V-400A Series Multifunction Clocks
and Calendar Clocks
Operating and Installation
Instructions
75 The Grove, Ealing LONDON W5 5LL
Email: info @vtx.co.uk
Web: www.vtx.co.uk
Telephone: +44 (0)20 8579 2743
Fax: +44 (0)20 8840 0018
Resumen del contenido incluido en la página 2
Contents Introduction Operating Modes 1 Installation 3 Power Supply Connection 3 External Signal Connection 3 Manual Time Synchronisation 3 Optional Internal Interfaces 3 Guarantee 3 Time and Date Setting 4 Function Programming 6 Programmable Options 7 Special Display Modes 10 EBU/SMPTE Code Formats 11 Serial ASCII Data Formats 12 Up/Down Stopwatch Operation with 402A Stopwatch Controller Introduction 13 Programmable options 14 402A Stopwatch Controller Function Programming 15 402A Stopwatch Con
Resumen del contenido incluido en la página 3
Introduction - 1 Operating Modes The 400A family of electronic digital clocks and calendar clocks allows a wide range of user programmable operating modes as detailed below. To program the required functions please refer to the Function Programming instructions starting on page 6. For a full description of the various program function selection options please refer to pages 7 to 9. • automatic or manual control of display brightness - program function 1. • 12 or 24 hour display selection - progr
Resumen del contenido incluido en la página 4
Introduction - 2 • All models may be programmed to provide one of seven serial RS232 ascii data output messages when used in stand-alone or radio-synchronised modes - program function 9. The output messages may be either every second, after receipt of an ascii `T’ or `t’ - program function 7, selection 4) or on a voltage free switch closure - program function 7, selection 5. The output messages may be at 1200, 2400, 4800, or 9600 baud - program function 10 - , with seven or eight data bits - pro
Resumen del contenido incluido en la página 5
Introduction - 3 be varied to reduce or eliminate unwanted reflections. Please refer to pages 24 to 28 for further mounting information. Power Supply Connection 400A series clocks may be supplied for 230v ac, 110/120v ac, 12v dc, 24v dc or 48v dc. The clock must be connected to the appropriate supply after first verifying the correct voltage by reference to the supply voltage label fixed to or printed on the rear panel of the clock. A connection to the earth line must be made to ensure safe oper
Resumen del contenido incluido en la página 6
Time and Date Setting - 1 A A Enter setting mode Zero seconds or Return to B and step to increment other B normal operation unit values next stage at any stage C C A B C C display of seconds seconds count flashes on/off set to zero A B C C display of minutes minutes count flashes on/off increments A B C C display of hours hours count flashes on/off increments Display for 401 & 420 A B C C month display of months months count flashes on/off increments A B C C day-of-month display of day-of-month
Resumen del contenido incluido en la página 7
Time and Date Setting - 2 A A Enter setting mode Zero seconds or Return to B and step to increment other B normal operation next stage unit values at any stage C C A B C C display of year years count flashes on/off increments A B C C display of month in which seasonal forward month value forward change occurs - display flashes on/off changes - value may be 3, 4, 9, or 10 A B C C display of Sunday in changeover month Sunday value changes on which forward change occurs value may be 1(st), 2(nd), 3
Resumen del contenido incluido en la página 8
Function Programming Enter programming mode B B step to next programming stage after three seconds C A A Return to B normal operation Change program function option at any stage C A B C Program Program function Program function function No. option flashes on/off option changes B C Program Program option selection function No. flashes on/off A B Return to normal operation Note: • Following the display of the last appropriate program option selection the version number of the software will be show
Resumen del contenido incluido en la página 9
Programmable Options - 1 Prog. Function Selection Options Comments No. 1 Display A = Automatic brightness 7 = brightest manual setting ~ = dimmest manual setting 1 2 Hour display 12 = 12 hour display mode 24 = 24 hour display 3 Synchronisation 1 = Stand-alone operation Uses internal crystal mode 2 = one second uni-polar impulse 6-24v 3 = one second alternate polarity impulse 6-24v 4 = half minute uni-polar impulse 6-24v 5 = half minute alternate polarity impulse 6-24v 6 = one minute uni-polar im
Resumen del contenido incluido en la página 10
Programmable Options - 2 Prog. Function Selection Options Comments No. 5 Time zone 1 = Zone number Only available when synchronised to W482 ~ time code from 482 or F 4850 series master clock 6 GPS time offset +13 = Local time difference from UTC in Only required when hours synchronised to 488GPS ~ system -13 External 0 = no external controller 7 controller 1 = 496A stopwatch controller with Only with 401A,420A or mode HH:MM:SS display (HH:MM with 420A) 490A series clocks 2 = 496A stopwatch contr
Resumen del contenido incluido en la página 11
Programmable Options - 3 Prog. Function Selection Options Comments No. 11 Bit length 7 = 7 data bits 8 = 8 data bits 12 Parity O = odd parity E = even parity 13 Hold time 1 = delay in seconds between changes in languages or between time and ~ temperature display 15 14 Seasonal time — = no change-over mode set forwards backwards change-over GB = British change-over pattern 1:00 - 2:00 2:00 - 1:00 mode EU = European change-over pattern 2:00 - 3:00 3:00 - 2:00 US = American change-over pattern 2:00
Resumen del contenido incluido en la página 12
Special Display Formats Special Display Modes Special Display Modes for 450A, 452A, 453A and 454A for 490A.02 and 490A.05 Clocks Calendar Clocks Display mode 1 day-of-week day-of-month month Display mode 2 day-of-year day-of-month month Display mode 3 week-number day-of-month month Display mode 4 day-of-month month year Display mode 5 month day-of-month year Display mode 6 Issue 2.2 10
Resumen del contenido incluido en la página 13
EBU/SMPTE Code Formats 400A series clocks may be programmed to synchronise to EBU/SMPTE time code signals when the optional 404.E interface is fitted. Calendar clocks may be synchronised to one of two date formats. Format 1 (*) is desgined to work with other manufacturers' displays - eg Leitch (TM) whereas Format 2 (**) displays time/date on a video signal in an understandable order. Both formts work with V-401A/V-420A/V-490A Time Displays (ie no date) Application 401, 420 & 490 Clocks Calenda
Resumen del contenido incluido en la página 14
Serial ASCII Data Formats 400A Series clocks and calendar clocks, when fitted with a 404.2 (RS232) or 404.4 (RS485) optional internal interface module, are capable of synchronisation to one of three serial ASCII data message formats and will transmit messages in seven formats. The clock may be programmed to receive or transmit messages at 1200, 2400, 4800 or 9600 baud - program function 10 -, seven or eight data bits - program function 11 - and odd or even parity - program function 12. When prog
Resumen del contenido incluido en la página 15
402A Stopwatch Controller - 1 The 402A Stopwatch Control unit enables a 401A,420A or 490A series clock to be used both as a multifunction stopwatch and a time-of-day clock with the display freely switchable between time-of-day and stopwatch time. The time-of-day count may be synchronised to a wide variety of external time codes, impulses and time signals. Four switches control the stopwatch count, display selection and function programming of the control unit. The operation of these switches is
Resumen del contenido incluido en la página 16
402A Stopwatch Controller -2 Prog. Function Selection Options Comments No. SA Select count 1 = Up from zero Reset switch sets count to direction zero. 2 = Down from a pre-programmed Reset switch sets count to start-time to stop at zero pre-programmed countdown start time. 3 = Down from a pre-programmed Minus sign displayed start-time and then up through zero. during countdown when most significant digit = 0. 4 = Continuously count down to zero with automatic restart from a pre-programmed start t
Resumen del contenido incluido en la página 17
402A Stopwatch Controller - 3 54.0 Switch Control Unit Details 3 core cable 27.0 44.0 to clock 22.0 22.0 12.0 START - HOLD - STOP RESET Panel 102.0 88.0 72.0 cut-out CSW 402A M3 clearance hole Control switch functions in normal operating mode C Time-of-day display selected SW Stopwatch display selected START - HOLD - STOP Refer to page 16 for further information on stopwatch start, stop and display hold functions and programming Stopwatch start, hold or stop function selected RESET or Stopwatc
Resumen del contenido incluido en la página 18
402A Stopwatch Controller - 4 Control switch functions in programming and time-setting mode Enter Programming Mode C SW First display of stopwatch function, countdown start time and time-of-day programming Set clock to time-of-day C RESET Time-of-day time setting display selected Seconds set to zero by the use with seconds flashing on/off of the RESET switch START - HOLD - STOP Refer to pages 4 and 5 for further information on time and date setting. Use the START-STOP-HOLD switch in place of swi
Resumen del contenido incluido en la página 19
402A Stopwatch Controller - 5 Stopwatch Count/Hold function options Count start/stop and display hold function selection Stopwatch timer and display at zero (or pre-programmed down count start time) START - HOLD - STOP Stopwatch timer starts with display following counter 1:04 START - HOLD - STOP Timer stops, Display freezes Display freezes Display freezes Display freezes display shows to show ’SPLIT’ to show ’SPLIT’ to show to show accumulated time time, timer restarts time, timer restarts ’SPL
Resumen del contenido incluido en la página 20
496A Stopwatch Controller - 1 54.0 Switch Control Unit Details 3 core cable 27.0 44.0 to clock 22.0 22.0 12.0 START - STOP Panel 102.0 88.0 72.0 HOLD - RESET cut-out 496A M3 clearance hole The 496A Stopwatch Controller unit enables a 401A, 420A or 490A series clock to be used as a stopwatch. The clock may be programmed to display either : • Hours, minutes and seconds (hours and minutes for 420A series clocks) - program function 7, selection 1. 1 • Minutes, seconds and / th seconds (minutes and s