Resumen del contenido incluido en la página 1
Upflow/ Horizontal Left,
Downflow/ Horizontal Right
Variable Speed
Two Stage Condensing
Gas-Fired Furnace
XV 95
TDH2B060A9V3VA
TUH2B060A9V3VA
TDH2B080A9V3VA
TUH2B080A9V3VA
TDH2B080A9V4VA
TUH2B080A9V4VA
TDH2C100A9V4VA
TUH2C100A9V4VA
TDH2D120A9V5VA
TUH2C100A9V5VA
TUH2D120A9V5VA
Direct Vent with
Variable Speed Blower
Variable Speed Inducer
*DH-A9V-V
*UH-A9V-V
DOWNFLOW
UPFLOW
DOWNFLOW/HORIZONTAL
UPFLOW/HORIZONTAL
PUB. NO. 22-1814-08
Resumen del contenido incluido en la página 2
General Features AIR DELIVERY NATURAL GAS MODELS The variable speed blower motor has Central Heating furnace designs are sufficient airflow for most heating and certified by the American Gas Associa- cooling requirements and will switch tion for both natural and L.P. gas. Limit from heating to cooling speeds on setting and rating data were established demand from room thermostat. The and approved under standard rating blower door safety switch will prevent conditions using American Nat
Resumen del contenido incluido en la página 3
Contents General Features 2 Features and Benefits 4 Standard Equipment 4 Optional Equipment 5 General Data 6-8 TUH2B060A9V3VA TUH2B080A9V3VA TUH2B080A9V4VA TUH2C100A9V4VA TUH2C100A9V5VA TUH2D120A9V5VA TDH2B060A9V3VA TDH2B080A9V3VA TDH2B080A9V4VA TDH2C100A9V4VA TDH2D120A9V5VA Performance Data 9-19 Venting T able 20 Electrical Data 21-24
Resumen del contenido incluido en la página 4
Features and Benefits XV 95 STANDARD EQUIPMENT • Variable Speed Blower Motor • Lite Port™ extended system diag- • Silicon Nitride Igniter with adaptive nostics heat up • Stored fault code history in micro pro- • Variable speed induced draft blower cessor nonvocatile memory • Direct/Non-Direct vent option • Cleanable high velocity filters (upflow • Fused 24 volt control circuit only) • Manual reset burner safety switches • Hinged blower door * • Power supply 115/1/60 • Perfect fit door latches*
Resumen del contenido incluido en la página 5
Features and Benefits XV 95 OPTIONAL EQUIPMENT Thermostat, 2-Stage Heat / 1-Stage Cooling ........................................................................................................... TAYSTAT241 [ ] Thermostat, Media Programmable 2-Stage Heating ..............................................................................................TAYSTAT302C [ ] Thermostat, Mechanical Heating Only With Fan Switch ............................................................................
Resumen del contenido incluido en la página 6
General Data TUH2 PRODUCT SPECIFICATIONS1 1 Product Specifications MODEL TUH2B060A9V3VA TUH2B080A9V3VA TUH2B080A9V4VA TUH2C100A9V4VA TYPE Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal RATINGS 2 1st Stage Input BTUH 39,000 52,000 52,000 65,000 1st Stage Capacity BTUH (ICS) 3 37,830 50,440 50,440 62,855 2nd Stage Input BTUH 60,000 80,000 80,000 100,000 2nd Stage Capacity BTUH (ICS) 3 58,200 77,600 77,600 96,700 AFUE 97 97 97 96.7 Temp. rise (Min.-Max.) °F.
Resumen del contenido incluido en la página 7
General Data TUH2/TDH2 PRODUCT SPECIFICATIONS1 1 PRODUCT SPECIFICATIONS MODEL TUH2C100A9V5VA TUH2D120A9V5VA TDH2B060A9V3VA TDH2B080A9V3VA TYPE Upflow / Horizontal Upflow / Horizontal Downflow / Horizontal Downflow / Horizontal RATINGS 2 1st Stage Input BTUH 65,000 78,000 39,000 52,000 1st Stage Capacity BTUH (ICS) 3 62,855 75,426 37,000 49,400 2nd Stage Input BTUH 100,000 120,000 60,000 80,000 2nd Stage Capacity BTUH (ICS) 3 96,700 116,040 57,000 76,000 AFUE 96.7 96.7 95 95 Temp. rise (Mi
Resumen del contenido incluido en la página 8
General Data TDH2 PRODUCT SPECIFICATIONS1 1 PRODUCT SPECIFICATIONS MODEL TDH2B080A9V4VA TDH2C100A9V4VA TDH2D120A9V5VA TYPE Downflow / Horizontal Downflow / Horizontal Downflow / Horizontal RATINGS 2 1st Stage Input BTUH 52,000 65,000 78,000 1st Stage Capacity BTUH (ICS) 3 49,400 61,750 74,000 2nd Stage Input BTUH 80,000 100,000 120,000 2nd Stage Capacity BTUH (ICS) 3 76,000 95,000 114,000 AFUE 95 95 95 Temp. rise (Min.-Max.) °F. 35 - 65 35 - 65 40 - 70 BLOWER DRIVE DIRECT DIRECT DIRECT Di
Resumen del contenido incluido en la página 9
*UH2B060A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 37,830 2nd Stage Capacity = 58,200 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 600 600 600 600 LOW ON ON TEMP. RISE 57 57 57 57 - WATTS 85 110 155 190 CFM 700 700 700 700 MEDIUM LOW OFF ON TEMP. RISE 49 49 49 49 - HEATING WATTS 90 130 175 210 1ST CFM 775 775 775 775 STAGE NORMAL ** ON OFF TEMP. RISE 44 44 44 44 - WATTS 105 1
Resumen del contenido incluido en la página 10
*UH2B080A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 50,440 2nd Stage Capacity = 77,600 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 800 800 800 800 800 LOW ON ON TEMP. RISE 56 56 56 56 56 WATTS 105 140 180 220 265 CFM 860 880 890 920 910 MEDIUM LOW OFF ON TEMP. RISE 52 51 50 48 49 WATTS 115 165 215 265 320 HEATING 1ST CFM 960 990 1000 1020 1010 STAGE TEMP. RISE NORMAL ** ON
Resumen del contenido incluido en la página 11
*UH2B080A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 50,440 2nd Stage Capacity = 77,600 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 800 800 800 800 800 LOW ON ON TEMP. RISE 56 56 56 56 56 WATTS 105 140 180 220 265 CFM 860 880 890 920 910 MEDIUM LOW OFF ON TEMP. RISE 52 51 50 48 49 HEATING WATTS 115 165 215 265 320 1ST CFM 960 990 1000 1020 1010 STAGE NORMAL ** ON OFF TEMP. RI
Resumen del contenido incluido en la página 12
*UH2C100A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 62,855 2nd Stage Capacity = 96,700 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW8 0.1 0.3 0.5 0.7 0.9 CFM 873 893 900 899 902 LOW ON ON TEMP. RISE 64 63 62 62 62 WATTS 100 145 195 240 290 CFM 971 997 1006 1022 1029 MEDIUM LOW OFF ON TEMP. RISE 58 56 56 55 54 HEATING WATTS 115 170 220 280 335 1ST CFM 1136 1146 1165 1180 1184 STAGE MEDIUM ** ON OFF TEMP
Resumen del contenido incluido en la página 13
*UH2C100A9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 62,855 2nd Stage Capacity = 96,700 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 873 893 900 899 902 LOW ON ON TEMP. RISE 64 63 62 62 62 WATTS 100 145 195 240 290 CFM 971 997 1006 1022 1029 MEDIUM LOW OFF ON TEMP. RISE 58 56 56 55 54 HEATING WATTS 115 170 220 280 335 1ST CFM 1136 1146 1165 1180 1184 STAGE MEDIUM ** ON OFF TEMP
Resumen del contenido incluido en la página 14
*UH2D120A9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 75,426 2nd Stage Capacity = 116,040 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 1090 1120 1080 1070 1010 LOW ON ON TEMP. RISE 62 60 63 63 67 WATTS 165 225 270 310 380 CFM 1210 1200 1200 1180 1160 MEDIUM LOW OFF ON TEMP. RISE 56 56 56 57 58 HEATING WATTS 220 280 330 395 455 1ST STAGE CFM 1340 1360 1370 1380 1330 NORMAL ** ON
Resumen del contenido incluido en la página 15
*DH2B060A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st STAGE CAPACITY = 37,440 2nd STAGE CAPACITY = 57,600 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 600 600 600 600 600 LOW ON ON TEMP. RISE 56 56 56 56 56 WATTS 55 85 120 150 185 CFM 675 675 675 675 675 MEDIUM LOW OFF ON TEMP. RISE 50 50 50 50 50 HEATING WATTS 65 105 140 175 205 1ST CFM 750 750 750 750 750 STAGE NORMAL ** ON OFF TEMP. RISE 45 4
Resumen del contenido incluido en la página 16
*DH2B080A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st STAGE CAPACITY = 49,920 2nd STAGE CAPACITY = 76,800 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 800 800 800 790 LOW ON ON TEMP. RISE 56 56 56 56 - WATTS 130 170 210 245 CFM 900 900 900 900 MEDIUM LOW OFF ON TEMP. RISE 49 49 49 49 - HEATING WATTS 162 210 260 295 1ST CFM 1000 1000 1000 1000 800 STAGE NORMAL ** ON OFF TEMP. RISE 44 44 44 44 56
Resumen del contenido incluido en la página 17
*DH2B080A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st STAGE CAPACITY = 49,400 2nd STAGE CAPACITY = 76,000 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 800 800 800 790 LOW ON ON TEMP. RISE 56 56 56 56 - WATTS 130 170 210 245 CFM 900 900 900 900 MEDIUM LOW OFF ON TEMP. RISE 49 49 49 49 - HEATING WATTS 162 210 260 295 1ST CFM 1000 1000 1000 1000 800 STAGE MEDIUM ** ON OFF TEMP. RISE 44 44 44 44 56
Resumen del contenido incluido en la página 18
*DH2C100A9V4V - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st STAGE CAPACITY = 62,400 2nd STAGE CAPACITY = 96,000 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 923 955 960 958 947 LOW ON ON TEMP. RISE 61 59 58 58 59 WATTS 110 165 210 265 310 CFM 1020 1047 1053 1042 1029 MEDIUM LOW OFF ON TEMP. RISE 55 53 53 54 54 HEATING WATTS 145 190 250 295 350 1ST CFM 1156 1166 1172 1177 1178 STAGE MEDIUM ** ON OFF
Resumen del contenido incluido en la página 19
*DH2D120A9V5V - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st STAGE CAPACITY = 74,880 2nd STAGE CAPACITY = 115,200 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 8 SW 7 0.1 0.3 0.5 0.7 0.9 CFM 1025 1025 1000 1000 1000 LOW ON ON TEMP. RISE 65 65 67 67 67 WATTS 150 200 240 290 340 CFM 1200 1200 1200 1200 1200 MEDIUM LOW OFF ON TEMP. RISE 56 56 56 56 56 HEATING WATTS 230 270 330 390 450 1ST CFM 1350 1350 1350 1350 1350 STAGE NORMAL ** O
Resumen del contenido incluido en la página 20
Maximum Vent Length Table VENT LENGTH TABLE ALTITUDE MAXIMUM TOTAL EQUIVALENT LENGTH IN FEET FOR VENT AND INLET AIR (SEE NOTES) 0-7,000 Feet 2 INCH PIPE 2.5 INCH PIPE 3 or 4 INCH PIPE *UH/DH2B060A9V3VA 200 200 200 *UH/DH2B080A9V3VA 50 120 200 *UH/DH2B080A9V4VA *UH/DH2C100A9V4VA Not Allowed 60 200 *UH2C100A9V5VA *UH/DH2D120A9V5VA Not Allowed Not Allowed 200 7,000-9,500 Feet 2 INCH PIPE 2.5 INCH PIPE 3 or 4 INCH PIPE *UH/DH2B060A9V3VA 100 100 100 *UH/DH2B080A9V3VA 25 60 100 *UH/DH2B080A9V4VA