Thank you for purchasing a Honda generator. We want to help you get the best results from your new generator and to operate it safely. This manual contains the information on how to do that; please read it carefully. This owner’s manual describes the operation and maintenance of the EX650 Honda Generator. All information in this publication is based on the latest product information available at the time of printing. Honda Motor Co., Ltd. reserves the right to make changes at any time with
Resumen del contenido incluido en la página 4
CONTENTS SAFETY .4 ..................................................................................................... .4 Safety Label Locations .......................................................................... .................................................................................. 6 Safety Information COMPONENT IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 10 ........
Resumen del contenido incluido en la página 5
.24 MAINTENANCE ....................................................................................... 24 ......................................................................... Maintenance Schedule .25 Tool Kit ................................................................................................ Engine Oil Change .............................................................................. .26 .27 Air Cleaner Service ......................................................
Resumen del contenido incluido en la página 6
SAFETY SAFETY LABEL LOCATION These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact your Honda Generator dealer for a replacement. E BEFORE FllllNC FUEL TANK. W NOT FILL OVER ICONTR~LER QU’IL N’Y ANI FIJITE NESSENCE REPANDUE SUR L’APPAREIL AVANT DE REFAIRE LE PLEIN: ARRiTER LE MOTEUR NE PAS FAIRE LE PLEIN AU DESSUS DU REPERE DE NlVF.AU MAXIMUM. ll1D” FI\“DIIPIID,L ncnnA”“nn n CPPRDC INTES EC
Resumen del contenido incluido en la página 7
HONDA EXIOOO HONDA MOTOR CO., LTD. MADE IN JAPAN&I CONTAINS POISONOUS CAREON MONOXIDE. lLUBRlCANT : 0.431 HOUSE WIRING. THIS CAN DAMAGE THE GENERATOR OR ELECTORICAL APPLIANCES. lCLEAN ELEMENT EVERY 50 HOURS (EVERY 10 HOURS UNDER DUSTY CONDITIONS) WASH IN HIGH FLASH-POINT SOLVENT, SQUEEZE DRY, THEN DIP IN CLEAN ENGINE OIL AND 5
Resumen del contenido incluido en la página 8
SAFETY INFORMATION Honda generators are designed to give safe and dependable service if operated according to instructions. Read and understand this owner’s manual before operating your generator. You can help prevent accidents by being familiar with your generator’s controls, and by observing safe operating procedures Operator Responsibility 0 Know how to stop the generator quickly in case of emergency. l Understand the use of all generator controls, output receptacles, and connections
Resumen del contenido incluido en la página 9
Fire and Burn Hazards l The exhaust system gets hot enough to ignite some materials. - Keep the generator at least 1 meter (3 feet) away from buildings and other equipment during operation. - Do not enclose the generator in any structure. - Keep flammable materials away from the generator. l The muffler becomes very hot during operation and remains hot for a while after stopping the engine. Be careful not to touch the muffler while it is hot. Let the engine cool before storing the gener
Resumen del contenido incluido en la página 10
COMPONENT ODENTUFICATION FRAME SERIAL NUMBER CIRCUITBREAKERS I TOP COVER TOOL KIT I SPARK PLUG CAP I I PILOT LAMP J / ENGINE FREQUENCY SWITCH w METER LEFT SIDE COVER AC RECEPTACLES GROUND TERMINAL ENGINE SERIAL NUMBER I I RECOIL OIL FILLER CAP STARTER GRIP l Record the engine and frame serial numbers for your future reference. Refer to these serial numbers when ordering parts, and when making technical or warranty inquiries (see page 39) Frame serial number: Engine
Resumen del contenido incluido en la página 11
CARRYING HANDLE FUEL GAUGE FUEL TANK CAP \ I RIGHT SIDE, COVER CHOKE LEVER AIR CLEANER EXHdUST OUTLET CASE MUFFLER COVER 9
Resumen del contenido incluido en la página 12
CONTROLS Engine Switch To start and stop the engine. Switch position: OFF: To stop the engine. ON: To run the engine. 0 -3 ENGINE SWITCH Recoil Starter To start the engine, pull the starter grip lightly until resistance is felt, then pull briskly. (1 Do not allow the starter to snap back against the engine. Return it gently to prevent damage to the starter. PILOT LAMP 10
Resumen del contenido incluido en la página 13
Choke Lever The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed by operating the choke lever manually. Move the lever to the CLOSED position to enrich the mixture. ‘CLOSED Pilot Lamp The pilot lamp is illuminated when the generator is operating normally. It indicateds that the generator is producing electrical power. If the pilot light is illuminated, the frequency meter should be displaying 60Hz. , 1’ I\ 11
Resumen del contenido incluido en la página 14
Ground Terminal I The gernerator ground terminal is connected to the frame of the generater, the metal non-current carrying parts of the generator, and the ground terminals of each receptacle. Before using the ground terminal, consult a qualified electrician, electrical inspector or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator, 12
Resumen del contenido incluido en la página 15
Oil Alert System The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert system will automatically stop the engine (the engine switch will remain the ON position). If the engine stops and will not restart, check the engine oil level (p.20) before trouble shooting in other areas. DIPSTICK AC Circuit Breaker The AC circuit Breaker automatically shuts
Resumen del contenido incluido en la página 16
DC Terminals The DC terminals may ONLY be used for charging 12 volt automotive type batteries. The terminals are colored red to identify the positive (+) terminal and black to identify the negative (-) terminal. The battery must be connected to the generator DC terminals with the proper polarity (battery positive to generator red terminal and battery negative to the generator black terminal.) NEGATIVE DC TERMINAL (BLACK) DC Circuit Breaker The DC circuit breaker automatically shuts o
Resumen del contenido incluido en la página 17
GENERATOR USE Connections to a Building’s Electrical System Connections for standby power to a building’s electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes. m Improper connections to a building’s electrical system can allow electrical current from the generator to backfeed into the utility lines. Such backfeed may electrocute utility company workers o
Resumen del contenido incluido en la página 18
AC Operation 1. Start the engine (refer to page 24) and make sure the pilot lamp comes on. If not, the filament may be burnt out. 2. Plug in the appliance. CAUTION: Substantial overloading will switch off the circuit breaker. Marginal overloading may not switch off the circuit breaker, but it will shorten the service life off the generator. Be sure that all appliances are in good working order before connecting them to the generator. If an appliance begins to operate abnormally, becomes
Resumen del contenido incluido en la página 19
DC Operation The DC terminals may ONLY be used for charging 12 volt automotive-type batteries. Connecting the battery cables: 1. Before connecting charging cables to a battery that is installed in a vehicle, disconnect the vehicle’s ground cable from the battery. m The battery gives off explosive gases; keep sparks, flames and cigarettes away. Provide adequate ventilation when charging or using batteries. 2. Connect the positive (+) battery cable to the battery positive (+) terminal. 3
Resumen del contenido incluido en la página 20
Disconnecting the battery cables: 1. Stop the engine, 2. Disconnect the negative (-) battery cable from the generator negative (-) terminal. 3. Disconnect the other end of the negative (-) battery cable from the battery negative (-) terminal. 4. Disconnect the positive (+) battery cable from the generator positive (+) terminal. 5. Disconnect the other end of the positive (+) battery cable to the battery positive(+) terminal. 6. Connect the vehicle ground cable to the battery negative (