and hose retaining ring. Fit the bottom end support loosely to the wall. This will make aligning the top support easier. Insert the
Resumen del contenido incluido en la página 16
Slidebar End End Support Fixing Screw Handset Clamp Bracket Assembly 600 mm Slidebar Soap Dish Hose Retaining Ring End Support Cap 6
Resumen del contenido incluido en la página 17
Commissioning If you are unsure how an electric shower works, please read through the section “User Instructions” before continuing. . . 3. Electrical supply is Turn control to full cold. Turn the water supply fully turned off at the mains. on. 4. 5. 6. Check for water leaks. Set control to ‘I’. Switch on electrical supply. 7. 8. 9. 0 - 5 Secs Water will be at full force Turn the control slowly. Press the ‘Start/Stop’ button. and at a cool temperature. Temperature remains cool and flow is re
Resumen del contenido incluido en la página 18
3. 4. 5 - 0 Secs Set control to ‘III’. The temperature will rise further. 5. 6. Adjust temperature as Press STOP and isolate power. required. Flow rate will adjust automatically. 7. 8. 0 - 5 Secs The shower will purge from its tank Residual water may drain over a few minutes. for a few seconds. Note! A slight hissing sound may be heard from the appliance during operation. High mains water pressure and high shower temperatures will affect the tone. This is quite normal in use. 8
Resumen del contenido incluido en la página 19
User Instructions Read the section “Important Safety Information” first. . . Switch on electrical supply. Press the ‘Start/Stop’ button. 3. 4. Set to desired position. Check water temperature before entering shower. 5. Allow 0 - 5 seconds for any temperature adjustments to reach the handset. 7. 6. Residual water may drain over a few minutes. Press STOP button. Shower will continue to run for a few seconds before stopping. Note! At the end of every shower make sure that the shower head p
Resumen del contenido incluido en la página 20
Spray Action The handset spray head has four different spray actions:- Eco, Start, Soothe and Force. The handset operation is described below. . Eco To access the eco setting, turn the spray plate fully clockwise. Water will flow from the outer set of holes at a reduced flow rate. . Start To access the start setting turn the spray plate anticlockwise until it ‘clicks’ (one click from the eco setting). Water will flow from the outer set of holes. 3. Soothe To