Resumen del contenido incluido en la página 1
Models:
Installers Guide
FB-Grand
FB-IN
CFX-Grand-B
CFX-IN-B
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
WARNING: IF THE INFORMATION
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
WARNING: IMPROPER INSTALLA-
EXPLOSION MAY RESULT CAUS-
TION, ADJUSTMENT, ALTERATION,
ING PROPERTY DAMAGE, PER-
SERVICE OR MAINTENANCE CAN
SONAL INJURY, OR DEATH.
CAUSE INJURY OR PROPERT
Resumen del contenido incluido en la página 2
SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully described in the Installing the Fireplace section of ! ! before starting the installation. FAILURE TO the Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result components MAY BE USED. in a possible fire hazard and will void the warranty. This gas fireplace and vent assembly MUST be Prior to the first firing of the fireplace, READ the !
Resumen del contenido incluido en la página 3
TABLE OF CONTENTS Safety and Warning Information ............................................... 2 u Service Parts Lists .................................................................... 4 Section 1: Approvals and Codes ............................................ 10 Appliance Certification ............................................................... 10 Installation Codes ...................................................................... 10 u High Altitude Installations ...............
Resumen del contenido incluido en la página 4
FB-GRAND, CFX-GRAND-B Service Parts CFX-Grand-B: Manufacturing Dates: 9-01 to 12-02 (NG, LP) Exploded Parts Diagram FB-Grand-B: Manufacturing Dates: 8-02 to _____ (GN, PL) Vue éclatée des pièces u 13 FB-GRAND SHOWN 12 20 19 21 1 3 2 16 22 17 9 10 18 15 11 14 4 Log Set Assembly 8 5 6 Part number list on following page. Part number list on following page. * * 7 La liste des numéros de pièce se trouve La liste des numéros de pièce se trouve * * à la page suivante. à la page suivante. 4
Resumen del contenido incluido en la página 5
(NG, LP) Service Parts List / Liste des pièces de rechange FB-GRAND IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de mo
Resumen del contenido incluido en la página 6
(NG, LP) Service Parts List / Liste des pièces de rechange CFX-GRAND-B IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de
Resumen del contenido incluido en la página 7
FB-IN, CFX-IN-B Service Parts (NG, LP) Exploded Parts Diagram CFX-IN-B: Manufacturing Dates: 12-02 to 9-01 (GN, PL) Vue éclatée des pièces FB-IN: Manufacturing Dates: 8-02 to ____ u 12 FB-IN SHOWN 20 19 21 22 2 3 1 16 17 9 18 10 15 11 4 Log Set Assembly 14 8 5 Part number list on following page. 7 * La liste des numéros de pièce se trouve * 6 à la page suivante. 7
Resumen del contenido incluido en la página 8
FB-IN Service Parts List / Liste des pièces de rechange IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour
Resumen del contenido incluido en la página 9
(NG, LP) Service Parts List / Liste des pièces de rechange CFX-IN-B IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de
Resumen del contenido incluido en la página 10
Approvals and Codes Appliance Certification room in the U.S.A. and Canada. u High Altitude Installations The Heat-N-Glo appliance models discussed in this Installers Guide have been tested to certification standards U.L. Listed gas appliances are tested and approved with- and listed by the applicable laboratories. out requiring changes for elevations from 0 to 2,000 feet in the U. S. A. and in Canada. Certification When installing this appliance at an elevation above 2,000 feet, it may be necess
Resumen del contenido incluido en la página 11
Getting Started Introducing the Heat-N-Glo Gas Appliances 3. To assure top performance, safety and efficiency, inserts must be installed with an approved flue liner as per CAN/ Heat-N-Glo direct vent gas appliances are designed to CGA B-149 or National Fuel Code ANSI Z223 and these operate with all combustion air siphoned from outside of instructions. the building and all exhaust gases expelled to the outside. WARNING: A HEARTH OR HEARTH EXTEN- The information contained in this Installers Guide,
Resumen del contenido incluido en la página 12
INLET AIR STARTING COLLAR EXHAUST STARTING SURROUND COLLAR ON/OFF DOOR SWITCH GLASS ASSEMBLY LOWER GRILLE RATING PLATE GAS CONTROL VALVE LOW VOLTAGE WIRES ELECTRICAL JUNCTION BOX ACCESS GAS ACCESS B TOP VIEW C 2” (50.8mm) A MINIMUM FIREPLACE SIZE CFX-GRAND-B and FB-GRAND CFX-IN-B and FB-IN Location Inches Millimeters Inches Millimeters A Front Width 35 889 30-1/4 768.4 B Rear Width 22-5/8 574.7 19 482.6 C Depth 14-1/8 358.8 14-1/8 358.8 * Height 25-3/4 654 22-1/2 571.5 * NOTE: If exha
Resumen del contenido incluido en la página 13
Dimensions in brackets are millimeters. A 5-9/16 [142] B 2-1/2 [64] REF 4 2-1/16 [102] [52] 13-3/4 [350] 3-1/8 [80] C ø 2-13/16 (2) D [71] F H E G 1-1/16 [28] GAS INLET ELECTRICAL 1-9/16 6-5/8 ACCESS 3-9/16 [40] [169] [91] (IF EQUIPPED) MODEL DIMENSIONS CFX-GRAND-B and FB-GRAND CFX-IN-B and FB-IN Location Inches Millimeters Inches Millimeters A 22-1/2 571 18 457 B 8-3/4 222 6-1/2 165 C 33-3/4 857.2 29-3/8 746.1 D 30-9/16 776 26-1/16 661 E 23-7/8 606 20-5/8 524 F 18-7/16 468 15-3/16 385 G 25-3/8
Resumen del contenido incluido en la página 14
Installing the Insert of the last section of vent pipe. See dimension V in Figure 4. Step 1. Installing the Vent System A vertical vent termination system installed on this model will include one (1) length of 3-inch flexible vent pipe for the Vent System Installation Precautions combustion air, one (1) length of 3-inch flexible vent pipe for Before starting installation of vent kits, the installer should the exhaust air, one (1) pipe-to-cap adaptor, and one (1) read these instructions and the
Resumen del contenido incluido en la página 15
Slide the gas insert into place, and HORIZONTAL OVERHANG position any excess flexible vent pipe back up into the chimney. Attach the pipe-to- cap adaptor to the termination cap and to the top of the flexible vent pipe and set VERTICAL WALL 2 FT. the cap in place at the top of the chimney. 2 FT. MIN. MIN. See Figures 4 and 5. LOWEST DISCHARGE CAUTION: TO AVOID DOWNDRAFTS OPENING AND/OR COLD AIR PROBLEMS, IT IS TERMINATION CAP RECOMMENDED TO SEAL OFF THE AREA BETWEEN THE TERMINATION CAP AND THE
Resumen del contenido incluido en la página 16
This option shows both exhaust and inlet air vent pipes attached to the adaptor. TERMINATION CAP ADAPTOR EXHAUST COLLAR INLET AIR COLLAR EXHAUST VENT PIPE V= 14 FT. MINIMUM 40FT. MAXIMUM 3 INCH COLLAR (Factory installed to stainless steel section) WARNING: DO NOT BLOCK PIPE END WITH INSULATION OR ANY OTHER SEALING MATERIAL STAINLESS STEEL PIPE - 3 FT. MIN. REQUIRED (INCLUDED) INLET AIR VENT PIPE COLLAR ATTACHMENT BRACKET Figure 4. WARNING: THE EXHAUST VENT PIPE MUST THE INLET AIR PIPE
Resumen del contenido incluido en la página 17
Note: Inspect for exhaust LOCKING collar gasket to insure TABS positive exhaust seal. LOCKING HANDLE TERMINATION CAP ADAPTOR EXHAUST VENT PIPE SUPPLIED WITH TERMINATION KIT INLET AIR VENT COLLAR (LINK-DV30 SHOWN) SLIDING PLATE INLET AIR VENT PIPE 3 INCH STAINLESS STEEL COLLAR ADAPTER FOR EXHAUST (MUST BE INSTALLED) Figure 5. Typical configuration of vent liners. 17
Resumen del contenido incluido en la página 18
Step 2. Positioning, Leveling, and Step 4. The Gas Supply Line Securing the Insert NOTE: Have the gas supply line installed in accordance Remote Control with local building codes by a qualified installer The receiver for the remotes must be installed BETWEEN approved and/or licensed as required by the locality. the base pan of the insert and the firebox of the wood-burn- (In the state of Massachusetts installation must be ing fireplace (see photo below). performed by a licensed
Resumen del contenido incluido en la página 19
Step 6. Wiring the Fireplace Step 5. Gas Pressure Requirements Pressure requirements for these gas appliances are shown NOTE: Electrical wiring must be installed by a li- in the table below. censed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- Pressure Natural Gas Propane SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- Minimum 5.0 inches 11.0 inches VENT ACCIDENTAL APPLIANCE OPERATION. Inlet Pressure w.c. w.c. For Standing Pilot Ignition Wiring Maximum Inlet 14.0 inches 14.0 inches A
Resumen del contenido incluido en la página 20
INSERT STRAIN RELIEF WARNING: MUST USE THE CORD SUPPLIED AROUND CORD IN THIS END ! FROM OUTSIDE OF UNIT WITH THE J-BOX. FEED PLUG THROUGH HOLE SIDEWALL Fan Option (FB-IN & FB-Grand ONLY) On units already installed removal of decorative front, sur- round and gas insert is required. • Detach flexible liner from back of unit. • Remove the four screws on the coverplate (see Figure 11). JUNCTION BOX • Bend up the tabs on the base pan (see Figure 10). • Place the blower in between the bend up tabs. SC