INSTRUCTION 
 
 
MANUAL 
Model 4040A 
MANUAL DE INSTRUCCIÓN 
MODELO 4040A 
 
 
20 MHz SWEEP/FUNCTION 
GENERATOR 
with FREQUENCY COUNTER 
 
20 MHz GENERADOR DE 
BARRIDO/FUNCIONES CON 
CONTADOR DE FRECUENCIA 
 
 
 
                                                                                                                                                                                                                                                                                             
                    
                    Resumen del contenido incluido en la página 2 
                    
                                TEST INSTRUMENT SAFETY    WARNING    Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must sometimes be  performed where exposed voltage is present. An electrical shock causing 10 milliamps of current to pass through the heart will stop  most human heartbeats. Voltage as low as 35 volts dc or ac rms should be considered dangerous and hazardous since it can produce a  lethal current under certain conditions. Higher voltages pose 
                    
                    Resumen del contenido incluido en la página 3 
                    
                        Instruction Manual   for Model 4040A  20 MHz     SWEEP/FUNCTION GENERATOR  with FREQUENCY COUNTER    22820 Savi Ranch Parkway •  Yorba Linda, CA 92887       3                                                                                                                                                                                                                                                                                                                                                      
                    
                    Resumen del contenido incluido en la página 4 
                    
                          TABLE OF CONTENTS    TEST INSTRUMENT SAFETY ...........inside front cover Voltage Controlled Frequency Operation ........................17    INTRODUCTION ........................................................ 5 Sweep Operation............................................................ 18    SPECIFICATIONS ...................................................... 6 Use of Frequency Counter with External Signals ............ 18      CONTROLS AND INDICATORS ................................ 8 Ou
                    
                    Resumen del contenido incluido en la página 5 
                    
                        
                    
                    Resumen del contenido incluido en la página 6 
                    
                          SPECIFICATIONS    FREQUENCY CHARACTERISTICS      Waveforms: Sine, Square, Triangle, ± Pulse, ± Ramp  Square Wave    Range: 0.2Hz to 20MHZ in 8 ranges  Symmetry:  ≤2% 0.2Hz to 100kHz  Resolution:    Rise Time:  ≤30ns (Typical)  Tuning Range: Coarse: 10:1, Fine: ± 5% of Coarse   Overshoot &      Setting  Undershoot  ≤5%    Variable Duty Cycle 15:85:15 Continuously Variable      Operating Modes Normal, Sweep, VCG, AM, FM, Burst  TRIANGLE WAVE  Frequency  Stability: The output will change less tha
                    
                    Resumen del contenido incluido en la página 7 
                    
                        SPECIFICATIONS    Repetition Rate: 0.5Hz to 50Hz, internal or DC to  SWEEP OPERATION   500kHz, external  Mode: LIN / LOG   Burst Frequency: Determined by the main generator  Width: 100:1, Continuously variable   frequency setting. Tone burst is in  Rate: 20mS to 2 sec, continuously    integral  cycles of frequency being   variable   gated.  Sweep Output: 0 to 2V    FREQUENCY COUNTER  Start/Stop   Accuracy: Time Base Accuracy ±1  Frequencies: Adjustable     count  AM MODULATION CHARACTERISTICS  T
                    
                    Resumen del contenido incluido en la página 8 
                    
                        
                    
                    Resumen del contenido incluido en la página 9 
                    
                              Figure 1. Model 4040A Front Panel.      19 BURST OFF/ON Switch. Selects external or  17. BURST WIDTH Control. Adjusts the duty   internal burst gate. Continuous output is obtained  cycle of the internal burst gate.  with switch in the OFF position and no external  18. % MODULATION Control. Adjusts the    burst gate is applied.  percentage of AM or FM modulation.   9                                                                                                                              
                    
                    Resumen del contenido incluido en la página 10 
                    
                            CONTROLS AND INDICATORS  27.  SWEEP STOP Control. Adjusts the ending sweep    20. .START/STOP Switch. Enables adjustment of the starting  frequency.    and stopping sweep frequencies. The actual adjustment is  28. COARSE FREQUENCY Control. Coarse adjustment    performed by the SWEEP START and SWEEP STOP  of the output frequency from 0.1 to 1 times the selected    controls (29 and 27). START/STOP selection is enabled  range.    only when the SET/RUN switch (21) is set to SET.  29. SWEEP START
                    
                    Resumen del contenido incluido en la página 11 
                    
                          OPERATING INSTRUCTIONS    The B&K Precision Model 4040A Sweep/Function Generator is a  5. Rotate the COARSE (28) frequency control to quickly set the  versatile instrument, capable of producing a variety of output  output frequency to the approximate desired value. The FINE  waveforms over a broad range of frequencies. To gain a working  (26) frequency control can then be used to easily set the output    familiarity with the unit, it is recommended that it be connected  to the specific desired
                    
                    Resumen del contenido incluido en la página 12 
                    
                          OPERATING INSTRUCTIONS      6. Adjust the amplitude of the output as desired using the  OUTPUT LEVEL control (10). Rotation of this control  varies the amplitude from maximum to 20dB below  maximum. An additional attenuation of -20dB is available by  pushing in the -20dB switch (5). The attenuation factors can  be combined for a total of -40dB. The maximum signal level  is 10V p-p (into 50 Ω).  7. A DC component can be added to the output signal by  pushing in the DC OFFSET switch (4) to enabl
                    
                    Resumen del contenido incluido en la página 13 
                    
                        OPERATING INSTRUCTIONS    4. When the 2 Hz range is selected, the gate time is 10 seconds and    the display is updated once every 10 seconds. The result of a    frequency change will not be displayed until 10 seconds later.    Adjust the frequency in progressively smaller steps, waiting for  the display to update until the desired frequency is obtained.  5. When outputting square waves or when using the TTL output,  terminate the cable into 50 Ω to minimize ringing. Also, keep  cables as short 
                    
                    Resumen del contenido incluido en la página 14 
                    
                        OPERATING INSTRUCTIONS        3. Varying the duty cycle setting results in a slight change in                                                                         frequency. Adjust the COARSE and FINE frequency controls         as required.    BURST OPERATION  In gated burst mode of operation, the generator output is switched  on and off (gated), either by an internally generated signal or by an  externally applied signal. Both the repetition rate and the duty cycle  are variable. Fig. 5 illu
                    
                    Resumen del contenido incluido en la página 15 
                    
                          OPERATING INSTRUCTIONS    3. With BURST ON/OFF switch in OFF position, apply a   AM OPERATION TTL gating signal of the proper width to the front panel   The output of Model 4040A can be amplitude-modulated,  BURST INPUT jack.  either by the internal 1 kHz signal, or by an external signal    applied to the VCG/MOD INPUT jack.  Considerations      Internal    l. Make sure the tone burst and entire off period is viewed      when setting the repetition rate. The visible portion of the  1. Set the 
                    
                    Resumen del contenido incluido en la página 16 
                    
                            OPERATING INSTRUCTIONS    3. Place the EXT MODULATION switch in the released position.  4. Connect a suitable modulating signal to the VCG/MOD INPUT jack on  the front panel.  5. Adjust the modulation level as described previously.  FM OPERATION    The output of the Model 4040 can be frequency-modulated, either by the  internal 1 kHz internal signal or by an external signal applied to the front  panel VCG/MOD INPUT jack.  Internal    1. Set the carrier frequency using the main FREQUENCY cont
                    
                    Resumen del contenido incluido en la página 17 
                    
                            OPERATING INSTRUCTIONS    4. Connect a suitable modulation signal to the VCG/MOD  will vary the frequency which is pre-selected by the range    INPUT jack on the front panel.  switches and the frequency controls. Applying    5. Adjust the amplitude and frequency of the external  approximately +l0 V with the COARSE control at full    signal as required. Typically, a signal less than 10V p- clockwise decreases the output frequency by about 100    p will provide 10% modulation of the carrier.  
                    
                    Resumen del contenido incluido en la página 18 
                    
                              OPERATING INSTRUCTIONS   SWEEP OPERATION   USE OF FREQUENCY COUNTER WITH EXTERNAL   SIGNALS        1. Select LINEAR sweep by leaving the SWEEP LIN/LOG switch      (23) in the released position or select LOG sweep by engaging the    The frequency counter display in the Model 4040 is  SWEEP LIN/LOG switch.    normally used to monitor the internally generated output.  2. Rotate COARSE FREQUENCY Control to minimum (CCW).    However, it can also be used as a stand-alone frequency    3. Engage t
                    
                    Resumen del contenido incluido en la página 19 
                    
                          OPERATING INSTRUCTIONS               OUTPUT PROTECTION CONSIDERATIONS    Use care when connecting the function generator output to a  signal injection point. Excessive voltage at the point of signal  injection of the function generator can cause internal damage.  Under normal operation, the generator output should never be  connected to an external voltage other than low dc values that can  be matched with the DC OFFSET control. The Model 4040 is                                overload protect
                    
                    Resumen del contenido incluido en la página 20 
                    
                            MAINTENANCE        INSTRUMENT REPAIR SERVICE   WARNING      The following instructions are for use by qualified service personnel    Because of the specialized skills and test equipment required for  only.  To avoid electrical shock, do not perform servicing other than  instrument repair and calibration, many customers prefer to rely  contain ed in the operating instructions unless you are qualified to  upon B+K PRECISION for this service. We maintain a network  do so.    of B+K PRECISION au