Resumen del contenido incluido en la página 1
1
INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PAR-
TICULATE EMISSION STANDARDS BY E.E.M.C. THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS: CSA B366.2 , ULC
S627, ULC S628, UL 1482. MODEL 1100 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES.
INSTALLATION AND OPERATION INSTRUCTIONS FO
Resumen del contenido incluido en la página 2
2 TABLE of CONTENTS PG 2-4 INTRODUCTION 10-11 FINISHING Warranty Brick Installation General Information Ornamental Trivet Installation Care of Plated & Enamelled Parts Door and Handles Installation Care of Glass Pedestal Trim Installation 5-6 INSTALLATION Optional Ash Drawer Kit Installing the Legs 11-13 OPERATION Alcove Installation Achieving Proper Draft Stove Installation Fire Extinguishers and Smoke Detectors Chimney Connection Fuel Loading and Burn Cycle Adding Chimney Sections Flash Fire O
Resumen del contenido incluido en la página 3
3 NAPOLEON products are manufactured under the strict Standard of the World Recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON. NAPOLEON WOOD FIREPLACE PRESIDENT'S LIFETIME
Resumen del contenido incluido en la página 4
4 PEDESTAL MODELS ONLY GENERAL INFORMATION If the outside air feature of the stove is utilized, you should Except for their different depths, models 1100, 1150, 1400, never experience a shortage of combustion air. If you 1900 and the fireplace inserts 1101, 1401, and 1402 are choose not to utilize outside air and experience draft or identical and use the same burning principles. They were smoking problems, you may need to open a door or win- specifically designed over many months of research to
Resumen del contenido incluido en la página 5
5 STOVE INSTALLATION INSTALLING THE LEGS STOVE INSTALLATION If the stove is to be installed on a To avoid being damaged during shipping, the stove has combustible floor, it must be placed been bolted to the pallet and must be unbolted before the on an approved non-combustible stove can be installed. FIGURE 2A hearth pad, that extends 8" (200mm) 1. Remove the 4 nuts and beyond the stove sides and back, washers from the underside of and 18" (455mm) to the front. It must the pallet. be installed wi
Resumen del contenido incluido en la página 6
4.5" 6 THE TOTAL HORIZONTAL VENT LENGTH PEDESTAL MODELS OUTSIDE AIR SHOULD NOT EXCEED 40% OF THE CHIMNEY If possible connect the air intake HEIGHT ABOVE THE STOVE. at the pedestal's back or bottom All horizontal smoke pipe must slope slightly to the outside with a 4 inch (100mm) diameter fresh air kit upwards a minimum of 1/4" per foot (6mm/ available at your Napoleon/Wolf 0.3m) and all connections must be tight and Steel Ltd. dealer. Follow detailed secured by three sheet metal screws equally i
Resumen del contenido incluido en la página 7
7 HINT FOR INSTALLING PORCELAIN FIGURE 11 ENAMEL INSERTS: Ensure the base of the porcelain side panels It must be installed between are protected from rubbing against the hearth ceiling joists, with radiation when sliding your insert into the masonry shield and roof flashing, so that fireplace. the structural strength, insula- tion and waterproof qualities of PRIOR TO INSTALLATION the home are not lessened. Clean all ashes out of the inside of the fireplace. Make Seal with silicone to maintain a
Resumen del contenido incluido en la página 8
8 In the United States: While it is not required, it is rec- ommended that a chimney liner be installed that is con- OPTIONAL BLOWER tinuous from the insert to the top of the chimney, particu- larly when the insert is installed in a basement. For this Drywall dust will penetrate into the blower bearings, type of connection, use the "In Canada" installation instruc- causing irreparable damage. Care must be taken to pre- tions above. vent drywall dust from coming into contact with the In the Unite
Resumen del contenido incluido en la página 9
9 3. The access panel can be removed by taking out the 8 1150 BLOWER INSTALLATION #10 self taping screws. A 5/16" nut driver will be required to complete this job. Unplug wires from the thermal switch 1. Remove the on the panel. See FIGURE 15. knock-out from 4. Remove the securing wingnut from the blower mounting the back of the bracket, slide the bracket to the right and rotate the left side fireplace. of the assembly out of the cavity to clear the blower motor. 2. Install the blower Disconnect
Resumen del contenido incluido en la página 10
10 FINISHING 1100/1100C/ 1101 1400/1400L 1401 1900 1100L/1150 SIZES 4-#1 4-#1 4-#1 4-#1 4-#7* #1. 1-1/4" x 4"-1/2 x 9" BACK 2-#4 2-#4 2-#4 2-#4 2-#2 #2. 1-1/4" x 3" x 9" #3. 1-1/4" x 4-1/2" x 4-1/2" 8-#1 8-#1 12-#1 12-#1 12-#7* SIDES 2-#3 2-#3 2-#3 #4. 1-1/4" x 4-1/2" x 9" 2-#4 #5. 1-1/4" x 2-1/2" x 4-1/2" (notched) #6. 1-1/4" x 1-1/2" x 4-1/2" 2-#10 2-#10 2-#11 2-#11 2-#12 #7. 1-1/4" x 4-1/2" x 9" TOP 2-#13 * (light weight) 3-#1 4-#1 5-#1 6-#1 7-#7* #8. 1-1/4" x 2-1/4" x 9" 2-#2 2-#2 2-#2 2-#
Resumen del contenido incluido en la página 11
11 BRICKS AND BAFFLES INSTALLATION OPTIONAL ASH DRAWER KIT With stove and chimney installation completed, move the Models 1100L / 1400L Only: Provisions have been made bricks into place by working as illustrated for your unit on on the stove to install an optional ash drawer kit. The EPAD- page 10. KT kit allows for convenient removal of excess ash. This kit 1. Install two or three courses of brick on both sides of the can be purchased through your Napoleon Dealer. unit. Install two courses on
Resumen del contenido incluido en la página 12
12 You can now add larger pieces of wood and operate the FIRE EXTINGUISHERS / SMOKE DETECTORS stove normally. Once the stove/insert is entirely hot, it will burn very efficiently with little smoke from the chimney. There All homes with a solid fuel burning fireplace should have at will be a bed of orange coals in the firebox and secondary least one fire extinguisher in a central location known to all, flames flickering just below the top firebrick. You can safely and at least one smoke detector
Resumen del contenido incluido en la página 13
13 SMOKING MAINTENANCE A properly installed Napoleon unit should not smoke. If yours Check your chimney and chimney connector for creosote and does, check the following: Has the chimney had time to get soot buildup weekly until a safe frequency for cleaning is estab- hot? Is the smoke passage blocked anywhere in the stove, lished. If accumulation is excessive, disconnect the stove and chimney connector or chimney? Is the room too airtight and clean both the chimney and the stove. You may want to
Resumen del contenido incluido en la página 14
14 DOOR REMOVAL (1100C ONLY) DO'S 1. Build a hot fire 1. Remove cast top. 2. Use only dry wood. 2. Pull pin from top door hinge. It is important to hold the 3. Several pieces of medium sized wood door while removing the pin. Pivot the door to clear the top are better than a few big pieces. door hinge. Lift the door off of the lower pin. Do not pivot the 4. Clean chimney regularly. door any further than necessary. 5. Refuel frequently using medium sized wood. 6. "Fine Tune" the air settings for o
Resumen del contenido incluido en la página 15
15 REPLACEMENTS Contact your dealer for questions concerning prices and 1. MODEL & SERIAL NUMBER OF FIREPLACE availability of replacement parts. Normally all parts can be 2. INSTALLATION DATE OF FIREPLACE ordered through your Napoleon dealer or distributor. 3. PART NUMBER When ordering replacement parts always give the follow- 4. DESCRIPTION OF PART ing information: 5. FINISH FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE * IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR ORIGINAL INVOIC
Resumen del contenido incluido en la página 16
16 ACCESSORIES 1100L COMPONENTS # PART NO. DESCRIPTION 57 H222G GOLD PLATED DOOR 66 EP62-1 VARIABLE SPEED BLOWER 57 H222 BLACK DOOR 77 EPA-RK SOLID BRASS RAILING KIT 57 H222SS BRUSHED STAINLESS STEEL DOOR 78* EPLK AIR CIRCULATION CHAMBER LOUVRES (BLACK) - STANDARD ARCH 79* EPLG AIR CIRCULATION CHAMBER LOUVRES (GOLD) 58 H222W BLACK DOOR - EARLY AMERICAN 80* EPLSS AIR CIRCULATION CHAMBER LOUVRES 58 H222GW GOLD DOOR - EARLY AMERICAN (BRUSHED STAINLESS STEEL) 58 H222SSW BRUSHED STAINLESS STEEL DOOR
Resumen del contenido incluido en la página 17
EM3030L-167 zr-2 115V 60Hz 46W Z.P. Ins. ClassB SEL 073 17 16 15 12 74 10 14 33 19 30 32 16 39 44 54 17 18 31A 31 77 53 46 38 40 52 58 47 85 49 1 48 57 84 83 20 55 65 59 56 2 62 63 76 72 73 64 66 81 W415-0512 /C 10.02.06
Resumen del contenido incluido en la página 18
18 W415-0512 / C 10.02.06 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage. Service Technician Date Dealer Name Service Performed Special Concerns Name
Resumen del contenido incluido en la página 19
19 NOTES W415-0512 /C 10.02.06
Resumen del contenido incluido en la página 20
20 NOTES W415-0512 / C 10.02.06