Resumen del contenido incluido en la página 1
22/04/11
A40
Furnaces
Philco KG7 Series Gas Furnace Features & Benefits
• Category IV Venting System: May be vertically or horizontally vented using either a non-direct vent (1 pipe) or direct
vent (2 pipe) system
• 100% fired and tested: All units and each component are tested on the manufacturing line
• Low boy height: Easy to apply in low ceiling applications, work well with taller high SEER coils
• Best packaging in the industry: Unique corner post design assure product will arriv
Resumen del contenido incluido en la página 2
22/04/11 A40-1 Furnaces 92+ AFUE Single Stage Gas Furnace (High Efficiency) • High efficiency blower kit maximize efficiencies • Multi-speed direct drive blower designed to give a wide range of cooling capacities. Switches on PCB, provides ultra easy motor speed selection. Input Btuh HP -Speed-Type-FLA R410 Coil Model Number Part Number Upflow / Horizontal C6BAX24(C,U)A 38,000 1/3 - 4 - PSC - 4.80 KG7SC038D23A 904639K C6BAX30(C,U)A C6BAX24(C,U)B C6BAX30(C,U)B 54,000 1/2 - 4 - PSC
Resumen del contenido incluido en la página 3
22/04/11 A40-2 Furnaces 95+ AFUE Two Stage Gas Furnace (High Efficiency) • Energy efficient brushless DC (ECM) motor • Control board has connections for twinning Input Btuh HP -Speed-Type-FLA R410 Coil Model Number Part Number Fixed Speed Upflow / Horizontal C6BAX24(C,U)B C6BAX30(C,U)B 60,000 1/2 - FS - BLDC - 6.2 KG7TC060D24B 904727K C6BAX35(C,U)B C6BAX36(C,U)B C6BAX36(C,U)C 80,000 3/4 - FS - BLDC - 8.7 C6BAX37(C,U)C KG7TC080D35C 904728K C6BAX42(C,U)C C6BAX36(C,U)C 100,000 3/
Resumen del contenido incluido en la página 4
22/02/13 A41 Furnaces Frigidaire FG7 Series Gas Furnace Features & Benefits • Category IV Venting System: May be vertically or horizontally vented using either a non-direct vent (1 pipe) or direct vent (2 pipe) system • 100% fired and tested: All units and each component are tested on the manufacturing line • Low boy height: Easy to apply in low ceiling applications, work well with taller high SEER coils • Best packaging in the industry: Unique corner post design assure product will ar
Resumen del contenido incluido en la página 5
22/04/11 A42 Furnaces 92+ AFUE Single Stage Gas Furnace (High Efficiency) • Multi-speed direct drive blower designed to give a wide range of cooling capacities • Switches on PCB, provide ultra easy motor speed selection Input Btuh HP -Speed-Type-FLA R410 Coil Model Number Part Number Upflow / Horizontal C6BAX24(C,U)A 38,000 1/3 - 4 - PSC - 4.80 FG7SC038D23A 904639F C6BAX30(C,U)A C6BAX24(C,U)B C6BAX30(C,U)B 54,000 1/2 - 4 - PSC - 8.20 FG7SC054D24B 904640F C6BAX35(C,U)B C6BAX36(C
Resumen del contenido incluido en la página 6
22/04/11 A43 Furnaces 95+ AFUE Two Stage Gas Furnace (High Efficiency) • iSEER energy efficient brushless DC (ECM) motor gives up to 1 SEER point efficiency gain in cooling • Two stage inducer optimizes efficiency on first stage heat and reduces sound levels Input Btuh HP -Speed-Type-FLA R410 Coil Model Number Part Number Fixed Speed Upflow / Horizontal C6BAX24(C,U)B C6BAX30(C,U)B 60,000 1/2 - FS - BLDC - 6.2 FG7TC060D24B 904727F C6BAX35(C,U)B C6BAX36(C,U)B C6BAX36(C,U)C 80,
Resumen del contenido incluido en la página 7
22/04/11 A44 Furnaces 97+ AFUE iQ Drive® Modulating Gas Furnace (Ultra High Efficiency) • iQ Drive® Modulating Heating Operation Includes: - Modulating gas valve from 100% to 50% input in 5% increments - Time proportioning modulation down to 15% - Variable speed inducer and blower • iQ Drive® thermostat provides modulation down to 15% and is required for furnace operation • iSEER energy efficient brushless DC (ECM) motor gives up to 1 SEER point efficien
Resumen del contenido incluido en la página 8
31/12/10 A45 Furnaces Floor Registers - Plastic • Sleek modern look with rounded corners and blades • Durable plastic construction, will not rust • Smooth, quiet damper adjustment for desired level of air flow • Easy to install, maintenance free Description Brand Part Number 3"x10" Register - White Deflecto RF31003B 3"x10" Register - Taupe Deflecto RF31028B 3"x10" Register - Brown Deflecto RF31036B 4"x10" Register - White Deflecto RF41003B 4"x10" Register - Taupe Deflecto RF41028B
Resumen del contenido incluido en la página 9
15/02/13 A45-1 Furnace Accessories LP Gas Conversion Kits For G6 & L1 Series Furnaces • Designed for Canadian installations. To convert a natural gas furnace to LP/Propane gas for altitudes between 0 to 4,500 feet above sea level, the main gas orifice must be replaced. For higher altitudes (between 2,000 & 4,500 feet above seal level) the input must be de-rated by 10%. This can be done by simply reducing the manifold pressure without changing the gas orifices. • Use on standard &
Resumen del contenido incluido en la página 10
15/02/13 A45-2 Furnaces This Page Left Intentionally Blank Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 Davies Supply Group Ltd. (403) 244-2161 (403) 381-7707 (306) 933-2433
Resumen del contenido incluido en la página 11
14/12/12 A45-3 Furnaces Flue Gas Venting System - System 636™ PVC o • Type BH Class IIA Vent: For use with gas fired appliances producing flue gases of 65 C or less • Complete system fully certified to ULC S636 • White pipe with unique blue certification markings made to SCH 40 dimensions Description Case Part Number Concentric Vent Kits • These "pipe-in-pipe" kits allow for both exhaust and intake pipes to 2" Flue Gas Venting System penetrate the roof or side wall through only one
Resumen del contenido incluido en la página 12
14/12/12 A45-4 Furnaces Condensate Water Neutralizer Kit For High Efficient Gas Furnaces • Inline cartridge that will raise or neutralize the pH level of the condensate water • Limestone neutralizer material should be changed yearly Description Includes Part Number 2" Inline cartridge 1/2" ID vinyl tubing, hose clamps & mounting ties 902377 J Hooks (Furnace Venting Accessory) Description Part Number 2" x 7 1/2" DWV Swiveling J Hook (Plastic) 515-J2000 3" x 7 1/2" DWV Swiveling J H
Resumen del contenido incluido en la página 13
11/06/10 A45-5 Furnaces Variable Speed Blower Kits for Frigidaire "G6 & L1" Gas Furnaces • 904231 kit fits all G6/L1 series gas furnaces with an "A" width cabinet. May be configured for air conditioning/heat pump airflows from 1 1/2 to 3 tons nominal capacity. • 904075 kit fits all G6 (RA,RC,RK&RL) series gas furnaces with "B" & "C" width cabinets. May be field configured for air conditioning/ heat pump airflows from 2 to 5 tons nominal capacity. • Designed to maximize system eff
Resumen del contenido incluido en la página 14
06/09/13 A45-6 Furnaces This Page Left Intentionally Blank Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 Davies Supply Group Ltd. (403) 244-2161 (403) 381-7707 (306) 933-2433
Resumen del contenido incluido en la página 15
18/02/11 A45-7 Furnaces Oil-Fired Forced Air Furnaces With Burner • 80+ AFUE • Warranty: Limited lifetime on 14 gauge heat exchanger; 1 year parts • LFR Models: Chamber-less unit is designed for compact installations requiring front or rear flue. The unit is approved for chimney or balanced flue venting and is ideal for electric conversions. The large filter rack can be placed on either side, bottom or rear • LFR-VSM Models: With the Newmac Ultratech™ Motor Control. This system incorp
Resumen del contenido incluido en la página 16
15/01/10 A45-8 Furnaces Combination Oil/Gas & Wood Furnace With Beckett AFG Burner • Separate combustion chamber for oil/gas • Extra large brick lined firebox • Pre-heated combustion air is introduced by a thermostatically con- trolled draft system • Disposable air filters • Warranty: 10 year limited on the heat exchanger • CL85/95 Model: Automatic switching from wood to oil • CL86/96C Model: Automatic switching from wood to oil, separate thermostats & large fire door. Burns wood wi