IMPORTANT SAFETY INFORMATION READ ALL INSTALLATION INSTRUCTIONS Jacuzzi Whirlpool Bath does not recommend prolonged periods of use of the steamer. Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body’s ability to regulate its internal temperature (hyperthermia). Consult your physician about your safety and comfort before using the steam system. Limit your use of steam to 10–15 minutes until you’re certain of your body’s reaction. A cooli
Resumen del contenido incluido en la página 3
Contents Installation of Steam Generator Specifications ______________________________________________________________________________ 1 How to Select Generator Size and Electrical Requirements ___________________________________________ 2 Locating the Steam Generator _________________________________________________________________ 3 Room Construction and Ventilation _____________________________________________________________ 3 Plumbing Instructions and Cautionary Notes on Installation ______
Resumen del contenido incluido en la página 4
INSTALLATION Specifications and Sizing of the Steam Generator for the Room Single-Phase Electrical Service Generator Power Size of Enclosure Required Rating at Voltage (cubic feet) 20 40 VAC 30 AMP 3 WIRE (#10)50 .0 kW@24 60-11 STEAMPRO 25 40/ S064000 28 08 VAC 30 AMP 3 WIRE (#10)30 .75 kW@20 60-8 20 40 VAC 40 AMP 3 WIRE (#8)70 .0 kW@24 110-22 STEAMPRO 240/7 S062000 28 08 VAC 40 AMP 3 WIRE (#8)50 .25 kW@20 80-15 20 40 VAC 60 AMP 3 WIRE (#6)10 0.0 kW@24 220-40 STEAMPRO 240/10 S060000 28 08 VAC 60
Resumen del contenido incluido en la página 5
INSTALLATION Locating the Steam Generator The steam generator must be installed upright and level. The steam generator must be located within a 25 foot maximum steam line run to the steam head AND within the 25 foot control wire length to any controls. It may stand attached to a horizontal base or to a wall. For wall mounting, use “keyhole” slots on a cabinet back to slip over screw heads and install a wood cleat or shelf to the wall at the bottom of the unit to help support the bottom. Add a cl
Resumen del contenido incluido en la página 6
INSTALLATION Plumbing Instructions and Cautionary Notes on Installation Minerals in the water or poor water quality can shorten the life of the steam generator or cause erratic operation if the tank is not drained regularly. Drain the tank frequently. Jacuzzi Whirlpool Bath also strongly recommends purchasing and installing the optional drain down valve. See the important note below. The tank will be drained automatically after each use after the water temperature lowers. Water filters and other
Resumen del contenido incluido en la página 7
INSTALLATION Plumbing Diagram STEAM UNIT TO BE LEVEL AND UPRIGHT SEE PAGE 5 FOR SUGGESTED LOCATIONS SEE CHART ON PAGE 4 FOR WATER SUPPLY REQUIRED WITH SHUT-OFF WIRE SIZE. VALVE (3/8 OR 1/2 INCH COPPER) TO STEAM HEAD SEE PAGES 8 AND 9 FOR STEAM HEAD PLUMBING AND INSTALLATION FOR VARI- OUS WALL SURFACES. STEAM PIPE 1/2 INCH (MINIMUM SIZE) COPPER. 25 FOOT TOTAL MAXIMUM RUN. DO NOT PLACE ANY VALVES OR DIPS IN THIS LINE. PIPE INSULATION RECOMMENDED PRESSURE RELIEF VALVE 3/4 NPT (PROVIDED WITH STEAM G
Resumen del contenido incluido en la página 8
INSTALLATION Steam Head Installation for Various Wall Surfaces Jacuzzi Whirlpool Bath recommends that the steam shield be used for all steam head installations. The steam shield must be installed if the steam head is located on acrylic (or other plastic) wall surfaces or above a bath rim. The steam head is to be installed at 18 inches minimum height above the floor or shower base. The steam head is to be installed at 10 inches minimum above a bath rim. Caution: Consult the manufacturer of the en
Resumen del contenido incluido en la página 9
INSTALLATION 10 kW Steam Generator with Two Steam Heads Two steam heads may be installed with the Model E210000 Steam Generator, if desired. This will reduce the sound level of the exiting steam and will provide more even steam distribution and less heat concentration in larger steam enclosures. 3' MINIMUM POSITIONING TWO STEAM HEADS WITH MODEL E210000 STEAM GENERATION (10 kW) 7
Resumen del contenido incluido en la página 10
INSTALLATION Automatic Drain Valve Installation (Optional) Important Note About Tank Drain Selection: Jacuzzi Whirlpool Bath strongly recommends purchasing and installing the optional Automatic Drain Valve for the steam generator. This valve prevents standing water from remaining in the tank between uses. This valve must be installed where the steam generator may be exposed to freezing temperatures, e.g., in seasonal- use homes. This valve automatically drains the tank when the water has cooled
Resumen del contenido incluido en la página 11
INSTALLATION Steam Controls—Available Installation Methods Various control packages are available for use with the steam generator. The following instructions (A–C, pages 12 - 16) describe the different installations. Select one of the following control options: A. ON/OFF 30 minute control. B. 30 minute temperature control. C. Digital time and temperature control. S083827 S061827 S06 3827 S0618 29 S083827 S068829 (no sensor, no cable ( with sensor and cable) (with sensor and cable 9
Resumen del contenido incluido en la página 12
INSTALLATION A. STEAM CONTROL BY 30 MINUTE LOW VOLTAGE ON/OFF CONTROL. 1. Control cable rough-in: The low voltage control can be mounted up to 75 feet THIS LOW VOLTAGE CONTROL CAN from the generator either inside or outside the steam BE LOCATED INSIDE OR OUTSIDE room. (A 25’ cable provided.) Also, see # 4 Optional THE STEAM ENCLOSURE Secondary Generator Control. String (3) 18 to 22 AWG solid wires from the control location through 1/2" holes in the wall studes or ceiling joists to the generator.
Resumen del contenido incluido en la página 13
INSTALLATION GENERAL INSTRUCTIONS FOR TEMPERATURE CONTROL MODELS 1. Control Cable Rough-in The low voltage control can be mounted up to 25 feet from the generator either inside or outside the steam room, also see #6 optional secondary digital generator control. String the 25' cable from the 6" MIN - TEMPERATURE SENSOR control location through 1/2" holes in the wall studs or ceiling joists to the generator. Note: Do not staple STEAM CONTROL through or damage cable. Use factory supplied cables onl
Resumen del contenido incluido en la página 14
INSTALLATION 5. INSTALL GENERATOR CONTROL The low voltage control can be mounted directly to a finished wall either inside or outside the steam room. TEMPERATURE SENSOR PLUG (J4) Using a 2" hole saw, drill a hole in the finished wall where the control is to be mounted (the control cable should OPTIONAL AUTOMATIC DRAIN CONNECTION already be roughed-in to this location). Locate the control cable, pull it out through the 2" hole and plug it into the SK1 SK3 connector on the back of the control hous
Resumen del contenido incluido en la página 15
OPERATION B. 30 MINUTE TEMPERATURE CONTROL The 30 minute temperature control features a 30 minute press on timer lighting up the word "STEAM" and a thermostatic control preset to reach 120 degrees Fahrenheit. The digital control can be mounted either inside or outside the steam room. The preset temperature can be adjusted in a range between 100 degrees and 125 degrees Fahrenheit. Once the set temperature is reached the ''soft steam'' feature automatically engages cutting steam production back to
Resumen del contenido incluido en la página 16
OPERATION C. DIGITAL TIME AND TEMPERATURE CONTROL The digital control features an adjustable 60 minute time and temperature control with digital display. The actual room temperature and time remaining are alternately displayed every 5 seconds. The primary control can be mounted either inside or outside the steam room and an optional secondary control is available to mount in an alternate location. The temperature can be adjusted in a range between 100 degrees and 125 degrees Fahrenheit wit
Resumen del contenido incluido en la página 17
SERVICE Description of SteamPro Steam Generator The SteamPro series generator is the latest in modern steam generator design. The SteamPro steam generator uses a printed circuit assembly to monitor and control all the equipment needed to produce steam. The system has three functions: a timer that controls the length of the steam bath; the operating water level is monitored and controlled; and the heating elements are protected by a minimum water level sensor. The generator is compartmentalized i
Resumen del contenido incluido en la página 18
TROUBLESHOOTING There are no user serviceable parts in the Generator. All repair should be performed by a qualified service person. For additional assistance or the factory authorized service person nearest you call the Service Department at 1-800- 363-0251. The Trouble Shooting Guide below is meant as a general aid only. Follow ACTION TO BE TAKEN in order until the problem is resolved. Where replacements or repairs are indicated, see the appropriate paragraph of SERVICE SECTION. SS YMPTOMSPN RO
Resumen del contenido incluido en la página 19
TROUBLESHOOTING SS YMPTOMSPN ROBABLE CAUSE ACTION TO BE TAKE Control "ON". Unit has not filled completely. 1. a. Push the control "OFF". (Control light on) Heating elements burnt out. b. Open the drain valve allowing tank to drain completely. Unit won't steam. Level probe faulty. c. Close the drain valve. "PCA" printed circuit assembly is d. Push the control "ON". Note: Steam lit faulty. e. Unit will begin filling, listen for a click noise. Within 20 seconds after steadily or click noise is hear
Resumen del contenido incluido en la página 20
WIRING DIAGRAM ON/OFF 12 3 JP2 J5 TB1 R OPTIONAL AUTOMATIC DRAIN H J1 L W1 K3 K4 W2 TB2 (30 MIN) JP1 SK1 WATER VALVE (DIGITAL) SK3 K1 K2 (DIGITAL) L1 L2 SK4 100mA SLO-BLOW 1A FAST-BLOW J4 F1 F2 WHITE WHITE STEAM GENERATOR BLUE TEMPERATURE SENSOR (STEAM ROOM) RED ORANGE WIRES WIRES 30 MINUTE TEMP OR DIGITAL CONTROL OPTIONAL SECOND DIGITAL ELEMENT ELEMENT CONTROL TANK - SIDE TANK - FRONT PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. USE INSTALLATION INSTRUCTIONS SUPPLIED WITH PROD