Resumen del contenido incluido en la página 1
PR-G3200M, PR-G5500M AND
PR-G7500M
GENERATORS
Operator’s Manual 1
Resumen del contenido incluido en la página 2
INTRODUCTION THANK YOU for purchasing a John Deere product. The SERIAL NUMBER is located in the Specification or Identification Numbers section. Accurately record all READ THIS MANUAL carefully to learn how to operate the numbers to help in tracing the machine should it be and service your machine correctly. Failure to do so stolen. Your dealer also needs these numbers when you could result in personal injury or equipment damage. This order parts. File the identification numbers in a
Resumen del contenido incluido en la página 3
CONTENTS Page Safety ............................................................ 4 Safety Signs .................................................. 5 Controls ...................................................... 12 Preparing the Generator .............................. 11 Operation ..................................................... 16 Troubleshooting ........................................... 19 Service ......................................................... 20 Storage
Resumen del contenido incluido en la página 4
SAFETY RECOGNIZE SAFETY INFORMATION This is the safety alert symbol. When you see this sym- bol on your machine or in this manual, be alert to the potential for personal injury. Follow recommended precautions and safe operating practices. UNDERSTAND SIGNAL WORDS A signal word--DANGER, WARNING or CAUTION--is used with the safety-alert symbol. DANGER identifies the most serious hazards. DANGER or WARNING safety signs are located near specific hazards. General precautions are listed on CAU
Resumen del contenido incluido en la página 5
CARBON MONOXIDE - POISONOUS GAS Use generator outdoors, away from open windows, vents, or doors. Generator exhaust contains carbon monoxide - a poisonous gas that can kill you. You CAN NOT smell or see this gas. Never use a generator in enclosed or partially-enclosed spaces. Generators can produce high levels of carbon monoxide very quickly. When you use a portable generator, remember that you cannot smell or see carbon monoxide. Even if you can’t smell exhaust fumes, you may still be expo
Resumen del contenido incluido en la página 6
SAFETY WARNING WHEN REFUELING Gasoline is extremely flammable and its vapors can explode if ignited. Observe all safety regulations for the safe handling of fuel. Handle fuel in safety containers. If the container does not have a spout, use a fun- nel. Do not overfill the fuel tank, leave room for the fuel to expand. Do not refill fuel tank while the engine is running. Before refueling the generator, turn it off and let it cool down. Gasoline spilled on hot engine parts could ignite. Fill the
Resumen del contenido incluido en la página 7
ELECTRICAL HAZARDS This product must be grounded. It has permanent conductor between the generator (stator winding) and the frame. If it should malfunction or breakdown, grounding provides a path of least resistance for elec- tric current to reduce the risk of electric shock. DANGER - IMPROPER CONNECTION OF THE EQUIPMENT- GROUNDING CONDUCTOR CAN RESULT IN A RISK OF ELECTROCUTION. CHECK WITH A QUALIFIED ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN DOUBT AS TO WHETHER THE UNIT IS PROPERLY
Resumen del contenido incluido en la página 8
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF INJURY, READ THIS OPERATOR’S MANUAL COMPLETELY BEFORE USING. WHEN USING THIS PRODUCT, THE FOLLOWING BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED: 1. Read all the instructions before using the product. 2. This product is equipped with a Ground Fault CircuitInterrupter (GFCI) in the power cord to reduce the risk of electrical shock. If replacement of the plug or cord is needed, use only identical replacement parts. 3. Do not allow
Resumen del contenido incluido en la página 9
WEAR PROTECTIVE CLOTHING Wear close fitting clothing and safety equipment appro- priate to the job. Wear a suitable hearing protective device such as ear- muffs or earplugs to protect against objectionable or uncomfortable loud noises. Operating equipment safely requires the full attention of the operator. Do not wear radio or music headphones while operating machine. PREPARE FOR EMERGENCIES Keep a first aid kit and fire extinguisher handy. Keep emergency numbers for doctors, ambulance ser- v
Resumen del contenido incluido en la página 10
SAFETY SIGNS GND 34-0889 062104-ENG. 34-0889 W ARNING A VERTISSEMENT ADVERTENCIA POISONOUS GAS EXPLOSIVE FUEL SHOCK GAZ TOXIQUE CARBURANT EXPLOSIF DÉCHARGE GASES VENENOSOS COMESTIBLE EXPLOSIVO DESCARGA This product gives off carbon monoxide, a Gasoline is extremely flammable and its A generator is a potential shock hazard Ce produit émet de l'oxyde de carbone, un gaz L'essence est extrêmement inflammable et ses Un génerateur pose un danger de décharge électrique qui Este producto despide monóxid
Resumen del contenido incluido en la página 11
SAFETY SIGNS SAFETY SIGNS 34-1590 34-1561 (PR-G7500M) 34-1562 (PR-G5500M) 34-1574 (PR-G5500M) Operator’s Manual 11
Resumen del contenido incluido en la página 12
CONTROLS CONTROLS FOR C B A D E B C D B C D C -- Fuel Cap E -- Oil Drain A -- Control Panel B -- Fuel Tank D-- Oil Dipstick 12 Operator’s Manual
Resumen del contenido incluido en la página 13
PREPARING THE GENERATOR GROUNDING INSTRUCTIONS This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. DANGER - IMPROPER CONNECTION OF THE EQUIPMENT-GROUNDING CONDUCTOR CAN RESULT IN A RISK OF ELECTROCUTION. CHECK WITH A QUALIFIED ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN DOUBT AS TO WHETHER THE UNIT IS PROPERLY GROUNDED. The wing nut and ground terminal on the fram
Resumen del contenido incluido en la página 14
PREPARING THE GENERATOR ENGINE OIL TEMPERATURE CHART Use oil viscosity based on the expected air temperature range during the period between oil changes. Use a high quality detergent oil with API classifications of SJ or higher. Check oil level before each operation and ensure that it is maintained. CAUTION: THIS ENGINE CRANKCASE IS NOT FILLED WITH OIL AT THE FACTORY, SO BE SURE TO FILL IT BEFORE OPERATING THE ENGINE. ENGINE OIL CAPACITY MODEL # Liters Quart Ounces OIL GAUGE PR-G3200M 0.
Resumen del contenido incluido en la página 15
PREPARING THE GENERATOR GENERAL RECOMMENDATIONS • Purchase gasoline in small quantities and store in clean, approved containers. • To minimize gum deposits in your fuel system and to insure easy starting, do not use gasoline left over from the previous season. • Do not add oil to the gasoline. FUEL TYPE • For best results use only clean, fresh, unleaded gasoline with a pump sticker octane rating of 87 or higher. • Unleaded gasoline is recommended as it leaves less combustion chamb
Resumen del contenido incluido en la página 16
OPERATION OPERATION RECOIL START NOTE: Read Operator’s Manual carefully before operating this unit. Always make sure the unit is level and properly grounded. Check engine oil before starting. 1. Open fuel valve on fuel tank. (See Fig. 3) 2. Move choke lever to full choke. If re-starting a warm engine, the choke should be left in the off position. (See Fig. 4) 3. Turn the engine ignition switch to the ON position. 4. Pull recoil to start engine. (Fig. 3) 5. Once engine has started, slowly mov
Resumen del contenido incluido en la página 17
OPERATING THE GENERATOR CONTROLS CONTROL PANEL: The generators are equipped with the following items: PR-G3200M: • Circuit Breaker • One 125 Volt, 20 Amp, Duplex (2 outlets), GFCI protected receptacles. PR-G5500M: • Circuit Breakers • Two 125 Volt, 20 Amp, Duplex (2 outlets), GFCI protected receptacles. • One 125/250 Volt, 20 Amp, Locking Type Receptacle. PR-G7500M: • Circuit Breakers • Two 125 Volt, 20 Amp, Duplex (2 outlets), GFCI protected receptacles. • One 125/250 Volt, 30 Amp,
Resumen del contenido incluido en la página 18
OPERATING THE GENERATOR CONTROLS CABLE SIZE: Equipment damage can result from low voltage. Therefore, to prevent excessive voltage drop between the generator and the equipment, the cable should be of adequate gauge for the length used. The cable selection chart gives the maximum cable lengths for various gauges of wire which can adequately carry the loads shown. CURRENT LOAD IN WATTS MAXIMUM CABLE LENGTH (FEET) IN AMPS 120 VOLTS 240 VOLTS #8 WIRE #10 WIRE #12 WIRE #14 WIRE
Resumen del contenido incluido en la página 19
TROUBLESHOOTING SYMPTOM PROBLEM SOLUTION Engine will not start. Engine switch is off. Turn engine switch to the ON position. Fuel Tank empty. Fill tank per instructions in this manual. Fuel Valve is off. Turn Fuel Valve on. Inadequate engine oil. Check oil level. This engine is equipped with a low oil sensor. The engine cannot be started unless the oil level is above the prescribed lower limit. No spark at spark plug. Remove the spark plug cap. Clean any dirt
Resumen del contenido incluido en la página 20
SERVICE MAINTENANCE Keep all air vents clear. Keep the generator clean. DO NOT spray with water. Periodically check all fasteners and tighten, see the periodic maintenance chart. GFCI TEST RECORDS: As with any other safety devices, the GFCIs supplied with these generators must be checked every month to insure that they are functioning properly. To test the GFCIs, follow the instructions and then enter the date of the test below. 1. With the generator running and the idle control switch in the