Resumen del contenido incluido en la página 1
WOOD
Fireplace
Insert &
www.regency-fi re.com
Hearth Heater
Owners & Installation Manual
MODELS: H2100 I3100L
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
908-332b FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
03/06/08
Resumen del contenido incluido en la página 2
Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning. SAFETY NOTE: If this Insert is not properly installed, a house fi re may result. For your safety, follow the installation instructions, contact local building or fi
Resumen del contenido incluido en la página 3
TABLE OF CONTENTS REGENCY FIREPLACE INSERTS & HEARTH HEATER SAFETY LABEL OPERATING INSTRUCTIONS Safety Label For I3100L ................................................4 First Fire ......................................................................13 Safety Label For H2100M..............................................5 Fan Operation (All Units) .............................................13 Ash Disposal................................................................13 Some Safety Guidelines
Resumen del contenido incluido en la página 4
SAFETY LABEL This is a copy of the label that accompanies each NOTE: Regency units are constantly being Regency Large Flush Insert. We have printed improved. Check the label on the unit and if a copy of the contents here for your review. there is a difference, the label on the unit is the correct one. SAFETY LABEL FOR I3100L 4 Regency Wood Insert & Hearth Heater DO NOT REMOVE THIS LABEL LISTED FACTORY BUILT FIREPLACE INSERT CERTIFIED FOR USE IN CANADA AND U.S.A. CAUTION MODEL: I3100L 106 T
Resumen del contenido incluido en la página 5
SAFETY LABEL This is a copy of the label that accompanies each NOTE: Regency units are constantly being Regency Hearth Heater. We have printed a improved. Check the label on the unit and if copy of the contents here for your review. there is a difference, the label on the unit is the correct one. SAFETY LABEL FOR H2100M Regency Wood Insert & Hearth Heater 5 (Duplicate Serial #) 103 DO NOT REMOVE THIS LABEL LISTED FACTORY BUILT FIREPLACE ACCESSORY HEARTH STOVE CAUTION CERTIFIED FOR USE IN CA
Resumen del contenido incluido en la página 6
INSTALLATION Regency Inserts are constructed with the high- 9) Inserts that project in front of the fi replace CHIMNEY est quality materials and assembled under strict must be supplied with appropriate supporting quality control procedures that insure years of means. SPECIFICATIONS trouble free and reliable performance. 10) Installer must mechanically attach the sup- plied label to the inside of the fi rebox of the Before installing, check and clean your chimney It is important that you read
Resumen del contenido incluido en la página 7
INSTALLATION Position the grill on the inside bodyface side and OPTIONAL FLUE fasten using the bolts, washers and nuts provided (2 per side) as shown in the diagrams. CONNECTOR KIT The optional Flue Connector Kit (Part # 846-527) and the Straight Flue Adaptor (Part #846-504) shown here, may be used to produce a secure connection between your fl ue connector and the insert collar. Detailed installation instructions are included with the kit. Note: The grill has a front and rear, the hol
Resumen del contenido incluido en la página 8
INSTALLATION LEG OPTION ON H2100 INSTALLATION INTO A In Canada this fi replace insert must be in- stalled with a continuous chimney liner of 6" HEARTH HEATER MASONRY FIREPLACE diameter extending from the fi replace insert to the top of the chimney. The chimney liner The addition of legs to the Hearth Heater does When referencing installation or connec- must conform to the Class 3 requirements not alter its certifi cation, it does not become a tion to masonry fi replaces or chimneys, the of CA
Resumen del contenido incluido en la página 9
INSTALLATION B) All units 4) If the fl oor of your fi replace is below the FACEPLATE AND TRIM level of the fi replace opening, adjust the insert's levelling bolts to accommodate the The unit may now be slid into fi nal position and Prior to sliding your insert into its fi nal position attached to the connection system. difference. When additional shimming is and attaching the connector or liner pipe, the required, use non-combustible masonry or faceplate side panel plates must be installed O
Resumen del contenido incluido en la página 10
White Low (Red) High (Black) INSTALLATION FAN / BLOWER Your fan should only be installed once the unit is 3) Slide the supports into the clips. The tension Do not turn fan ON until your insert has reached operating temperature or at least in place in order to prevent any damage to the holding the clips in place may be adjusted by fan. To attach, follow the instructions provided increasing or decreasing the offset spacing 30 minutes after starting fi re. with the fan. Make sure to install the r
Resumen del contenido incluido en la página 11
INSTALLATION FLOOR PROTECTION BRICK FLUE BAFFLE & SECONDARY AIR TUBE Please check to ensure that your fl oor protection and hearth will meet the standards for clearance INSTALLATION to combustibles. Your hearth extension must be made from a non-combustible material. The fl ue baffl e system located in the upper area of the fi rebox is removable to make cleaning your chimney system easier. The brick baffl es FIREBRICK ASSEMBLY must be installed prior to your fi rst fi re. Smoke spillage and dr
Resumen del contenido incluido en la página 12
INSTALLATION SCREEN DOOR Slide the rear of the baffl e on top of the rear Hearth Heater (H2100M) air channel in front of the locating tabs. Make Steel Baffl e Hook screen to the inside on the right side sure that the insulation is lying fl at and does of the fi rebox door opening. Lock in place by not obstruct the smoke from getting up the fl ue turning handle. Place the insulation batt on top of the baffl e. opening. Place hold down weights on top of Make sure that this batt is laying fl at
Resumen del contenido incluido en la página 13
OPERATING INSTRUCTIONS 10) For those units installed at higher elevations automatic temperature sensor will engage the FIRST FIRE or into sub-standard masonry fi replaces, blower when the unit is at temperature and will drafting problems may occur. Consult an shut off the blower once the fi re has gone out When your installation is completed and in- experienced dealer or mason on methods and the unit has cooled to below a useful heat spected, you are ready for your fi rst fi re. of increasing
Resumen del contenido incluido en la página 14
MAINTENANCE 6) Do not permit creosote or soot buildup in the Removal for Cleaning etc. DOOR LATCH chimney system. Check and clean chimney at regular intervals. Removal of your insert for cleaning purposes ADJUSTMENT is usually not required if a proper installation 7) Your Regency Insert can be very hot. You has been done. In the event that removal is re- The door latch may require adjustment as the may be seriously burned if you touch the quired, be sure not to damage any parts needed
Resumen del contenido incluido en la página 15
PARTS LIST I3100 MAIN ASSEMBLY Part # Description 846-910 Door Assembly-Large Gold (I3100)-no glass 846-916 Door Assembly-Large Black (I3100)-no glass 3) 846-304 Glass - Replacement - (I3100) 4) 936-243 7/8" Adhesive Tape Gasket 5) 846-920 Glass Retainer Clips (set of 8) 6) * Screw 1/4-20 x 3/8" 7) 948-172/P Glass Retainer - Large (I3100) 9) 846-973 Door Handle Assembly 16) 846-570 Med. Density Door Gasket Kit 17) 846-918 Hinge Caps (2/set) 19) 948-101 Spring Handle - Large 2
Resumen del contenido incluido en la página 16
PARTS LIST I3100 FACEPLATES Part # Description Faceplate: I3100L 163-910 Faceplate & Trim Set - Regular 385) 163-165 Trim Right Regular 386) 163-160 Trim Top Regular 387) 163-161 Trim Left Regular 388) * Faceplate Side Regular 389) * Faceplate Top Regular 163-912 Faceplate & Trim Set - Oversize 395) 163-164 Trim Right Oversize 396) 163-162 Trim Top Oversize 397) 163-163 Trim Left Oversize 398) * Faceplate Side Oversize 399) * Faceplate Top Oversize *Not available as a replacem
Resumen del contenido incluido en la página 17
PARTS LIST H2100 MAIN ASSEMBLY Part # Description Part # Description 37) 836-212 Baffl e Insulation 1) 846-910 Door Assembly-Large Gold - no glass 38) * Insulation Weights 846-916 Door Assembly-Large Black - no glass 39) 120-950 Steel Baffl e 3) 846-304 Glass - Replacement 948-216 Regency Logo 4) 936-243 7/8" Adhesive Tape Gasket 5) 846-920 Glass Retainer Clips (set of 8) Faceplate: H2100M 6) * Screw 1/4-20 x 3/8" 120-910 Faceplate & Trim Set - Regul
Resumen del contenido incluido en la página 18
PARTS LIST I3100 & H2100 FIREBRICK Part # Description 70) 902-111 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 71) 802-104 Brick Partial: 1-1/4" x 4" x 9" 72) 802-146 Brick Partial: 1-1/4" x 1-3/4" x 9" 75) 802-139 Brick Partial: 1-1/4" x 4" x 8-3/4" 76) 802-152 Brick Partial: 1-1/4" x 2" x 9" 78) 802-143 Brick Partial: 1-1/4" x 2-1/4" x 2-1/4" 81) 802-135 Brick Partial: 1-1/4" x 1-1/4" x 9" 84) 802-107 Brick Partial: 1-1/4" x 4-1/2" x 8" 85) 802-156 Brick Part
Resumen del contenido incluido en la página 19
WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product. This warranty is not transferable. The Warranty: Lifetime Covered under the agreement are the following components: Firebox, ceramic baffl e, vermi
Resumen del contenido incluido en la página 20
Regency fi replace products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thor- oughly before it leaves our door. Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency Product. See the inside back cover for details. Register your Regency online at http://www.regency-fi re.com Installer: Please complete the following information