Resumen del contenido incluido en la página 1
R
Cape Cod Woodstove
Beaverton
Tested and
O-T L
Oregon USA
Listed by
C
CAUTION!
OMNI-Test Laboratories, Inc.
The baffle and kaowool blanket placement
is crucial to the optimum performance
of the stove. Follow the steps on pg. 33
carefully to ensure proper placement
of baffles and kaowool at time of initial
installation and following chimney clean-
ing.
This manual contains instructions for Installation, Operation & Maintenance
Please read this entire manual before you install and use your
Resumen del contenido incluido en la página 2
R Cape Cod Wood Stove NOTES My new Cape Cod wood stove.... SERIAL NUMBER: DATE PURCHASED: DEALERSHIP: DEALER PHONE #: ADDITIONAL INFORMATION PERTINENT TO YOUR INSTALLATION: ATTACH SALES RECEIPT & WARRANTY STUB HERE: This information will be necessary should your stove require Warranty service. 32198A February 15, 2002 32198A February 15, 2002 Page 2
Resumen del contenido incluido en la página 3
R Cape Cod Wood Stove WELCOME Aladdin Hearth Products welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation of ou
Resumen del contenido incluido en la página 4
R Cape Cod Wood Stove TABLE OF CONTENTS LISTINGS............................................................5 OPERATION SERIAL LABEL & LOCATON..........................6 PRE-USE CHECK.........................................26 DIMENSIONS.....................................................7 BURNING PROCESS ...................................26 CLEARANCES WOOD SELECTION AND STORAGE........27 TOP VENT INSTALLATIONS .....................8 AIR CONTROLS..................
Resumen del contenido incluido en la página 5
R Cape Cod Wood Stove LISTINGS LISTINGS & CODE APROVALS These installation instructions describe the cannot be unexpectedly cancelled. If any assistance installation and operation of the Cape Cod woodstove. is required during installation, please contact your This stove meets the U.S. Environmental Protection local dealer. Agency’s 1990 particulate emission standards. Inspect and clean vent system frequently in The Cape Cod is listed by OMNI-Test Laborato- accordance with the instructi
Resumen del contenido incluido en la página 6
R Cape Cod Wood Stove LABEL LOCATION: SAFETY LABEL BACK OF STOVE 32198A February 15, 2002 32198A February 15, 2002 Page 6 HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. CAUTION: KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS LISTED ROOM HEATER, SOLID FUEL TYPE. Tested and Beaverton Report #061-S-15-2 O-T L SERIAL NO. Listed by Oregon USA ALSO FOR USE IN MOBILE HOMES.
Resumen del contenido incluido en la página 7
R Cape Cod Wood Stove DIMENSIONS FRONT VIEW accessory parts 27" 26-1/2 29" SIDE VIEW 8-1/4" 22-1/2" 27-1/2" 16-1/4" 29-3/4" 16" 24-1/4" 32198A February 15, 2002 32198A February 15, 2002 Page 7
Resumen del contenido incluido en la página 8
R Cape Cod Wood Stove TOP VENT INSTALLATIONS CLEARANCES MINIMUM CLEARANCES TO COMBUSTIBLES (In inches and millimeters.) FIGURES 1, 2 & 3 SINGLE WALL: Six inch (6") diameter single wall, minimum 24 MSG black or blued steel connector pipe, with a listed factory-built chimney suitable for use with solid fuels, or a masonry chimney, and the following clearances: A B C D E F
Resumen del contenido incluido en la página 9
R Cape Cod Wood Stove REAR VENT INSTALLATIONS CLEARANCES MINIMUM CLEARANCES TO COMBUSTIBLES (In inches and millimeters) FIGURE 4 In a Masonry Fireplace OR Through the Wall: Six inch (6") diameter listed double wall air insulated connector pipe with listed factory-built Class “A” chimney or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Additional specifications include a maximum 8" deep mantel without heat shield and the following clearances:
Resumen del contenido incluido en la página 10
R Cape Cod Wood Stove FLOOR PROTECTION CLEARANCES The floor must be non-combustible or otherwise adequately protected from radiant heat given off by NOTE: Additional floor protection is required on the unit and from sparks and falling embers. A layer rear vent installations. For this type of installation the of thin brick or ceramic tile over a combustible floor floor protector must extend the length of the flue and 2" is not sufficient. to each side of the flue. Floor protection can
Resumen del contenido incluido en la página 11
R Cape Cod Wood Stove ACCESSORIES The Cape Cod has several options available for installation and appearance. These options are packaged and sold separately and are listed below. It is a good idea to plan your installation on paper, using exact measurements for clearances and floor protection, before actually beginning the installation. If you’re not using an existing chimney, place the stove where there will be a clear passage for a factory-built listed chimney through the ceiling and roof
Resumen del contenido incluido en la página 12
R Cape Cod Wood Stove CHIMNEY HEIGHT REQUIREMENTS INSTALLATION A masonry chimney or a factory-built chimney must be the required height above the roof and any other nearby obstructions. The chimney must be at least three feet FIGURE 6 higher than the highest point where it passes through the 2-10-3 RULE roof and at least two feet higher than the highest part of the roof or structure that is within ten feet of the 2 ft Min (61cm) chimney, measured horizontally. See Figure 6. These 3 ft
Resumen del contenido incluido en la página 13
R Cape Cod Wood Stove FLUE & VENTING SYSTEMS INSTALLATION WARNING: ALWAYS FOLLOW CHIMNEY CONNECTOR MANUFACTURER’S INSTRUCTIONS FOR PROPER INSTALLATION. CHIMNEY CONNECTOR IS TO BE USED ONLY WITHIN THE ROOM, BETWEEN THE STOVE AND CEILING WALL, NEVER PASSING THROUGH A COMBUSTIBLE CEILING OR WALL. THE CONNECTOR SHALL NOT PASS THROUGH AN ATTIC OR ROOF SPACE, CLOSET OR SIMILAR CONCEALED SPACE, OR A FLOOR, OR CEILING. MAINTAIN MINIMUM CLEARANCES TO COMBUSTIBLES AS REFERENCED ON PAGES 9, 10 & 1
Resumen del contenido incluido en la página 14
R Cape Cod Wood Stove MASONRY CHIMNEY INSTALLATION For optimal performance, masonry chimneys used to vent this appliance should be lined with Wood Stud 2" (51mm) a 6" stainless steel liner. Installations into a clay Clearance from Fireclay liner 5/8" chimney wall flue without a stainless steel liner may reduce (16mm) Minimum or efficiency, cause the glass to darken, and produce Equivalent. excessive creosote. Ensure that a masonry chimney meets the Header minimum standards of the Nat
Resumen del contenido incluido en la página 15
R Cape Cod Wood Stove EIGHT INCH SOLID PACK CHIMNEY INSTALLATION WITH METAL SUPPORTS AS A THIMBLE FIRECLAY FLUE LINER WITH AIR SPACE CONCRETE CAP RAFTER FLASHING 1" CLEARANCE WITH FIRESTOP CEILING JOIST EAVE COMBUSTIBLE WALL 1" CLEARANCE THIMBLE, 12" OF BRICK SHEATHING FLOOR PROTECTOR AIRTIGHT CLEANOUT DOOR FIGURE 8 FIGURE 9 32198A February 15, 2002 32198A February 15, 2002 Page 15
Resumen del contenido incluido en la página 16
R Cape Cod Wood Stove MASONRY CHIMNEY INSTALLATION First, make the frame for the thimble, ensuring For the method of installation to a masonry it is no smaller than 14" square, to maintain a 2" air chimney shown in Figures 10 & 11, (on page 17), space around the chimney section. Attach the wall it will be necessary to purchase an 8 inch inside spacer to the chimney side of the frame. Then insert diameter, 12 inch long section of prefabricated listed the frame into the opening, toe nail
Resumen del contenido incluido en la página 17
R Cape Cod Wood Stove MASONRY CHIMNEY, CONT. INSTALLATION Min. Chimney Clearance to Wall Spacer and Combustibles - 2" (51mm) Min. Clearance 2" (51mm) 1" (25mm) Air Space Chimney Flue Liner to Chimney Section Fireclay Liner or Equivalent Chimney Connector Chimney Section Trim Collar Wall Band Wall Spacer Masonry Chimney Constructed to NFPA 211 FIGURE 10 Fire Clay Flue Liner with Airspace Masonry Chimney Trim Collar Wall Spacer Chimney Section with 2" (51mm) Clearance to Combustibles W
Resumen del contenido incluido en la página 18
R Cape Cod Wood Stove CONNECTION TO A MASONRY INSTALLATION FIREPLACE There are several kits available to connect the stove to a masonry fireplace. Look for a listed kit. The kit is an adapter which is installed at the location of the fireplace damper. The existing damper may have to be removed to allow installation of the kit. The key points of this type of stove connection are that the connector pipe must extend up the chimney above where the fire clay liner starts, and the areas of the
Resumen del contenido incluido en la página 19
R Cape Cod Wood Stove CONNECTION TO A METAL INSTALLATION PREFABRICATED CHIMNEY The other method is to install an exterior chimney that runs up the outside of the residence. When a metal prefabricated chimney is used, See Figures 15 and 16. (The components illustrated the manufacturer’s installation instructions must be may not look exactly like the system you purchase, followed precisely. It will be necessary to install the but they demonstrate the basic components necessary ceiling
Resumen del contenido incluido en la página 20
R Cape Cod Wood Stove CONNECTION TO AN INTERIOR METAL PREFABRICATED CHIMNEY INSTALLATION FIGURE 13 Listed Chimney Attic Listed Cap Insulation Combustible Shield Maintain 2" (51mm) Storm Collar Ceiling Specified Joists Clearance Flashing Chimney Ceiling Connector Listed Chimney To Stove FIGURE 14 Ceiling Support Combustible Wall Chimney Connector * * Refer to Clearances to Combustibles * Floor Protector IMPORTANT ! FOLLOW THE MANUFACTURERS’ INSTALLATION INSTRUCTIONS AND M