Resumen del contenido incluido en la página 1
DiREcT-vENT FiREPLA cE
oWNER’S oPERATioN AND iNSTALLATioN MANUAL
NATURAL GAS “vicT oRiAN” M oDEL (v)v36EN, (v)v42EN SERiES
PRoPANE/LP GAS “vicT oRiAN” M oDEL (v)v36EP, (v)v42EP SERiES
WARNING: If the information in this manual is
WARNING: Improper installation, adjust-
not followed exactly, a fire or explosion may
ment, alteration, service, or maintenance
result causing property damage, personal
can cause injury or property damage. Refer
injury, or loss of life.
to this manual for correct i
Resumen del contenido incluido en la página 2
TAbLE oF coNTENTS Safety Information ........................................................................2 Inspecting Burners......................................................................24 Product Identification ....................................................................3 Cleaning and Maintenance .........................................................25 Local Codes..................................................................................3 Troubleshooting .........
Resumen del contenido incluido en la página 3
SAFETy iNFoRMATioN LocAL coDES Install and use fireplace with care. Follow all local codes. In the Continued absence to local codes, use the current National Fuel Gas Code 12. Do not use this fireplace to cook food or burn paper or other ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Instal- objects. lation Code (Canada). 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) *Available from: in this fireplace. Use only the gas type indicated on fireplace American Nation
Resumen del contenido incluido en la página 4
PRE-iNSTALLATioN PREPARATioN LOCAtION AND SPACE REqUIREMENtS Flush with a wall Determine the safest and most efficient location for your DESA Corner direct-vent fireplace. Make sure that rafters and wall studs are not installation in the way of the venting system. Choose a location where the heat Through exterior wall output is not affected by drafts, air conditioning ducts, windows enclosed in a chase or doors. Figure 2 shows some common locations. Be aware of all restrictions and preca
Resumen del contenido incluido en la página 5
PRE-iNSTALLATioN 1 2 PREPARATioN Continued 3 A Wall FRAMING AND FINISHING 4 Figure 4 shows typical framing of this fireplace. Figure 5 shows fram- B 5 ing for corner installation. All minimum clearances must be met. C 6 For available accessories for this fireplace, see Accessories on page D 29. If you are using a separate combustible mantel piece, refer to E 7 Figure 6 for proper installation height. You can install noncombustible F G mantels at any height above the fireplace. Note: Noncombu
Resumen del contenido incluido en la página 6
V G G V A D E V B L LocATioN oF TERMiNATioN cAP N N H C I B Fixed V V Fixed Closed Openable Closed Openable B F V G V J X B B M A V K X V TERMINATION CAP AIR SUPPLY INLET G GAS METER RESTRICTED AREA X (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony I = clearance to service regulator vent outlet [*72" (182.9 cm) [*12" (30.5 cm) minimum] minimum] B = clearance to window or door that may be opened J = clearance to non-mechanical air supply inlet to building
Resumen del contenido incluido en la página 7
INSt ALLAtION PRECAUtIONS vENTiNG iNSTALLATioN • Wear gloves and safety glasses for protection iNSTRUcTioNS • Use extreme caution when using ladders or when on roof tops • Be aware of electrical wiring locations in walls and ceilings NOtICE: Read these instructions completely before attempting installation. The following actions will void the warranty on your venting system: • Installation of any damaged venting component These models are tested and approved for use with DESA (direct- vent) pi
Resumen del contenido incluido en la página 8
vENTiNG iNSTALLATioN Female Locking Lugs iNSTRUcTioNS Continued 2. Direct vent pipe sections and components are designed with Male special twist-lock connections. Slots t wist-Lock Procedure: The female ends of the pipes have locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes. Push pipe sections together and twist one section clockwise approxi- Figure 8 - Vent Pipe Connections mately one-quarter turn until the sections are
Resumen del contenido incluido en la página 9
vENTiNG iNSTALLATioN iNSTRUcTioNS Minimum Pipe Continued Siding Standoff 1 Overlap 1 / " 4 7. Slide the wall firestop over the vent pipe before connecting horizontal run to vent cap (see Figure 12). Screws 8. Carefully move fireplace, with vent assembly attached, toward Direct Vent wall and insert vent pipe into horizontal termination. The pipe Pipe 1 overlap should be a minimum of 1 /4". Wall Firestop 9. Slide wall firestop against interior wall surface and attach with screws provided. S
Resumen del contenido incluido en la página 10
CORNER INSTALLATION vENTiNG iNSTALLATioN Recommended Applications: iNSTRUcTioNS • Corner ground floor installation Continued • Ground floor installation where pipe vents horizontally through wall (over 12" horizontal pipe) Horizontal t ermination Configurations Figures 14 through 18 show different configurations and alterna- • Basement installation where one foot clearance from ground to tives for venting with horizontal termination. Each figure includes termination is possible a chart with c
Resumen del contenido incluido en la página 11
vENTiNG iNSTALLATioN iNSTRUcTioNS Continued SNORKEL TERMINATION INSTALLATION Recommended Applications: • Installations requiring a vertical rise on building exterior • Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are available for installations requiring a vertical rise on the exterior of the building. If installing snorkel termina- tion below grade, you must provide proper drainage to prevent water from entering snorkel termination (see Figure
Resumen del contenido incluido en la página 12
2. Assemble the desired lengths of pipe and elbows necessary to vENTiNG iNSTALLATioN reach from the fireplace flue up through the firestop. Be sure all iNSTRUcTioNS pipe and elbow connections are fully twist-locked (see Figure 8, page 8). Continued 3. Cut a hole in the roof using the locating hole as a center point. INSt ALLAt ION FOR vERt ICAL t ERMINAt ION (Cover any exposed open vent pipes before cutting hole in roof.) 3 3 The 10 / " x 10 / " hole must be measured on the horizontal; N
Resumen del contenido incluido en la página 13
vENTiNG iNSTALLATioN iNSTRUcTioNS Continued Venting with Two 90° Elbows vertical t ermination Configurations Vertical (V ) Horizontal (H) 1 Figures 21 through 24 show four different configurations for verti- 5' min. 6' max. cal termination. 6' min. 12' max. Venting with Two 90° Elbows 7' min. 18' max. Vertical (V) Horizontal (H ) + 8' min. 20' max. 1 Horizontal (H ) 2 5' min. 2' max. 6' min. 4' max. Note: Install restrictor into inner collar of 7' min. 6' max. fireplace as shown.
Resumen del contenido incluido en la página 14
DESA Terminations vENTiNG iNSTALLATioN Number Description iNSTRUcTioNS 01494 Vertical Round Termination - Galvanized (1) Continued 01495 Horizontal Round Termination - Galvanized (1) 01496 Horizontal Square Termination - Galvanized (1) HIGH ALTITUDE INSTALLATION 01798 Vertical Round High Wind Termination (1) Your DESA direct-vent fireplace has been CSA tested and approved 01800 Horizontal Square High Wind Termination (1) for elevations from 0-2000 feet (USA) and elevations from 0-4500 01801 1
Resumen del contenido incluido en la página 15
Switch Speed Control FiREPLAcE iNSTALLATioN Bracket Continued Blower Plug-In 3. Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 25). Duplex Outlet (Located underneath firebox 4. Be certain that all wire terminals are securely attached to ter- Locknut floor against lower right minals on blower motor and that
Resumen del contenido incluido en la página 16
blower Wiring Diagram FiREPLAcE iNSTALLATioN Continued CAUtION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause im- 3. Place the blower against the lower rear wall of the firebox outer proper and dangerous operation. Verify proper opera- wrapper with the exhaust port directed upward and the thermo- tion after servicing. disc positioned up near the fireplace bottom. The thermodisc must be oriented near the fireplace bottom as shown in Figure 28 Variabl
Resumen del contenido incluido en la página 17
CSA Design-Certified FiREPLAcE iNSTALLATioN Equipment Shutoff Valve Continued with 1/8" NPT Tap* Natural - From For propane/LP connection only, the installer must supply an Gas Meter (5.5" external regulator. The external regulator will reduce incoming W.C. to 10.5" gas pressure. You must reduce incoming gas pressure to between Approved Flexible W.C. Pressure) 11" and 14" of water. If you do not reduce incoming gas pressure, Gas Line Propane/LP fireplace regulator damage could occur.
Resumen del contenido incluido en la página 18
PRESSURE tES t ING FIREPLACE GAS CONNECt IONS FiREPLAcE iNSTALLATioN 1. Open equipment shutoff valve (see Figure 33). Continued 2. Open propane/LP supply tank valve for propane/LP fireplace CHECKING GAS CONNECtIONS or main gas valve located on or near gas meter for natural gas fireplace. WARNING: Test all gas piping and connections for 3. Make sure control knob of fireplace is in the OFF position. leaks after installing or servicing. Correct all leaks at once. 4. Check all joints from equi
Resumen del contenido incluido en la página 19
5. Close glass door frame. Lock latches by placing the bar under the FiREPLAcE iNSTALLATioN tab on door and pushing down and back on latch (see Figure 37). Continued 6. Replace screen/rod assembly by reversing step 1. REMOvING/REPLACING GLASS DOOR 7. Replace louvers by reversing procedure under Removing Lou- ver Panels. CAUtION: Do not operate this fireplace with a bro - ken glass door panel or without the glass door panel Unlock Lock securely in place. For replacement part information see L
Resumen del contenido incluido en la página 20
1 1 2 4 3 INSt ALLING LOGS, LAvA ROCK AND FiREPLAcE iNSTALLATioN GLOWING EMbERS Continued Each log is marked with a number. These numbers will help you 5. Install rear brick panel first. Rest bottom edge of panel on back identify the log when installing. It is very important to install these edge of grate (see Figure 38). logs exactly as instructed. Do not modify logs. Only use logs sup- 6. Install top brick panel by resting on the top of the rear panel. plied with fireplace. Hold the top b