Resumen del contenido incluido en la página 1
7000 SERIES
SUPER B-VENT GAS FIREPLACE
INSTALLATION AND OPERATING INSTRUCTIONS
MODELS: 724BV(4536,5142)(N,P)(V,E)B
WARNING: If the information in these
instructions are not followed exactly, a fire or
explosion may result causing property
damage, personal injury or death.
⎯ Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
⎯ WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
DUE TO HIGH TEMPERATUR
Resumen del contenido incluido en la página 2
T TA AB BL LE E O OF F C CO ON NT TE EN NT TS S IMPORTANT SAFETY INFORMATION:..............................................................................................................2 PRODUCT SPECIFICATIONS: ...............................................................................................................................3 HIGH ALTITUDE INSTALLATIONS ............................................................................................................................
Resumen del contenido incluido en la página 3
I IM MP PO OR RT TA AN NT T S SA AF FE ET TY Y I IN NF FO OR RM MA AT TI IO ON N IMPORTANT SAFETY INFORMATION: INSTALLER: Please leave these instructions with the owner. OWNER: Please read and retains these instructions for future reference. IMPORTANT: Read these instructions carefully before installing or trying to operate this appliance. • DO NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to re
Resumen del contenido incluido en la página 4
P PR RO OD DU UC CT T S SP PE EC CI IF FI IC CA AT TI IO ON NS S/ /L LI IS ST TI IN NG G & & C CO OD DE E A AP PP PR RO OV VA AL L PRODUCT SPECIFICATIONS: Gas Pressure (Inches W.C.) Models Number Gas Type Control Type Max Btu Max Min Manifold 724BV4536NV Natural Gas Milli-volt 50000 10.5 4.0 3.5 724BV4536PV Propane/LPG Milli-volt 50000 13.0 11.0 10.0 724BV5142NV Natural Gas Milli-volt 50000 10.5 4.0 3.5 724BV5142PV Propane/LPG Milli-volt 50000 13.0 11.0 10.0 724BV4536NE Natura
Resumen del contenido incluido en la página 5
P PR RE E- -I IN NS ST TA AL LL LA AT TI IO ON N I IN NF FO OR RM MA AT TI IO ON N PRE-INSTALLATION INFORMATION: Before You Start: Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Contents: • Fireplace – Firebox and Burner system • Set of Logs • Lava Rock • Rock Wool • Exterior out
Resumen del contenido incluido en la página 6
P PR RE E- -I IN NS ST TA AL LL LA AT TI IO ON N I IN NF FO OR RM MA AT TI IO ON N Figure 1: Fireplace Dimensions 5
Resumen del contenido incluido en la página 7
P PR RE E- -I IN NS ST TA AL LL LA AT TI IO ON N I IN NF FO OR RM MA AT TI IO ON N Figure 2: Fireplace Locations and Minimum Clearances Requirements CAUTION: Measure fireplace dimensions and verify framing methods & wall covering details before framing construction begins. 6
Resumen del contenido incluido en la página 8
P PR RE E- -I IN NS ST TA AL LL LA AT TI IO ON N I IN NF FO OR RM MA AT TI IO ON N Figure 3: Wall & Ceiling Minimum Clearances Wall and Ceiling Clearance Requirements: Ensure that minimum clearances shown in Figure 3 are maintained. Left and right clearances are determined when facing the front of the appliance. Follow these instructions carefully to ensure safe installation. Failure to follow these requirements may create a fire hazard. Sidewall Clearance: The clearance from the fr
Resumen del contenido incluido en la página 9
P PR RE E- -I IN NS ST TA AL LL LA AT TI IO ON N I IN NF FO OR RM MA AT TI IO ON N Mantel Clearances: If a combustible mantel is installed, it must meet the clearance requirements detailed in Figure 4. Figure 4: Mantel Clearance Floor Clearances: The fireplace may be installed on a flat, hard combustible surface (i.e. flat wood, plywood, or particleboard). Be sure that the fireplace rests on a solid continuous floor or platform with appropriate framing support. Do NOT instal
Resumen del contenido incluido en la página 10
P PR RE E- -I IN NS ST TA AL LL LA AT TI IO ON N I IN NF FO OR RM MA AT TI IO ON N CAUTION Measure fireplace dimensions and verify framing methods & wall covering details before framing construction begins. Finishing Material: NOTE Any remote wiring (i.e. remote control, wall switch or 120 volt wiring) must be done prior to final finishing to avoid costly reconstruction. Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating of Z
Resumen del contenido incluido en la página 11
V VE EN NT T I IN NS ST TA AL LL LA AT TI IO ON N VENT INSTALLATION: WARNING The following venting instructions are provided as a general guideline. Always check with pipe manufacturer for venting requirements. Positioning The Fireplace: NOTE The fireplace must be installed giving full consideration to the clearance and height requirements identified in this manual. 1. Bend out the four (4) nailing flanges located on the sides of the fireplace. For 5/8” drywall use the two (
Resumen del contenido incluido en la página 12
V VE EN NT T I IN NS ST TA AL LL LA AT TI IO ON N WARNING Never use more than two (2) 45 degree elbows. When using adjustable elbows, never exceed 45 degrees. Vertical Venting with Two (2) 45 Degree Elbow: NOTE V1 and V2 must satisfy this condition: V1 + V2 < 40 feet Max. V1 + V2 > 14 feet Min. Figure 7: Horizontal Venting with Two (2) 45 Degree Elbow INSTALLING VENT COMPONENTS Before You Start: Plan your installation. Set unit in place and survey how best
Resumen del contenido incluido en la página 13
V VE EN NT T I IN NS ST TA AL LL LA AT TI IO ON N Figure 8: Installing Pipe Supports WARNING Always maintain minimum clearances around vent systems. The minimum clearances to combustibles is 1” around vent pipe. For ceiling firestops and vertical sections of vent pipe a 1-inch minimum clearance all around the pipe must be maintained. Do not pack the open air spaces with insulation or other materials. This could cause high temperatures and may present a fire hazard. NOTE A cei
Resumen del contenido incluido en la página 14
V VE EN NT T I IN NS ST TA AL LL LA AT TI IO ON N Figure 9: Ceiling Firestop Location Vent Termination: For Vertical Termination ` Figure 10: Minimum Vent Height for Various Roof Pitches WARNING Major building codes specify a minimum vent height above the rooftop depending on the pitch of the roof. Refer to the above figure for minimum heights, provided the termination cap is at least eight (8) feet from a vertical wall, and two (2) feet below a horizontal overha
Resumen del contenido incluido en la página 15
V VE EN NT T I IN NS ST TA AL LL LA AT TI IO ON N NOTE When working on the roof, cover the opening of the installed vent pipes below to prevent debris falling in. To Locate and install Vertical Termination • Locate and mark the vent center point on the underside of the roof, and drive a nail through the center point. • The size of the roof hole framing dimensions depends on the pitch of the roof • Cut and frame the roof hole. • Continue to install vent sections through the roof
Resumen del contenido incluido en la página 16
G GA AS S L LI IN NE E A AN ND D E EL LE EC CT TR RI IC CA AL L I IN NS ST TA AL LL LA AT TI IO ON N GAS LINE AND ELECTRICAL Gas Line Installation: NOTE Plumbing connections should only be performed by a qualified, licensed plumber. Main gas supply must be off when plumbing gas line to fireplace or performing service. • Consult all codes. All gas piping must be installed to comply with local codes, or in the absence of local codes, with the latest edition of the National Fuel G
Resumen del contenido incluido en la página 17
G GA AS S L LI IN NE E A AN ND D E EL LE EC CT TR RI IC CA AL L I IN NS ST TA AL LL LA AT TI IO ON N Figure 12: Gas Pressure Check at Gas Valve Electrical Wiring: Standing Pilot Ignition Wiring-Millivolt Control: WARNING Do not connect 110-120 VAC to the Remote Wall Switch, DC Remote Control or the Millivolt Control Valve. The appliance will malfunction or the valve will be damaged. CAUTION Electrical connections should only be performed by a qualified, licensed electri
Resumen del contenido incluido en la página 18
G GA AS S L LI IN NE E A AN ND D E EL LE EC CT TR RI IC CA AL L I IN NS ST TA AL LL LA AT TI IO ON N Figure 13: Wiring Diagram for Standing Pilot - Millivolt System Optional DC Remote Systems These instructions supersede the section entitled “Hearth Mount” in the Millivolt hand held remote instructions supplied with the remote. NOTE Remote receiver must be mounted outside the appliance, due to high temperatures inside the chamber. This will prevent failures and longer batt
Resumen del contenido incluido en la página 19
G GA AS S L LI IN NE E A AN ND D E EL LE EC CT TR RI IC CA AL L I IN NS ST TA AL LL LA AT TI IO ON N Pilot must be lit and the valve control knob turned to the “ON” position. Meter leads must be connected to the TP and the TH/TP terminals on the control valve. • Turn RS-ON-OFF switch to the “ON” position. If meter is reading more than 175 millivolt and the main burner does not come on, then replace control valve. If meter is reading less than 175 millivolt, then refer to TROUBLESH
Resumen del contenido incluido en la página 20
G GA AS S L LI IN NE E A AN ND D E EL LE EC CT TR RI IC CA AL L I IN NS ST TA AL LL LA AT TI IO ON N Optional DC Remote Systems These instructions supersede the section entitled “Hearth Mount” in the Millivolt hand held remote instructions supplied with the remote. NOTE Remote receiver must be mounted outside the appliance, due to high temperatures inside the chamber. This will prevent failures and longer battery life. 1. Plug in the remote connector wire to the remote receiver.