WarmHearth Fireplace
Installation Manual
Regency WarmHearth High Efficiency EPA Certified Fireplace MODEL: Z2510L
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
10/06/04
908-200
Resumen del contenido incluido en la página 2
Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. This product has been certified by the Environmental Protection Agency of the United States. This means that it meets the strictest standards in providing you with the latest in clean burning technology and efficiency. Specifications may vary widely. Consult with your Regency Dealer for local considerations. Keep those REGENCY FIRES bu
Resumen del contenido incluido en la página 3
TABLE OF CONTENTS Page Page Finishing the WarmHearth Safety Label Completing the Facing................................................ 17 Safety Label .......................................................................... 4 Non-Self Supporting, Thin Veneer Facades Installations ................................................................. 17 Masonry Kit Installation (Optional) .............................. 17 Installation Finishing Details ...........................................
Resumen del contenido incluido en la página 4
SAFETY LABEL This is a copy of the label that accompanies have printed a copy of the contents here for NOTE: Regency units are constantly being each Regency WarmHearth. It is located inside your review. improved. Check the label on the unit and if the lower louver opening on the left side. We there is a difference, the label on the unit is the correct one. Copy of Safety Label for Z2510L 4 Regency Z2510 WarmHearth
Resumen del contenido incluido en la página 5
INSTALLATION THE REGENCY WARMHEARTH 1) Optional 24 Karat Gold-plated Louvers 2) Clean Glass Air Wash System 3) High Safety Ceramic Glass 4) Optional 24 Karat Gold-plated Door 5) Andirons 6) Convection Air Inlet 7) Optional 150 CFM 2-speed Blower 8) Convection Chamber 9) Secondary Air Source 10) Primary Air Source 11) 7-inch Flue Pipe 12) High Heat Refractory Lining PRODUCT DETAILS OPTIONS EPA Certified YES, Phase 2 Emissions 5.2 Gms/Hr. Blower 150 CFM, 2 speed Efficiency (DEQ) 70.7% Central Forc
Resumen del contenido incluido en la página 6
INSTALLATION READ BEFORE YOU INSTALL 8) NEVER leave children unattended when DIMENSIONS AND there is a fire burning in the fireplace. THE REGENCY WARMHEARTH SPECIFICATIONS HIGH EFFICIENCY EPA 9) Allow the fireplace to cool before servicing. CERTIFIED FIREPLACE Always shut off any electricity to the fire- The WarmHearth is a woodburning fireplace place while working on it. This will prevent featuring a self-contained heat-circulating sys- This installation manual will enable you to make any poss
Resumen del contenido incluido en la página 7
INSTALLATION NOTE: normal construction materials. The chimney FAILURE TO USE PARTS MANU- requires a minimum 2 in. (50 mm) clearance. A FACTURED BY REGENCY FIRE- 1) Do not insulate the chase cavity with blown combustible mantle (to a depth of 10 in.) may be or fill type insulation materials. PLACE INDUSTRIES OR VARIA- installed no closer than 18 in. (457 mm) above the warm air vent. TIONS IN TECHNIQUES AND CON- 2) Local codes may not require firestopping at STRUCTION MATERIAL DESC
Resumen del contenido incluido en la página 8
INSTALLATION Note: If the fireplace is being cantilev- FRAMING DETAILS ered through an outside wall, the entire enclosure (floor, wall and Note: Ducting is tested at 1 in. clearance to framing for the first 6 feet and 1/2 in. false ceiling) up to the first ceiling thereafter and no stand-offs are required. level must be completely insulat- ed and vapor sealed and sheathed, to avoid transfer of cold air through the fireplace when not in use. LOCATION OF HEARTH EXTENSION FIREPLACE NOTE: When the u
Resumen del contenido incluido en la página 9
INSTALLATION In Canada: Chimney Height support as well as the floor beneath the hearth extension. Any factory built chimney listed and certified to The total height of your WarmHearth fireplace ULC-S629. Also any of the following chimney Note: The “Z” type safety strip is not system from the surface the fireplace rests on covered by ULC-S610 or ULC S604. supplied by Regency and must be to the chimney top must not exceed 36 ft. and fabricated locally. must also meet minimum system height ch
Resumen del contenido incluido en la página 10
INSTALLATION ASSEMBLY STEPS BEFORE YOU START Note: The following steps represent the Check your inventory list to be sure you have all the necessary parts supplied in good usable normal sequence of installation. condition. Check for any concealed damage. Check the operation of the combustion air damper. Each installation is unique, howev- When the damper is in the fully closed position, the damper handle should be to the right. When er, and might require different damper is in the fully open
Resumen del contenido incluido en la página 11
INSTALLATION uous floor or platform for support and to pre- result if stand-offs are not properly vent cold air from entering the room from under installed. the fireplace, if against an outside wall. The fireplace may be positioned and then the framing built around it, or the framing may be constructed and the fireplace positioned into the opening. The minimum ceiling height is 7 feet. When the and excessive heat output. The chimney unit is raised 4 inches above the floor the Regency Hearth Ex
Resumen del contenido incluido en la página 12
INSTALLATION b. Clear family members out of the area. TABLE 1 c. Call the fire department. REQUIRED FIRESTOP, RADIATION SHIELD, OR ATTIC INSULATION SHIELD d. Use a dry chemical fire extinguisher, Model 1st Floor 2nd Floor into Attic baking soda or sand to control the fire. Do not use water, it will create a AMERI-TEC 3103 Firestop Assembly (FSA) FSA with Attic Insulation Shield (AIS) steam explosion. GSW JFC Firestop/Radiation Shield (FRS) Firestop Attic Insulation S
Resumen del contenido incluido en la página 13
INSTALLATION WIRING THE WARMHEARTH INSTALLING THE OUTSIDE AIR KIT Field wire main power supply to fireplace for fan kit. (All electrical connections should only be performed by a licensed/certified electrician). Combustion air is fed to the firebox through a connection on the rear lower left side of the unit. CAUTION: Label all wires prior to dis- A free flowing supply of air must be available connection when servicing controls. to this opening at all times. Combustion air may Wiring errors
Resumen del contenido incluido en la página 14
INSTALLATION (Fastens to louvers) OPTION 2 ing the thermodisc to the fireplace. The 000-918 One-way Damper: holes are on the right hand side just External Blower with Thermo-Disc Eight inch diameter butterfly valve below the ashlip. necessary for external blower The thermodisc allows the fireplace to warm up installation. properly before the blower will switch on. The blower is also switched off if the fireplace The remainder of the components discussed temperature falls below suitable heating
Resumen del contenido incluido en la página 15
INSTALLATION 2) Metal ducting, grills and distribution box- 5) Install the connector collar into the unit Use high temperature silicone to seal the es. (Installer Supplied) making sure it is pushed all the way down. block-off plate to the unit. If necessary drill Reach through the upper louver opening extra holes in the plate and the unit and 3) Ducting is tested at 1 in. clearance to and snip and bend out the lower edge of the secure with extra screws. framing for the first 6 feet and 1/2 in.
Resumen del contenido incluido en la página 16
INSTALLATION be at the top so they lie flat. Bend out the 6) Connect the inlet of the blower to the outlet lower edge of the valve at 4 places inside of the valve using 8 inch diameter metal the fireplace with pliers so that it can't be ducting (rigid or flex). Any other size will pulled out again. Diagram 2. not work properly. 7) Duct-work can then be run to the desired rooms following good warm air distribution practices. Up to six 5 in. diameter runs can be installed from this system. Not
Resumen del contenido incluido en la página 17
INSTALLATION Extend unit past studs so it is flush FINISHING THE with sheeting. WARMHEARTH Completing the Facing Framing . . Facing materials must be thin veneer (non-self . . Do not restrict air flow supporting facades) or self supporting facades. through the inlet and . . . . If you are installing a thin veneer facade the outlet louvers of the fire- Regency Masonry Retainer Kit (Part # 000-920) place. This will cause . . Metal is recommended. All facades must be Non- . . overheating and possi
Resumen del contenido incluido en la página 18
INSTALLATION 4) Place side metal filler strips in between Example 2: stove and framing to cover the stand-off space. Fit the strips behind "A" so that they Face of Fireplace Flush with Wall Sheathing. cover the stand-offs, and will prevent mor- tar from falling through the mesh. 5) Center door arch edge, mark and drill holes. Note the top of the side pieces meet up with the edges of the center arch. Attach arch edge and bottom of grill edge to unit. The door arch floats at each end so that it ca
Resumen del contenido incluido en la página 19
INSTALLATION fit in order to prevent it from falling out when MASONRY LINER/ a fire is burning. BRICKS Insulated refractory panels are included to extend the life of the fireplace and help radiate heat more evenly. Make sure Insulating Paper is in place along the bottom, side and rear before bricks are put into place. Insulation batt, 1 in. thick is placed above the top brick baffle. Using the diagram to find the correct location of DOOR HANDLE the panels install in the following sequence: si
Resumen del contenido incluido en la página 20
MAINTENANCE 12)Green or wet wood is not recommended burn in many areas. Salt drift wood, CAUTION: Never leave unit unat- for your unit since most of the energy will chemically treated fire logs and pressure tended if door is left open. This be used to drive off the moisture instead of treated woods must not be burned in your procedure is for fire start-up only, heating your home. As well, green or wet woodstoves. as unit may overheat if door is left wood can result in dirty glass. 12) Do no