Resumen del contenido incluido en la página 1
CARE AND OPERATION INSTRUCTIONS
B-Vent Gas
Fireplace Heater Inserts
P/N 775,155M Rev. E, 12/2007
Installer: Leave This Manual With The Appliance.
Consumer: Retain This Manual For Future Reference.
A French manual is available upon request. Order P/N 775,155CF.
US
Models: EBVI25 & EBVI30
Ce manuel d’installation est disponible en francais, simplement
en faire la demande. Numéro de la pièce 775,155CF. Report No. 116-F-15-5
WARNINGS
• Hot! Do not touch! The glass and surfaces of this appli
Resumen del contenido incluido en la página 2
IMPORTANT SAFETY AND WARNING WARNING WARNING INFORMATION Carbon Monoxide Poisoning: Do not use these appliances if Early signs of carbon monoxide any part has been under water. READ THIS MANUAL IN ITS poisoning are similar to the flu Immediately call a qualified, ENTIRETY AND UNDER-STAND with headaches, dizziness and/or professional service technician THESE RULES TO FOLLOW FOR nausea. If you have these signs, to inspect the appliances and to SAFETY. obtain fresh ai
Resumen del contenido incluido en la página 3
Input of millivolt model is variable. The rates CONGRATULATIONS ON THE PURCHASE OF YOUR NEW GAS APPLIANCE MANU- areshown in the following table: FACTURED BY LENNOX HEARTH PRODUCTS. When you purchased your new gas-fired heater, you joined the ranks of thousands of Millivolt Models with individuals whose answer to their home heating needs reflects their concern for efficiency MAnnually-Modulated Gas Valves and our environment. We extend our continued support to help you achie
Resumen del contenido incluido en la página 4
T O O W O L I P O N O L T H N GAS CONTROLS CONTROL COMPARTMENT ACCESS Test gauge connections are provided on the front of the millivolt gas control valve (identi- These millivolt appliances are fitted with a burner Pull down hinged door to access control fied IN for the inlet and OUT for the manifold compartment (see Figure 3). side).See Figures 1 & 2. Off/On Switch, located on the side surround panel as shown in Figure 4 on Page 4. Once t
Resumen del contenido incluido en la página 5
OPERATION AND CARE OF YOUR WARNING APPLIANCE IMPORTANT Turn off gas and electrical power Do not use abrasive cleaners Appliance operation may be controlled before servicing the appliance. through a remotely located optional wall on glass. Never clean the glass thermostator remote control. when it is hot. In lieu of remote control or remote wall thermo- CAUTION stat operation, the appliance must be operated WARNING directly through the off
Resumen del contenido incluido en la página 6
6. (Model EBVI25) Remove the two hex 7. Disconnectwires from the blower . head boltsshown in Figure 7. CAUTION 8. Lift blower up and pull it out from back (Model EBVI30) Remove the two opening of firebox (see Figure 9). screwsshown in Figure 8,then lift Label all wires prior to discon- 9. To reinstall blower, reverse Steps 1 outair duct channel. nection when servicing con- through 8. trols. Wiring errors can caus
Resumen del contenido incluido en la página 7
MAINTENANCE Annually(Before the onset of the Burning Season) Maintenance Task Accomplishing Person Procedure Inspecting/CleaningBurner ,Logs QualifiedSer viceT echnician Inspect valve and ensure it is properly operating. Check piping andControls for leaks. Vacuum the control compartment, fireplace logs and burnerarea. Check Flame Patterns and Flame Qualified Service Technician Refer to Figure 13 on Page 8 and verify the flame pattern a
Resumen del contenido incluido en la página 8
Firebox Floor BURNER ADJUSTMENT PROCEDURE FOR REMOVING STANDARD GLASS DOOR ASSEMBLY Flame Appearance and Sooting Proper flame appearance is a flame which is blue at the base and becomes yellow/orange in the top of the flame. When the insert is first lit, the entire WARNING flame may be blue and will graduallay turn yellow/orange during the first 6-8 minutes of operation. If after 6-8 minutes the flame stays blue, or if Handle gla
Resumen del contenido incluido en la página 9
Burner Adjustment Procedure CAUTION WARNING Carbon will be produced if the air shutter is closed too much. Any damage due to carboning resulting from improperly setting the air Air shutter adjustment should shutter is not covered under the warranty. only be performed by a qualified professional service technician. The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation. CAUTION Air Shutter Adjustment Gu
Resumen del contenido incluido en la página 10
1. Place the rear log onto the two corresponding locating pins at the 4. Place the Front Left Log onto the two corresponding locating pins back of the fireboxas shown in Figure 16. asshown in Figure 19. Figure 16 Rear Log FrontLeft Log Figure 19 . Place the Front Right Log onto the two corresponding locating pins 5. Install the Top Left Log onto the corresponding locating pin and asshown in Figure 17. indentation on Cen
Resumen del contenido incluido en la página 11
Embers Figure 23 9. Place some vermiculite around the logs as shown in Figure 24 (the entire bag of vermiculite willNOT be used). Top Right Log Figure 22 8. Place the glowing embers on the burner as shown in Figure 23. One package of ember material has been included with this log set You will notneed to use the entire bag. IMPORTANT: The quantity and placement of the ember material can affect insert performance therefore it is ver
Resumen del contenido incluido en la página 12
MILLIVOLT APPLIANCE CHECKOUT FIREPLACE REQUIREMENTS Room Air Circulation Blower Light the pilot by following the instructions on IMPORTANT: When installing this appliance IMPORTANT: BLOWER GROUND WIRE Page 15 or 16of thismanual. into a factory built fireplace or heatform, the air WITH POWER CORD GREEN WIRE flow within and around the fireplace shall not SHOULD BE ATTACHED TO THE GROUND The pilot flame should be steady, not lifting be altered by
Resumen del contenido incluido en la página 13
TH TH TP TP P A Deluxe Remote Control System Screen Door Kit SIT & Honeywell The Model RCL-T (Deluxe) Remote Control Millivolt Wiring Diagram These decorative screen door panels fit over System has all of the features of the standard the standard glassdoor panels. system along with an added easy to read LCD If original wire as supplied must be replaced, it must be screen which presents access to many enhance- replaced with Type AWM 105°C, 18 gauge wire. m
Resumen del contenido incluido en la página 14
Width Beveled Surround Kits Hearth Riser Kits ACCESSORY COMPONENTS These beveled surround panels install around The hearth riser trim kits are designed to be Wall Thermostat the insert body providing an attractive finished used with the optional surround kits (sold look. separately). It provides a finished look below The wall thermostat kit provides temperature the insert face when installed into fireplaces control foroptimum comfort. witha
Resumen del contenido incluido en la página 15
T O O W O L I P O N O L T H N LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliancehas a pilot which must be lightedwith apiezo • Do not use any phonein your building. igniter. When lighting the pilot, follow theseinstructions • Immediately call your gas supplier from a ne
Resumen del contenido incluido en la página 16
T O O W O L I P O N O L T H N INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE. • Appelez immédiatement votre compagnie de gaz en utilisant le télé- A. Cet appareil est muni d’une veilleusequi doit être allumée avecun
Resumen del contenido incluido en la página 17
REPLACEMENT PARTS LIST Gas Controls Item # Part/Cat. No. Description Where Used 1 67L70 Pilot Assembly, NG/LP EBVI5 & EBVI30 67L68 Pilot Tube EBVI5 & EBVI30 3 67L67 Thermocouple EBVI5 & EBVI30 4 60J79 Thermopile (pilot generator) EBVI5 & EBVI30 5a 10K86 Piezo Igniter EBVI5 5b 4M89 Piezo Igniter EBVI30 6 67L87 Electrode Cable (piezo igniter wire w/ electrode) EBVI5 & EBVI30 7a H1657 Gas Valve, NG – SIT EBVI5 7b H6196 Gas Valve, NG – Honeywell EBVI30 Misc. Gas Components 8 H1161 Burner
Resumen del contenido incluido en la página 18
T O O L I P O N O L REPLACEMENT PARTS DIAGRAMS 5a 6 7a 16 7b 5b 15 17 9 10a 10b 18 19 3 3 4 1 1 1a 8 1b 14a 14b 0 13 18 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. I F H F
Resumen del contenido incluido en la página 19
TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1) Spark igniter will not light A. Electrode wire (at piezo igniter) not pushed completely • Check connection pilot after repeated trigge
Resumen del contenido incluido en la página 20
WARRANTY Normally, all parts should be ordered through your Lennox distributor or dealer.Parts will be shipped at prevailing prices attime of order . Your gas appliance is covered by a limited warranty (see warranty certificate provided with appliance). Please read the warranty to be Whenordering repairparts, always givethe following information: familiar with its coverage. 1.The model number of the appliance. Retain this m