Resumen del contenido incluido en la página 1
Model:
Installers Guide
8000TRD
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
WARNING: IF THE INFORMATION
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
WARNING: IMPROPER INSTALLA-
ING PROPERTY DAMAGE, PER- TION, ADJUSTMENT, ALTERATION,
SONAL INJURY, OR DEATH. SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
- Do not store or use
Resumen del contenido incluido en la página 2
SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully described in the Installing the Fireplace section of ! ! before starting the installation. FAILURE TO the Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result components MAY BE USED. in a possible fire hazard and will void the warranty. This gas fireplace and vent assembly MUST be Prior to the first firing of the fireplace, READ the !
Resumen del contenido incluido en la página 3
TABLE OF CONTENTS Safety and Warning Information ............................................... 2 Service Parts Lists .................................................................... 4 Section 1: Approvals and Codes .............................................. 6 Appliance Certification ................................................................. 6 Installation Codes ........................................................................ 6 u High Altitude Installations ..............
Resumen del contenido incluido en la página 4
8000TRD Service Parts 8000TRD Beginning Manufacturing Date: 6-01 (NG, LP) Exploded Parts Diagram 8000TRD-IPI Beginning Manufacturing Date: 8-01 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ________________ u 19 4 6 8 1 7 5 2 3 18 9 Log Set Assembly 10 17 12 11 14 15 Part number list on following page. * 13 16 La liste des numéros de pièce se * trouve à la page suivante. 4
Resumen del contenido incluido en la página 5
8000TRD Service Parts List / Liste des pièces de rechange IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles po
Resumen del contenido incluido en la página 6
Approvals and Codes High Altitude Installations Appliance Certification u U.L. Listed gas appliances are tested and approved with- The Heat-N-Glo fireplace models discussed in this Installers out requiring changes for elevations from 0 to 2,000 feet in Guide have been tested to certification standards and listed the U. S. A. and in Canada. by the applicable laboratories. When installing this appliance at an elevation above 2,000 feet, it may be necessary to decrease the input rating by Certifica
Resumen del contenido incluido en la página 7
Getting Started Introducing the Heat-N-Glo Gas Fireplaces The Heat-N-Glo Warranty will be voided by, and Heat-N-Glo disclaims any responsibility for, the following actions: Heat-N-Glo direct vent gas fireplaces are designed to oper- ate with all combustion air siphoned from outside of the • Installation of any damaged fireplace or vent system building and all exhaust gases expelled to the outside. component. • Modification of the fireplace or direct vent system. The information contained in this
Resumen del contenido incluido en la página 8
35 1/2 (902mm) 17 3/4 (450mm) 21 1/2 (548mm) ØØ 8 5/8 (219mm) 11 3/4 (297mm) Ø8 5/8 GAS LINE (219mm) ACCESS ELECTRICAL ACCESS 40 3/8 36 3/4 (1026mm) (932mm) 26 7/8 (681mm) 29 1/8 2 1/4 (740mm) (56mm) 3 1/2 43 (1091mm) 8 3/8 (89mm) 9 1/8 (212mm) (233mm) 48 3/8 (1229mm) TOP STANDOFFS TOP VENT COLLARS HOOD RATING PLATE AND LABELS GAS CONTROLS ELECTRICAL ACCESS GAS LINE ACCESS Figure 1. Diagram of the 8000TRD 8
Resumen del contenido incluido en la página 9
1” MIN. (25mm) B A Installing the Fireplace Constructing the Fireplace Chase A chase is a vertical box-like structure built to enclose the gas fireplace and/or its vent system. Vertical vents that run on the outside of a building may be, but are not required to be, installed inside a chase. D E CAUTION: TREATMENT OF FIRESTOP SPACERS AND C CONSTRUCTION OF THE CHASE MAY VARY WITH THE TYPE OF BUILDING. THESE INSTRUCTIONS ARE NOT SUBSTITUTES FOR THE REQUIREMENTS OF LOCAL 1/2” MIN. (13mm) BUILDING CO
Resumen del contenido incluido en la página 10
Step 2. Framing the Fireplace Fireplace framing can be built before or after the fireplace is CAUTION: MEASURE FIREPLACE DIMENSIONS AND set in place. Framing should be positioned to accommo- VERIFY FRAMING METHODS AND WALL COVERING date wall coverings and fireplace facing material. The dia- DETAILS BEFORE FRAMING. gram below shows framing reference dimensions. Shows center of 12” x 12” vent framing holes for top and rear venting. The center of the hole is one (1) inch (25.4mm) above the center
Resumen del contenido incluido en la página 11
6 7/16” (164mm) 8 1/2” (216mm) 8 1/2” 11 5/8” (295mm) (216mm) 11 1/16” 7 3/8” 5 7/8” (149mm) (281mm) 6 1/2” (187mm) 5 1/16” (165mm) (129mm) 8 5/8” 8 5/8” (220mm) (220mm) 11 15/16” (303mm) DV-90D DV-48D DV-36D 11 3/4” (298mm) DV-12D 35 3/4” (908mm) 8 3/4” 47 3/4” (222mm) (1.2m) DV-09D 5 3/4” (146mm) DV-06D NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93mm) AT EACH JOINT. Figure 4. D-Series Direct Vent Component Specifications (5-inch inner pipe / 8 5/8-inch outer pipe) 11 DV-45D
Resumen del contenido incluido en la página 12
Step 3. Installing the Vent System A. Vent System Approvals Identifying Vent Components These models are approved to use D-series direct vent pipe The vent systems installed on this gas fireplace may in- components and terminations (see Figures 4 and 5). Ap- clude one, two, or three 90° elbow assemblies. The rela- proved vent system components are labeled for identifica- tionships of vertical rise to horizontal run in vent configura- tion. This pipe is tested and listed as an approved compo-
Resumen del contenido incluido en la página 13
Flue Restrictor Instructions 1. Remove Exhaust Shield using a 1/4” nut driver by removing the four screws securing it in place (see Figure 7). EXHAUST SHIELD STRAIGHT UP VERTICAL VENTING FLUE RESTRICTOR V (FT.) 40' MAX. (12.4 M) Figure 7 2. Break the Flue Restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 8). BREAK HERE Figure 8. Flue Restrictor Figure 6. Straight Up Vertical Venting NOTE: On vertical venting configurations you may want to
Resumen del contenido incluido en la página 14
4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Fig- HORIZONTAL VENTING ure 9). Kit No. H Max. Run DVK-01D 5. Reinstall the Exhaust Shield. DVK-01TRD 24" (610 mm) 1 2 3 4 5 SETTINGS 1 2 3 4 5 H Figure 9 90-DEGREE ELBOWS 3. Match the amount of vertical you have in the sys- 45-DEGREE ELBOW tem with the chart to find the appropriate position to set the Flue Restrictor. - CHART - Top Vent Top Vent Rear Vent Rear Vent Vertical NG
Resumen del contenido incluido en la página 15
VENTING WITH ONE (1) 90° ELBOW V H 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.4m) V+H=40' MAX. (12.4m) H = 8' MAX. (2.4m) NOTE: On vertical venting configurations where the vertical component is over 10 feet, you may want to install the vertical baffle included in the manual bag assembly to improve flame appearance. Figure 11. Venting with One 90° Elbow VENTING WITH ONE (1)
Resumen del contenido incluido en la página 16
VENTING WITH TWO (2) 90° ELBOWS V H H + H 1 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1m) 3´ MIN. (914 mm) 6´ MAX. (1.86 m) 15´ MAX. (4.65m) 4´ MIN. (1.22 m) 8´ MAX. (2.48 m) 20´ MAX. (6.2m) V+H+H1 = 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m) H+H = 20´ MAX. (6.2m) 1 Figure 13. Venting with Two 90° Elbows o VENTING WITH TWO (2) 90 ELBOWS V FT. H + H (FT.) 1 1' MIN. (305mm) 5´ MAX. (1.52m) 2' MIN. (610mm) 10´ MAX. (3.1m) 3' MI
Resumen del contenido incluido en la página 17
o VENTING WITH TWO (2) 90 ELBOWS V FT. H + H (FT.) 1 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.4m) V+H+H1= 40' MAX. (12.4m) H+H1= 8' MAX. (2.4m) Figure 15. Venting with Two 90° Elbows 17
Resumen del contenido incluido en la página 18
VENTING WITH THREE (3) 90° ELBOWS V H H + H 1 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´MAX. (1.86m) 15´MAX. (4.65m) 4´MIN. (1.22m) 8´MAX. (2.48m) 20´MAX. (6.2m) V +V+H+H = 40´ MAX.(12.4 m) H = 8´MAX.(2.48 m) H+H = 20´MAX.(6.2 m) 1 1 1 V H H + H + H 1 2 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX. (3.1m) 3´MIN. (914mm) 6´MAX. (1.
Resumen del contenido incluido en la página 19
VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.) H 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) NOTE: H + H = 20' MAX. (6.2m) 1 V + V + H + H = 40' MAX. (12.4m) 1 1 H1 V1 V V (FT.) H + H (FT.) 1 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) H +H = 20' MAX. (6.2m) 1 NOTE: V+V +H +H = 40' MAX. (12.4m
Resumen del contenido incluido en la página 20
B. Installing Vent Components 1. Attach the First Vent Component to Starting Collars After determining which set of starting collars will be used To attach the first vent component to the starting collars of (top or rear), follow venting instructions accordingly. the fireplace: Venting Out the Rear Vent • Apply a 3/8 inch (9.5mm) bead of stove cement around Remove the installed rear seal cap from the rear starting the 5 inch (127mm) fireplace starting collar. collars by cutting the strap at ea