Resumen del contenido incluido en la página 1
LRG-55
Scorpion™ 55 RG
USER MANUAL
th
CHAUVET, 3000 N 29 Ct, Hollywood, FL 33020 U.S.A
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
Resumen del contenido incluido en la página 2
TABLE OF CONTENT BEFORE YOU BEGIN.................................................................................................................................... 3 WHAT IS INCLUDED......................................................................................................................................... 3 UNPACKING INSTRUCTIONS............................................................................................................................. 3 AC POWER .............
Resumen del contenido incluido en la página 3
BEFORE YOU BEGIN What is included 1 x Scorpion™ 55 RG User Manual Warranty Card Power cord Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials.
Resumen del contenido incluido en la página 4
Introduction Safety Instructions Please read these instructions carefully, which includes important information about the installation, usage and maintenance? • Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. • Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fi
Resumen del contenido incluido en la página 5
INTRODUCTION You may notice that both the red and green beams coming out of the projector are larger than the 4.95mW projectors. There is a very distinct reason for this. Unlike 4.95mW projectors the output of the CHAUVET laser projectors with Fatbeam™ technology inside outputs <20mW for each beam. Normally outputs greater than 4.95mW require a variance from the FDA. This product has been designed to meet a special classification of ClassIIIR. Under this classification with the Fatbeam™
Resumen del contenido incluido en la página 6
Product Overview DANGER: Laser Radiation emitted from this aperture. Before connecting the unit to AC power, make certain that the front aperture is pointed away from you or others. Sound Power Switch Dipswitch settings for DMX Sensitivity addressing & Knob other functions Fan Switch selectable power DMX AC Power Input connectors LRG-55 User Manual 6 11/14/2007/18:46
Resumen del contenido incluido en la página 7
AC Power Connection: The unit is supplied with a power plug appropriate to its voltage and destination. Should any other connections be required they must be carried out with the following configuration. Earth = Green/Yellow cable Neutral = Blue cable Live = Brown cable General Instructions Please read carefully and thoroughly the contents of this manual before operating the Laser system. These instructions contain important safety information regarding the use and maintenance of
Resumen del contenido incluido en la página 8
COMPLIANCE STATEMENT Your LRG-55 complies with FDA/CDRH 21CFR1040 and Laser Notice 50 as well as IEC 60825- 1:2003. Due to a unique optic design, this product does not exceed output powers that exceed its classification and output levels government agencies have determined to be appropriate for the products function. Laser Safety and Compliance Information This product is manufactured to comply with the IEC 60825-1 and in accordance with U.S. Food and Drug Administrations (FDA) Standar
Resumen del contenido incluido en la página 9
Proper Usage This unit has been designed to be hung. It is recommended that, for safety purposes, your lighting effect are properly mounted using a suitable hanging clamp and safety cable. CHAUVET offers a range of items, which are ideal for safe mounting. It is the responsibility of the manufacturer to provide useful instruction on the proper use of this product. According to FDA Regulations you should operate the product in the fashion illustrated below. CAUTION: Use of controls, ad
Resumen del contenido incluido en la página 10
256 256 128 128 64 64 32 32 16 16 8 8 4 4 2 2 1 1 DMX Mode In this mode you will be able to control each individual trait of the fixture independently. The LRG-55 occupies 8 channels of DMX control. For detailed listing of the DMX channel values refer to the Appendix section. SETTING THE STARTING ADDRESS This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start address" from 1 to 511. A fixture requiring one or more channels for control begins
Resumen del contenido incluido en la página 11
Operation Stand-Alone Operation (Sound_Active, Auto Mode): This mode allows a single unit to run to the beat of the music, or the unit will auto change in Auto Mode. 1) Set dipswitches position to Sound Active or Auto Mode. Mode Dipswitches Sound Active 10 = Off, 11 = Off, 12 = Off Auto Mode 10 = Off, 11 = Off, 12 = On 2) The unit will react to the low frequencies of music via the internal microphone in Sound Active mode, or the unit will auto change in Auto Mode. 3) Use the
Resumen del contenido incluido en la página 12
Universal DMX Control (DMX Mode): This mode allows you to use a universal DMX-512 controller to control lasers operation and effects. 1) To control your fixture in DMX Mode use standard XLR DMX cable to daisy chain your units together via the XLR connector on the rear of the units. For long cable runs we suggest a terminator at the last fixture. Mode Dipswitches DMX mode 10 = On, 11 = Off, 12 = On 2) Assign a DMX address to the unit by following the dipswitch chart. 3) Use DMX cont
Resumen del contenido incluido en la página 13
APPENDIX DMX Primer There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required. Choosing a start address should be planned in adva
Resumen del contenido incluido en la página 14
DMX Quick Reference Chart DMX Address Quick Reference Chart Dip Switch Position DMX DIP SWITCH #9 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 SET 0=OFF #8 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 1=ON #7 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 X=OFF or ON #6 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 #1 #2 #3 #4 #5 0 0 0 0 0 32 64 96 128 160 192 224 256 288 320 352 384 416 448 480 1 0 0 0 0 1 33 65 97 129 161 193 225 257 289 321 353 385 417 449 481 0 1 0 0 0 2 34 66 98 130 162 194 226 258 290 322 354 386 418 450 482
Resumen del contenido incluido en la página 15
DMX Channel Values Channel Value Function Mode 000 010 Laser off 1 011 120 Dynamic Patterns 121 250 Static Patterns 251 255 Sound Active Mode Pattern Selection 2 000 255 Static Patterns – Dynamic Patterns X Position 3 000 255 Left > Right Y Position 4 000 255 Top > Bottom Scan Speed 5 000 255 Fast > Slow Dynamic Pattern Speed Control 6 000 255 Fast > Slow / See page 16 Static Pattern Size Control 7 000 255 Small > Big / See page 17 Color 000 100 Gr
Resumen del contenido incluido en la página 16
Dynamic Patterns & DMX Values LRG-55 User Manual 16 11/14/2007/18:46
Resumen del contenido incluido en la página 17
Static Patterns & DMX Values LRG-55 U LRG-55 Us ser Man er Manu ual al 17 17 11/14/20 11/14/2007/18: 07/18:46 46
Resumen del contenido incluido en la página 18
General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance. Unplug fixture from power. Use a vacu
Resumen del contenido incluido en la página 19
Technical Specifications WEIGHT & DIMENSIONS Length......................................................................................................................... 256 mm (10.08 in) Width .......................................................................................................................... 270 mm (10.63 in) Height ........................................................................................................................... 130 mm (5.12 in) Weigh