Resumen del contenido incluido en la página 1
Heat-N-Glo
Models:
Installers Guide
6000TR
6000XLT-CDN
6000ARCH
6000XLS
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALL-
WARNING: IF THE INFORMATION
ERS GUIDE MUST BE LEFT WITH THE APPLI-
IN THESE INSTRUCTIONS IS NOT
ANCE FOR FUTURE REFERENCE.
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT
WARNING: IMPROPER INSTALLA-
CAUSING PROPERTY DAMAGE,
TION, ADJUSTMENT, ALTERATION,
PERSONAL INJURY, OR DEATH.
SERVICE OR MAINTENANCE CAN
CAUSE IN
Resumen del contenido incluido en la página 2
SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the installation. ! FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty. Prior to the first firing of the fireplace, READ the Using Your Fireplace section of the ! Owners Guide. DO NOT USE this appliance if any part has been under water. Immediately CALL a ! qualified service technician to inspect the unit and to replace any part of the contr
Resumen del contenido incluido en la página 3
Safety and Warning Information ......................... 2 Section 1: Approvals and Codes ...................... 4 Approval Listings and Codes ................................... 4 Appliance Certification ............................................. 4 Installation Codes .................................................... 4 High Altitude Installations .......................................... 4 TABLE Section 2: Getting Started ................................ 5 OF Introducing the Heat-N-Glo Ga
Resumen del contenido incluido en la página 4
Approval Listings Appliance Certification The Heat-N-Glo models discussed in this Installers and Codes Guide have been tested to certification standards and listed by the applicable laboratories. CERTIFICATION MODEL LABORATORY TYPE STANDARD 1 6000TR & Underwriters Vented Gas ANSI Z21.50 CGA2.22/IR#41 6000ARCH Laboratories Fireplace 6000XLT-CDN Underwriters Vented Gas Fireplace ANSI Z21.50 CGA2.22 Approvals Laboratories & Vented Gas ANSI Z21.88 CSA2.33 and Codes Fireplace Heater 6000XLS Underw
Resumen del contenido incluido en la página 5
Heat-N-Glo direct vent gas fireplaces are designed to Introducing the operate with all combustion air siphoned from outside Heat-N-Glo of the building and all exhaust gases expelled to the Gas Fireplaces outside. The information contained in this Installers Guide, unless noted otherwise, applies to all models and gas control systems. Gas fireplace diagrams, including the dimensions, 2 are shown in this section. This gas fireplace and its components are tested Pre-install Getting and safe when in
Resumen del contenido incluido en la página 6
The Heat-N-Glo Warranty will be voided by, and Heat-N-Glo disclaims any responsibility for, the following actions: Installation of any damaged fireplace or vent system component. Modification of the fireplace or direct vent system. Installation other than as instructed by Heat-N-Glo. Improper positioning of the gas logs or the glass door. Installation and/or use of any component part not manufactured and approved by Heat-N-Glo, not withstanding any independent testing laboratory or oth
Resumen del contenido incluido en la página 7
Figure 2. Diagram of the 6000ARCH 7
Resumen del contenido incluido en la página 8
Step 1 The diagram below shows space and clearance requirements for locating a fireplace within a room. Locating the Fireplace 3 Installing the Fireplace MODEL A B C D E 6000TR & 42 22 37 1/8 52 1/2 74 1/4 6000XLS 6000XLT-CDN 42 22 35 1/4 49 3/4 70 3/8 6000ARCH 42* 22 35 1/4 49 3/4 70 3/8 48 1/4** * SURROUND IN FRONT OF FINISHED WALL ** SURROUND FLUSH WITH FINISHED WALL. NOTE: DIMENSIONS SHOWN IN INCHES. Figure 3. Fireplace Dimensions, Locations, and Space Requirements Clearance Requiremen
Resumen del contenido incluido en la página 9
Minimum Clearances from the Vent Pipe to Combustible Materials For Vertical For Horizontal Sections Sections At Wall Firestops Top Bottom Sides Top Bottom Sides 3 inches 1 inch 1 inch 1 inch 2-1/2 inches 1/2 inch 1 inch (75 mm) (25 mm) (25 mm) (25 mm) (63.7 mm) (13 mm) (25 mm) For minimum clearances, see the direct vent termination clearance diagrams on pages 28 and 30 in this manual. Step 2 Fireplace framing can be built before or after the fireplace is set in place. Framing should be positione
Resumen del contenido incluido en la página 10
Step 3 A. Vent System Approvals These models are approved to use D-series direct vent Installing the pipe components and terminations. Approved vent Vent System system components are labeled for identification. NO OTHER VENTING SYSTEMS OR COMPONENTS MAY BE USED. Detailed installation instructions are included with each vent termination kit and should be used in conjunction with this Installers Guide. The drawing below shows vent system components and terminations. The flame and ember appearance
Resumen del contenido incluido en la página 11
DV-45D DV-90D 67/16 65/32 81/2 8/12 11 5/8 11 1/16 73/8 57/8 61/2 51/16 85/8 11 15/16 85/8 DV-48D DV-36D 47 3/4 35 3/4 6-7/16" 6-5/32" (164 mm) (156 mm) 8-1/2" (216 mm) 8-1/2" 11-5/8" 11-1/16" (216 mm) (295 mm) 7-3/8" 5-7/8" (281 mm) 6-1/2" (187 mm) (149 mm) 5-1/16" (165 mm) (129 mm) 8-5/8" (220 mm) 8-5/8" 11-15/16" (220 mm) (303 mm) 47-3/4" (1.2 m) 35-3/4" (908 mm) DV-12D DV-09D DV-06D 11-3/4" 11 3/4 8-3/4" (298 mm) 8 3/4 5-3/4" (222 mm) 5 3/4 (146 mm) NOTE: PIPES OVERLAP 1-3/8 INCHES (
Resumen del contenido incluido en la página 12
STRAIGHT UP VERTICAL VENTING V (FT.) 40' MAX. (12.4 M) NOTE: Model 6000ARCH A 12-inch length of straight vent pipe MUST be the first vent component attached to the unit. Figure 7. Straight Up Vertical Venting 12
Resumen del contenido incluido en la página 13
HORIZONTAL VENTING H Kit No. Max. Run DVK-01D DVK-01TRD 24" (610 mm) NOTE: Models 6000TR and 6000XLS are tested and approved to use 45° elbows in corner installations. However, 90° elbows will result in better performance. Figure 8. Corner Installation 13
Resumen del contenido incluido en la página 14
VENTING WITH ONE (1) 90° ELBOW V (FT.) H (FT.) 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.4m) H = 8' MAX. (2.4m) V+H = 40' MAX. (12.4m) Figure 9. Venting with One 90° Elbow 14
Resumen del contenido incluido en la página 15
FOR 6000TR & 6000XLT-CDN o NOTE: If a 90 elbow is first at- tached to the unit, the maximum horizontal run is 3-feet (914mm). VENTING WITH ONE (1) 90° ELBOW V (FT.) H (FT.) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) H = 20' MAX. (6.2m) V + H = 40 MAX. (12.4mm) NOTE: MODEL 6000ARCH A 12-inch length of straight vent pipe MUST be the first vent component attached to the unit. Figu
Resumen del contenido incluido en la página 16
VENTING WITH TWO (2) 90° ELBOWS V H H + H 1 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1m) 3´ MIN. (914 mm) 6´ MAX. (1.86 m) 15´ MAX. (4.65m) 4´ MIN. (1.22 m) 8´ MAX. (2.48 m) 20´ MAX. (6.2m) V+H+H1 = 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m) H+H = 20´ MAX. (6.2m) 1 Figure 11. Venting with Two 90° Elbows 16
Resumen del contenido incluido en la página 17
o VENTING WITH TWO (2) 90 ELBOWS V (FT.) H + H (FT.) 1 1' MIN. (305mm) 5´ MAX. (1.52m) 2' MIN. (610mm) 10´ MAX. (3.1m) 3' MIN. (914mm) 15´ MAX. (4.65m) 4' MIN. (1.22m) 20´ MAX. (6.2m) V+H+H = 40' MAX.(12.4m) H+H = 20´ MAX. (6.2m) 1 1 NOTE: MODEL 6000ARCH A 12-inch length of straight vent pipe MUST be the first vent component attached to the unit. o VENTING WITH TWO (2) 90 ELBOWS V (FT.) H (FT.) 1' MIN. (305mm) 5´ MAX. (1.52m) 2' MIN. (610mm) 10´ MAX. (3.1m
Resumen del contenido incluido en la página 18
VENTING WITH THREE (3) 90° ELBOWS V H H + H 1 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52 m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX. (3.1 m) 3´ MIN. (914 mm) 6´ MAX. (1.86 m) 15´ MAX. (4.65 m) 4´ MIN. (1.22 m) 8´ MAX. (2.48 m) 20´ MAX. (6.2 m) V1+V+H+H1=40´MAX.(12.4m) H=8´MAX.(2.48m) H+H 1=20´MAX.(6.2m) VENTING WITH THREE (3) 90° ELBOWS V H H + H + H 1 2 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52 m) 2´ MIN. (610 mm) 4´ MAX. (1.22 m) 10´ MAX.
Resumen del contenido incluido en la página 19
VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) NOTE: H + H = 20' MAX. (6.2m) 1 V + V + H + H = 40' MAX. (12.4m) 1 1 VENTING WITH THREE (3) 90° ELBOWS V (FT.) H + H (FT.) 1 1' MIN.(305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) H + H = 20' MAX. (6
Resumen del contenido incluido en la página 20
B. Installing Vent Components For Model 6000TR After determining which set of starting collars will be used (top or rear), follow venting instructions accordingly. Venting Out the Rear Vent Remove the installed rear seal cap from the rear starting collars by cutting the strap at each end. (See Figure 15). Follow the vent configuration tables accordingly. Remove the insulation from the REAR five inch flue. Pull the heat shield out from outside of the firebox. WARNING: THE TOP HEAT SHIELD (INSIDE