Resumen del contenido incluido en la página 1
Yeoman CL
Free Standing Stove
Models: YM-CL3MF / YM-CL5W / YM-CL5MF / YM-CL8W / YM-CL8MF
This design is protected under Registered Community Design no's. 001202600-0004 / 001202600-0005 / 001202600-0006
Instructions for Use,
Installation and Servicing
For use in GB & IE (Great Britain and Republic of Ireland).
This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated
instructions and in
Resumen del contenido incluido en la página 2
COVERING THE FOLLOWING MODELS: MODELS: YM-CL3MF / YM-CL5W / YM-CL5MF / YM-CL8W / YM-CL8MF APPLIANCE COMMISSIONING CHECKLIST 3 COMMISSIONING 24 USER INSTRUCTIONS 4 MAINTENANCE & SERVICING 25 General Points 4 Annual Service 25 Using the Appliance for the first time 5 Removal of Log Guard 26 Recommended Fuels 5 Removal of Firebricks 26 Lighting the Appliance 6 Removal of Baffle 26 Running the Appliance 7 Fitting a New Glass Door 26 Burning Tips 8 Fitting a New Door Seal 27 Ash Removal 9 A
Resumen del contenido incluido en la página 3
APPLIANCE COMMISSIONING CHECKLIST To assist us in any guarantee claim please complete the following information:- Retailer appliance was purchased from Name: ................................................................................................................................................................. Address: ............................................................................................................................................................... ..........
Resumen del contenido incluido en la página 4
USER INSTRUCTIONS 1. GENERAL POINTS 1.1 Before use of this appliance please read these instructions fully. * The appliance must be fitted by a registered installer , or approved by your local building control officer. Data Plate 1.2 All local regulations, including those referring to national and European Standards need to be complied with when installing the appliance. 1.3 Only use for domestic heating in accordance with these PR8745 operating instructions. The data plate is found o
Resumen del contenido incluido en la página 5
USER INSTRUCTIONS —All open flued appliances can be affected by temporary Airwash Control atmospheric conditions which may allow fumes to CLOSE OPEN enter the house. Because of this an electronic carbon monoxide detector conforming to the latest edition of BSEN50291 must be fitted in the same room as the appliance. The existence of an alarm must not be considered a substitute for ensuring regular servicing and maintenance of the appliance and chimne
Resumen del contenido incluido en la página 6
USER INSTRUCTIONS Do not burn construction timber, painted, impregnated —Place firelighters or paper and dry kindling wood on the / treated wood, manufactured board products or pallet grate. wood. —Light the paper or firelighters (see Diagram 5). 3.2 Solid fuel Burn only anthracite or manufactured briquette smokeless fuels listed as suitable for use with closed heating appliances. Do not burn bituminous coal, ‘petro-coke’ or other petroleum based fuels as this will invalidate the
Resumen del contenido incluido en la página 7
USER INSTRUCTIONS 5.6 Burning Solid Fuel Mutli-fuel Stove Air Inlets Solid Fuel can only be burned in a multi-fuel stove. Only for use with recommended fuels (see User Instructions, Section 3). Set air controls (see Diagram 9). Airwash: 50% Log Guard PR8742 —Close the door. 5. RUNNING THE APPLIANCE 5.1 Burning Wood —Close the Primary Air control and use the Airwash to control the temperature (see Diagram 8). Airwash: Adjust Primary Air: 50% PR8727 5.7 De-ash the fire bed befor
Resumen del contenido incluido en la página 8
USER INSTRUCTIONS 5.12 Do not burn bituminous coal, ‘petro-coke’ or other Draught is caused by the rising hot air in the chimney when petroleum based fuels, as this invalidates the product the appliance is lit. guarantee. Symptoms of poor performance related to flue draught Do not load fuel above the log guard and the secondary include: combustion inlets at the back of the firebox —Excessive fuel consumption (high flue draught). (see Diagram 6). —Poor burning control, overheating (high fl
Resumen del contenido incluido en la página 9
USER INSTRUCTIONS —Use smokeless fuel or small, thick logs. 7. ASH REMOVAL 9. OVER-FIRING 7.1 Multi-fuel stove 9.1 Do not over-fill with fuel or run at high temperatures for Riddle with the tool provided (see Diagram 9). long periods or over-firing can occur. If the flue pipe, flue collar or top plate glow red the appliance is over-firing. Close the air controls to reduce the temperature. 9.2 Over-firing can cause permanent damage to the appliance. 10. CHIMNEY FIRE 10.1 If a chimney fire
Resumen del contenido incluido en la página 10
USER INSTRUCTIONS Check for obvious build up of soot, ash or debris above the 13.2 The chimney, any connecting flue pipe and the appliance flue baffle(s) (these can be found in the upper part of the flue ways, if incorporated, must be regularly cleaned. firebox). Use a torch if necessary. 13.3 Ensure adequate access for cleaning where it is not possible If there are any signs of a build up of debris above the flue to sweep through the chimney. baffle(s) either: 13.4 If the chimney is belie
Resumen del contenido incluido en la página 11
USER INSTRUCTIONS This is caused by burning damp wood and running the 16. TROUBLESHOOTING TIPS appliance at too low a temperature. Use well seasoned wood and operate the appliance within 16.1 Stove glass blackening the ideal temperature range. This has four possible causes: Tar is a major cause of chimney fires. If the appliance 1. Incorrect use of Airwash experiences problems with tar build up consult a chimney See User Instructions, Sections 1, 4 and 5 for the correct use sweep befor
Resumen del contenido incluido en la página 12
TECHNICAL SPECIFICATION YEOMAN Model Yeoman CL3 - YM-CL3MF Yeoman CL5 - YM-CL5W / YM-CL5MF Yeoman CL8 - YM-CL8W / YM-CL8MF Wood kW 3.75 4.9 8 Nominal Heat Output Solid Fuel kW 3.75 4.9 8.6 mm Wg 1.25 1.25 1.25 Flue Draft at Nominal Heat Output All Fuels inch Wg 0.05 0.05 0.05 Wood g/s 3.8 2.6 7.0 Flue Gas Mass Flow Solid Fuel g/s 2.9 3.2 7.3 Wood °C 408 369 446 Flue Gas Temperature at Spigot/Socket Solid Fuel °C 408 369 446 mm 125 125 150 Flue Outlet Size (Top or Rear Option) inch 5 5 6 Minimum
Resumen del contenido incluido en la página 13
TECHNICAL SPECIFICATION YEOMAN DIMENSIONS C A D F K E B G J PR8642 Cast Top Plate H PR8753 incl. feet @ 6mm on underside Description Model A B C D E F (Ø) G H J K Yeoman CL3 YM-CL3MF 360 510 306 93 416 128/5" 400 22 240 195 YM-CL5W 408 Yeoman CL5 435 518 303 90 424 128/5" 24 315 199 YM-CL5MF YM-CL8W Yeoman CL8 563 572 363 105 478 153/6" 449 24 441 225 YM-CL8MF All dimensions are in mm (25.4mm = 1") 13
Resumen del contenido incluido en la página 14
SITE REQUIREMENTS 1.4 Suitable access must be provided to enable the collection 1. FLUE OR CHIMNEY and removal of debris. 1.5 The flue must be swept and inspected when the appliance 1.1 The flue or chimney system must be in good condition. is installed. It must be inspected by a competent person and passed for use with the appliance before installation. 1.6 The flue draught must be checked with all windows and doors closed and any extraction fans in this, or adjoining Products of combusti
Resumen del contenido incluido en la página 15
SITE REQUIREMENTS 1. FLUE OUTLET POSITIONS Horizontal Terminal Measurement Flue 150mm Vertical max Measurement Adjacent Building Insulation The vertical measurement is the lowest from either the point of discharge or 150mm above insulation. IMPORTANT: Seek specialist advice if installing in a dwelling with a thatched roof Position On Roof Minimum Clearances On ridge or within 600mm 600mm above ridge A Elsewhere on roof 2300mm horizontally from roof surface and: B a) 1000mm above highest p
Resumen del contenido incluido en la página 16
SITE REQUIREMENTS WALLS NExT TO A HEARTH Solid, non-combustible Thickness W material e.g. masonry or concrete H 150mm minimum C 150mm C minimum PR8731 Position of Appliance & Hearth in relation to walls Requirement for the walls Distance of hearth from wall Distance of Appliance to wall Min thickness of Wall Min height of wall 'C' 'W' 'H' 0mm 0mm - 50mm 200mm Height of appliance + 300mm Or 1200mm from the hearth (take largest dimension) 0mm 51mm - 300mm 75mm 0 - 150mm 150mm + 75mm 1200mm 150
Resumen del contenido incluido en la página 17
PRE-INSTALLATION CHECKS 1. FLUE Model Yeoman CL3 - YM-CL3MF Yeoman CL5 - YM-CL5W / YM-CL5MF Yeoman CL8 - YM-CL8W / YM-CL8MF mm 150 150 150 Without Liner System Round (diameter) inch 6 6 6 mm 135 135 135 Without Liner System (square) Flue / Chimney Size Minimum Dimension inch 5½ 5½ 5½ mm ‡150 150 150 With Liner or Factory Made System (diameter) mm ‡6 6 6 m 4 4 4 Flue / Chimney minimum height* feet 13 13 13 *When measured from the top of the flue, with no horizontal sections and a maximum of 4 b
Resumen del contenido incluido en la página 18
PRE-INSTALLATION CHECKS 2.7 Ventilation requirements in the UK are as shown in the table 2.10 Site the vents where cold draught is unlikely to cause below: discomfort. This can be avoided by placing vents near ceilings or close to the appliance, see diagram below. A) Traditionally Built Homes 3 2 — Where the leakage is greater than 5m /hour/m . 2 — Ventilation normally required = 550mm per kW output over 5kW Output (kw) 4 5 6 7 8 9 10 2 mm None None 550 1100 1650 2200 2750 Additional 2
Resumen del contenido incluido en la página 19
INSTALLATION INSTRUCTIONS 1.1 Take care when installing the appliance. Careless LEGAL REQUIREMENTS handling and use of tools can damage the finish and/or area. Before installation and/or use of this appliance please read these instructions carefully to ensure that all Choose top or rear flue exit (see Diagram 1). requirements are fully understood. Hexagonal Nuts The appliance must be fitted by a registered installer*, Hexagonal Bolts & Washers or approved by your local building contro
Resumen del contenido incluido en la página 20
INSTALLATION INSTRUCTIONS —Secure with self tapping screw. —Seal the connecting joints. Do not use a 90˚elbow to make this connection. The flue must be installed in accordance with manufacturers instructions. Seal Collar with Fire Cement Self tapping screw PR8009 Tee The flue must be installed in accordance with manufacturers instructions. Size Stovax Part No. ‡ 5" 4516 Flue Pipe 915mm (3ft) 6" 4616 Size Stovax Part No. ‡ 5" 4502 6" 4602 Cap PR8735 Self tapping screw at rear To chimney