Resumen del contenido incluido en la página 1
T1 Remote Module Installation
Link Wireless Telephone System
Link 3000 MCU
Part Number: 72-0059-06
Issue E
Resumen del contenido incluido en la página 2
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU NOTICE SpectraLink Corporation has prepared this document for use by SpectraLink personnel and clients. The drawings and specifications contained herein are the property of SpectraLink and shall be neither reproduced in whole or in part without the prior written approval of SpectraLink, nor be implied to grant any license to make, use, or sell equipment manufactured in accordance herewith. SpectraLink reserves
Resumen del contenido incluido en la página 3
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Note concerning the Master Control Unit: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not install
Resumen del contenido incluido en la página 4
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU UL Information This symbol on the nameplate means the product is listed by Underwriter’s Laboratories, Inc. It is designed and manufactured to meet rigid U.L. safety standards against X-radiation, fire, casualty, and electrical hazards. The following are statements required for UL certification, related to safety procedures that must be adhered to during installation. Follow these general precautions
Resumen del contenido incluido en la página 5
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU FCC Information The Master Control Unit Complies with Part 68, FCC Rules FCC Registration Numbers: Link 3000: IYGUSA-7385Q-PX-T Ringer Equivalence: Link 3000: 0.3B SpectraLink Corporation Link 3000 Made in the USA This equipment complies with Part 68 of the FCC Rules. On the back of this equipment is a label that contains, among other information, the FCC Registration Number and Ringer Equivalence Numb
Resumen del contenido incluido en la página 6
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Industry Canada (IC) Notice Notice: The Industry Canada (IC) label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational, and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The department does not guarantee the equipment will operate to the user’s satisfaction. Before ins
Resumen del contenido incluido en la página 7
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Table of Contents 1. ABOUT THIS DOCUMENT 8 1.1 Contacting SpectraLink 8 1.2 Icons Used in this Document 8 1.3 Remote Installation Overview 9 1.4 Remote Installation Steps (Overview) 10 2. SITE PREPARATION 11 2.1 Required Materials Provided by Customer 11 2.2 T1 Configuration Requirements 12 2.3 Check Components 13 3. INSTALL T1 REMOTE MODULE AT LOCAL SITE 14 4. INSTALL SYSTEM AT REMOTE SITE 17 4.1 Surve
Resumen del contenido incluido en la página 8
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 1. About This Document This document explains installation of the SpectraLink Link Wireless Telephone System (Link WTS, MCS300) Remote T1 Module. The installation process connects the Link 3000 MCU Primary Shelf in one location with an Expansion Shelf in a remote location, via T1 facilities. 1.1 Contacting SpectraLink SpectraLink wants every customer to have a successful installation. Please refer questions
Resumen del contenido incluido en la página 9
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 1.3 Remote Installation Overview Networking the Link WTS allows installation of expansion shelves at remote locations. T1 circuits are used to provide the connection from the System Controller shelf to each Remote Expansion shelf. As many as 19 expansion shelves may be supported by the system, and up to 18 of these shelves may be installed in remote locations from the System Controller shelf. The Link WTS
Resumen del contenido incluido en la página 10
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 1.4 Remote Installation Steps (Overview) Follow these steps to install the T1 Remote Module. Detailed instructions for each of these steps are contained in this document and other relevant documents in the Link 3000 MCU System Documentation. 1. Prepare site and check components. 2. Install T1 Remote Module at the local site (location where the Primary Shelf is located.) 3. Connect T1 Remote Module at the loc
Resumen del contenido incluido en la página 11
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 2. Site Preparation The following steps must be completed before installing the system hardware. If the steps are not already completed refer to each individual section for details. 1. At the local site, install and test Primary Shelf and Expansion Shelves. Refer to Link WTS – Link 3000 MCU: Installation (72-0059-01) for information. 2. At the remote site: 2.1 Install a two pair cable to each Base Station a
Resumen del contenido incluido en la página 12
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 2.2 T1 Configuration Requirements T1 circuits will connect expansion shelves directly to the System Controller shelf via the SpectraLink provided Intershelf Junction Panel. The Intershelf Junction Panel is always co-located with the system controller shelf. The following configuration requirements apply to the T1 lines connecting the Link 3000 MCU local and remote shelves. All T1 circuits for networking the
Resumen del contenido incluido en la página 13
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 2.3 Check Components The following items should be at the installation site. Link 3000 MCU Expansion Shelves – (MCS300) – the number of shelves varies depending on the size of the system. Grounding Strap – (in the Link WTS Administration Kit, MKA320) – to protect cards from electrostatic discharge. Expansion Shelf Controller Card – (CSC300) - one card for each Expansion Shelf. This card is installed in
Resumen del contenido incluido en la página 14
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 3. Install T1 Remote Module at Local Site Before installing the hardware at the remote site, the Primary shelf at the local site must have a T1 Remote Module (CRC301) installed. Install one Remote Module for each remote shelf to be installed. Slide the Remote Module into slot 1 or slot 3-12 of any shelf, until the card clicks into place. Tighten the screws at the top and bottom of the card to secure it. Th
Resumen del contenido incluido en la página 15
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Network Clocked T1 Facilities If the T1 facilities are Network Clocked, one T1 Remote Module must be designated as the Master Clock Source. Connect the Sync IN port on this T1 Remote Module to AUX port A on the Intershelf Junction Panel. Note, this shelf must also be designated as the Master Clock in the system configuration. Connect T1 Facilities Connect the RJ48C jack from the CSU port at the local end
Resumen del contenido incluido en la página 16
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU CRC-301 TIMING MASTER IN SYNC To AUX Port on Intershelf Junction Panel for Net Clocked T1 OUT ALARM 1 2 3 4 5 A SYSTEM CONTROLLER RJ45 to Intershelf Junction Panel B SC/A EXPANSION SHELF CONTROLLER SC/B LOS LIKOK DS1 A T1 connection Module 3-7 LOS on remote LIKOK DS1 B T1 connection Module 8-12 on remote Part Number: 72-0059-06-E.doc Page 16
Resumen del contenido incluido en la página 17
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 4. Install System at Remote Site 4.1 Survey Site Check the site to be sure pre-installation work has been completed correctly. This includes: • Location chosen for the shelves is adequate. • Rack (if rack mounted) is properly secured or backboard (if wall mounted) is properly prepared. • Power is available. • Wiring to Base Station locations has been pulled and correctly terminated. • Phone lines for the
Resumen del contenido incluido en la página 18
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Do not install cards until power is connected. 4.3 Connect Power to Shelves SpectraLink recommends that a licensed electrician install the –48V DC power supply and connect power to the shelves. See Link WTS – Link 3000 MCU: Installation, Connect Power to Shelves, for more information. 4.4 Install Cards The shelf diagram below shows a fully loaded Expansion Shelf. Any type of Interface Module can be insta
Resumen del contenido incluido en la página 19
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU T1 Remote Expansion Shelf Interface Modules Module Controller Slot 2 Slots 3-12 RS-232 CRC-301 DISABLE DISABLE DISABLE DISABLE DISABLE DISABLE DISABLE DISABLE DISABLE DISABLE TIMING MASTER NORMAL NORMAL NORMAL NORMAL NORMAL NORMAL NORMAL NORMAL NORMAL NORMAL SC/A (RJ45) IN SYNC SC/B (RJ45) CONN CONN OUT CONN CONN CONN B B B B B ALARM ALARM ALARM ALARM ALARM ALARM ALARM ALARM ALARM ALARM ALARM ALARM 1 1 1 1 1 1 1 1
Resumen del contenido incluido en la página 20
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU The following diagram shows the T1 Remote Module connections at the REMOTE site. CRC-301 TIMING MASTER IN SYNC From sync "Out" if more than one remote shelf OUT To sync "In" if more ALARM than one remote shelf 1 2 3 4 5 A SYSTEM CONTROLLER B SC/A EXPANSION SHELF CONTROLLER RJ-45 to Expansion Shelf SC/A and SC/B SC/B LOS LIKOK DS1 A T1 connection to local LOS Module 3-7 LIKOK DS1 B T1 connection to local Module 8