Resumen del contenido incluido en la página 1
www.regency-fi re.com
Owners &
G36D Zero Clearance Direct Vent Gas Fireplace
Installation Manual
MODELS: G36D-NG1 Natural Gas G36D-LP1 Propane
WARNING: If the information in these instructions are not followed exactly,
FOR YOUR SAFETY
a fi re or explosion may result causing property damage, personal injury
What to do if you smell gas:
or loss of life.
FOR YOUR SAFETY: Do not store or use gasoline or other fl ammable
Do not try to light any appliance.
vapors and liquids in th
Resumen del contenido incluido en la página 2
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by FIREPLACE PRODUCTS INTERNATIONAL. The G36D is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model G36D has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow
Resumen del contenido incluido en la página 3
TABLE OF CONTENTS SAFETY LABEL OPERATING INSTRUCTIONS Safety Label ..................................................................4 Operating ....................................................................34 Instructions ..................................................................34 Lighting Procedure ......................................................34 INSTALLATION Shutdown Procedure ...................................................34 First Fire ............................
Resumen del contenido incluido en la página 4
SAFETY LABEL This is a copy of the label that accompanies each G36D Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open. ® NOTE: UltraGlow units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. W all For the State of Massachusetts, installation and repa
Resumen del contenido incluido en la página 5
INSTALLATION 14) Under no circumstances should any solid IMPORTANT MESSAGE CLOTHING OR OTHER FLAMMABLE fuels (wood, paper, cardboard, coal, etc.) MATERIAL SHOULD NOT BE PLACED be used in this appliance. SAVE THESE ON OR NEAR THE APPLIANCE. INSTRUCTIONS 15) The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids). The G36D-NG1 or G36D-LP1 Direct Vent GENERAL SAFETY Fireplace must be installed in accordance Emissions fr
Resumen del contenido incluido en la página 6
INSTALLATION This includes: 5) This appliance is Listed for bedroom MANUFACTURED installations when used with a Listed Millivolt 1) Clocking the appliance to ensure the correct Thermostat. Some areas may have further MOBILE HOME fi ring rate (rate noted on label 26,000 Btu/h) requirements, check local codes before after burning appliance for 15 minutes. ADDITIONAL installation. REQUIREMENTS 2) If required, adjusting the primary air to ensure 6) The G36D Direct Vent Gas Fireplace is that
Resumen del contenido incluido en la página 7
INSTALLATION 2) Frame in the enclosure for the unit with CLEARANCES MANTEL LEG framing material. The framed opening is 37-1/4" high x 36-1/4" wide x 17-3/8" deep CLEARANCES The clearances listed below are Minimum (946mm high x 921mm wide x 441mm distances unless otherwise stated: deep). Combustible mantel leg clearances as per diagram below: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest imp
Resumen del contenido incluido en la página 8
INSTALLATION COMBUSTIBLE MANTELS Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board. These drawings are to scale at 1:6 (one inch = 6 inches) Mantel can be installed anywhere in shaded area or higher using the above scale. Note: Ensure the pai
Resumen del contenido incluido en la página 9
INSTALLATION 3) Attach the standoff securely to the top T o p Header with 2 screws per standoff (on opposite 10" dia. hol e corners). through wall 1/2" for Fle x Drywal l or for DuraV ent "C" Screw Position: For a facing material depth of 1-1/4" 2" (32mm), the top facing support must be reversed. 3-1/2" 4" 17-1/8" Opening for gas connectio n Note: 40-1/2" (1029mm) is the minimum height for both fl ex termination or Simpson Dura-Vent venting. Top Facing Support and Side Nailing Strips 5) Th
Resumen del contenido incluido en la página 10
INSTALLATION EXTERIOR VENT TERMINATION LOCATIONS ® ® ® 10 UltraGlow G36D Zero Clearance Direct V G36D Zero Clearance Direct Vent Gas Fireplace ent Gas Fireplace V V . V ertical Inside corner det ail T ermination V ertical T ermination G V A 24" 24" 18" D V E H B B C M Fixed B V V Closed Openable Fixed Closed V Openabl e V F N B L V A B K V A B j A Air supply outlet Area where terminal is not permited V ent terminal A V A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) H
Resumen del contenido incluido en la página 11
INSTALLATION VENTING ® ® ® ® UltraGlow UltraGlow UltraGlow Direct V Direct Vent System (Flex) ent System (Flex) Horizontal Terminations Only These venting systems, in combination with the G36D Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior Vent Termination Locations" section. ® ® ® ® UltraGlow UltraGlow UltraGlo
Resumen del contenido incluido en la página 12
INSTALLATION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI. ® Description Simpson Dura-Vent Selkirk Amerivent Security ® TM ® Direct VentGS Direct-Temp Direct Vent Secure Vent 6" Pipe Length, Galvanized 908 4DT-6 N/A SV4L6 6" Pipe Length, Black 908B 4DT-6B N/A SV4LB6 7" Pipe Length, Galvanized N/A N/A 4D7 #N/A 7" Pipe Length, Black
Resumen del contenido incluido en la página 13
INSTALLATION RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations The minimum components required for a basic horizontal termination Flat Wall Installation are: Wall Thickness Vent Length Required (inches) (inches) 1 Horizontal Termination Cap o 4" - 5-1/2" 6" 1 90 Elbow 1 Rigid Pipe Adaptor 7" - 8-1/2" 9" 1 Wall Thimble 10" - 1-1/2" 12" 1 Length of pipe to suit wall thickness (see chart) 9" - 14-1/2" 11" - 14-5/8" Adj. Pipe Wall thickness is measured from the back standoffs
Resumen del contenido incluido en la página 14
INSTALLATION RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS ® ® ® ® UltraGlow UltraGlow UltraGlow DIRECT VENT SYSTEM (FLEX) DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) o o o The diagram shows all allowable combinations of vertical runs with horizontal terminations, using using one one 90 90 elbow (two 45 elbows equal one 90 elbow). Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid vent systems. All Rigid Pipe Systems All Rigid Pipe Systems 4" inner
Resumen del contenido incluido en la página 15
INSTALLATION RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS ® ® ® ® UltraGlow UltraGlow UltraGlow DIRECT VENT SYSTEM (FLEX) DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) o o o The diagram below shows examples of horizontal termination arrangements using two 90 elbows (two 45 elbows equal one 90 elbow). o Note: 1) A maximum of two 90 elbows are permitted. o 2) A minimum of 6 ft. (1.8m) vertical from base of unit is required if two 90 elbows are used. 3) Minimum distance between
Resumen del contenido incluido en la página 16
INSTALLATION RIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS (Propane & Natural Gas) The G36D is approved for a maximum 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset o o o using two 90 elbows (two 45 elbows equal one 90 elbow) with Rigid Pipe vent systems for Propane and Natural Gas, as per diagram 1. The G36D is approved for a maximum 37 ft. (11.3m) straight vertical, including a maximum 20" (0.5m) horizontal o o o offset using two 90 elbow (two 45 elb
Resumen del contenido incluido en la página 17
INSTALLATION The G36D is approved for a maximum 37 ft. (11.3m) straight vertical, with Rigid Pipe vent systems for Propane and Natural Gas, as per the diagram 3. The shaded area in the diagram 3 shows all allowable combinations of straight vertical and offset to vertical terminations with Rigid Pipe vent systems for o Propane and Natural Gas. Maximum two 45 elbows allowed. • Vent must be supported at offsets • Firestops are required at each fl oor level and whenever passing through a wall.
Resumen del contenido incluido en la página 18
INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE Masonry chimneys may take various contours which the fl exible liner will accommodate. However, CONNECTED TO A CHIMNEY FLUE keep the fl exible liner as straight as possible, avoid unnecessary bending. SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. The Air Intake pipe must be attached to the inlet air collar of the termination cap. This appliance is designed to be attached to two 3" (76mm) co-linear alumini
Resumen del contenido incluido en la página 19
INSTALLATION VENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations. ® UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 19
Resumen del contenido incluido en la página 20
INSTALLATION UNIT INSTALLATION b) Horizontal runs of vent must be supported every three feet. Wall straps WITH HORIZONTAL are available for this purpose. TERMINATION 5) Mark the wall for a 10" x 10" square hole. Install the vent system according to the The center of the square hole should line up with the centerline of the horizontal pipe. manufacturer's instructions included with the components. Cut and frame the 10 inch square hole in the exterior wall where the vent will be termi