Resumen del contenido incluido en la página 2
Safety and Warning Information These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully ! ! described in the Installing the Fireplace section of before starting the installation. FAILURE TO the Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result components MAY BE USED. in a possible fire hazard and will void the warranty. This gas fireplace and vent assembly MUST be Prior to the first firing of the fireplace, READ the !
Resumen del contenido incluido en la página 3
Table of Contents Safety and Warning Information .................................................. 2 Service Parts List ......................................................................... 4 Approvals and Codes .................................................................. 9 Appliance Certification ................................................................................... 9 Installation Codes .....................................................................................
Resumen del contenido incluido en la página 4
Service Parts Pier-HVB-IPI Beginning Manufacturing Date: June 2003 Service Parts Diagram Ending Manufacturing Date: ______ 11 12 14 15 10 16 13 17 9 7 8 Log Assembly 5 6 3 2 4 1 Part number list on following page. 4 Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI • 2006-901 Rev. C • 12/07
Resumen del contenido incluido en la página 5
Service Part List PIER-HVB-IPI IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this Stocked manual may be ordered from an authorized dealer. at Depot ITEM DESCRIPTION SERIAL # PART NUMBER LOGS-MSB Log Set Assembly Y SRV2039-701 1Log 1 N SRV2039-703 2Log 2 N SRV2039-700 3Log 3 N SRV2039-702 4Log 4 N SRV2039-705 5Log 5 N SRV2039-704 6Log 6 N GLA-MS 7 Glass Door Assembly -End
Resumen del contenido incluido en la página 6
ST-HVB-IPI Service Parts Service Parts Diagram Beginning Manufacturing Date: June 2003 Ending Manufacturing Date: ______ 7 8 10 11 12 9 13 Log Assembly 5 6 3 2 4 1 Part number list on following page. 6 Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI • 2006-901 Rev. C • 12/07
Resumen del contenido incluido en la página 7
Service Part List ST-HVB-IPI IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this Stocked manual may be ordered from an authorized dealer. at Depot ITEM DESCRIPTION SERIAL # PART NUMBER LOGS-MSB Log Set Assembly Y SRV2039-701 1Log 1 N SRV2039-703 2Log 2 N SRV2039-700 3Log 3 N SRV2039-702 4Log 4 N SRV2039-705 5Log 5 N SRV2039-704 6Log 6 N 2005-172 7 Non-combustible board N 2
Resumen del contenido incluido en la página 8
PIER-HVB-IPI, ST-HVB-IPI Service Parts Beginning Manufacturing Date: June 2003 Valve Assembly Parts List Ending Manufacturing Date: ______ IPI Valve Assembly 2 3 4 1 5 6 7 8 12 9 10 11 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this Stocked manual may be ordered from an authorized dealer. at Depot ITEM DESCRIPTION SERIAL # PART NUMBER Pilot Assembly NG 385-510A Y 1 Pi
Resumen del contenido incluido en la página 9
Approvals and Codes 1 Appliance Certification High Altitude Installations U.L. Listed gas appliances are tested and approved with- The Heat & Glo fireplace models discussed in this Installers out requiring changes for elevations from 0 to 2,000 feet in Guide have been tested to certification standards and listed the U. S. A. and in Canada. by the applicable laboratories. When installing this appliance at an elevation above 2,000 feet, it may be necessary to decrease the input rating by Certifica
Resumen del contenido incluido en la página 10
Inspection NOTE: The following requirements reference various The state or local gas inspector of the side wall horizontally Massachusetts and national codes not contained in vented gas fueled equipment shall not approve the installa- this document. tion unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with Requirements for the Commonwealth of the provisions of 248 CMR 5.08(2)(a)1 through 4. Massachusetts Exemptions The following equip
Resumen del contenido incluido en la página 11
Getting Started 2 Introducing the Heat & Glo Gas Fireplaces The Heat & Glo Warranty will be voided by, and Heat & Glo disclaims any responsibility for, the following actions: Heat & Glo direct vent gas fireplaces are designed to oper- • Installation of any damaged fireplace or vent system ate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. component. • Modification of the fireplace or direct vent system. The information contained in th
Resumen del contenido incluido en la página 12
5-1/4 (133mm) 1/2 (13mm) (2) 12 (306mm) Ø8 (204mm) 12 42-5/8 Ø8 (305mm) (1082mm) (204mm) ELECTRICAL ACCESS 32-5/16 (820mm) 42 21 (1067mm) 21 (533mm) GAS LINE 34-3/4 (533mm) ACCESS (882mm) 8-1/2 (216mm) 17-15/16 4-1/16 2-5/16 (455mm) (102mm) (58mm) 37-7/16 (950mm) 24 4-3/4 4-1/2 (610mm) (114mm) (121mm) TOP VENT COLLARS TOP STANDOFFS REAR VENT COLLARS SIDE GLASS DOOR GAS CONTROLS & LABELS GAS LINE ACCESS ELECTRICAL ACCESS Figure 1. Diagram of the PIER-HVB-IPI 12 Heat & Glo • PIER-HVB-IPI, ST-HVB
Resumen del contenido incluido en la página 13
5-14 1/2 (133mm) (13mm) (4) 12 (306mm) Ø8 (204mm) Ø8 12 46-5/8 (204mm) (305mm) (1183mm) 42 (1067mm) 32-5/16 ELECTRICAL (820mm) 34-3/4 ACCESS 4-1/2 21 (882mm) (114mm) (533mm) GAS LINE ACCESS 8-1/2 (216mm) 2-5/16 4-1/16 (58mm) 36-3/16 24 (102mm) (919mm) 2-9/16 (610mm) 4-1/2 4-3/4 (64mm) (114mm) (121mm) TOP VENT COLLARS TOP STANDOFFS REAR VENT COLLARS GAS CONTROLS SIDE GLASS & LABELS DOOR GAS LINE ACCESS ELECTRICAL ACCESS Figure 2. Diagram of the ST-HVB-IPI 13 Heat & Glo • PIER-HVB-IPI, ST-HVB-IP
Resumen del contenido incluido en la página 14
Installing the Fireplace 3 Step 1. Locating the Fireplace Note: This location diagram MUST be followed when in- The diagram below shows space and clearance require- stalling a Pier-HVB with a Catalina shelf/marble package since the fireplace is installed further from finished wall. ments for locating a fireplace within a room. FINISHED Note: Refer to Figure 4B for dimensions and appliance WALL locations if installing a Pier-HVB unit with a Catalina shelf and/or marble package. GLASS GLASS PIER
Resumen del contenido incluido en la página 15
Step 2. Framing the Fireplace Minimum Clearances from the Fireplace to Combustible Materials Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommo- date wall coverings and fireplace facing material. The dia- Inches mm gram below shows framing reference dimensions. Glass Sides or Ends .......... 36 .................... 914 CAUTION: MEASURE FIREPLACE DIMENSIONS AND Floor ................................... 0 .......................
Resumen del contenido incluido en la página 16
Shows center of 10” x 12” vent framing holes for top and rear venting. The center of the hole is one inch (25.4mm) above the center of the horizontal vent pipe. E D Framing should be constructed of 2 X 4 lumber or heavier. ST-HV-IPI PIER-HV-IPI B B C A A C Model A B C D E PIER-HVB-IPI 42-1/8 42-1/2 23 35-3/4 48 ST-HVB-IPI 47-5/8 42-1/2 23 35-3/4 48 NOTE: DIMENSIONS SHOWN IN INCHES Figure 5. Framing Dimensions 16 Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI • 2006-901 Rev. C • 12/07
Resumen del contenido incluido en la página 17
DVP90ST 4 6 12 DVP4 DVP6 DVP12 14-1/4 12-3/16 2 MAX. MIN. 24 36 DVP12A 48 9-7/8 DVP24 O 45.0 10-1/4 DVP45 DVP36 11-1/4 7-1/4 1-1/4 TYP DVP48 8-9/16 1/2 TYP 12-9/16 NOTE: PIPES OVERLAP 1-1/4 INCHES AT EACH JOINT. Figure 6. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe) 17 Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI • 2006-901 Rev. C • 12/07
Resumen del contenido incluido en la página 18
Identifying Vent Components Step 3. Installing the Vent System The vent systems installed on this gas fireplace may in- A. Vent System Approvals clude one, two, or three 90° elbow assemblies. The rela- These models are approved to use DVP series direct vent tionships of vertical rise to horizontal run in vent configura- pipe components and terminations (see Figures 6 and 7). tions using 90° elbows MUST BE strictly adhered to. The Approved vent system components are labeled for identifi- rise
Resumen del contenido incluido en la página 19
STRAIGHT UP VERTICAL VENTING V (FT.) BREAK CAP 50' MAX. (15.2 M) HERE NOTE: On vertical venting Figure 10. Flue Restrictor configurations you may want to install the flue re- strictor (385-128). See flue - CHART - 3. Match the amount of restrictor installation in- Vertical Settings vertical in the system structions. 4' 1-1 with the chart to find the 8' 1-2 appropriate position to 15' 2-2 set the Flue Restrictor. 20' 2-3 25' 3-3 30' 4-3 35' 4-4 40' 4-4 50' 4-5 Figure 8 4. Center the Flue Rest
Resumen del contenido incluido en la página 20
NATURAL GAS - VENTING WITH ONE 90° ELBOW V (FT.) H (FT.) 1' MIN. (305mm) 3' MAX. (914mm) 2' MIN. (610mm) 6' MAX. (1.83m) 3' MIN. (914mm) 9' MAX. (2.7m) 4' MIN. (1.22m) 12' MAX. (3.6m) 5’ MIN. (1.5m) 15’ MAX. (4.5m) 6’ MIN. (1.83m) 18’ MAX. (5.5m) V + H = 50’ MAX. (15.2m)(11.3m) PROPANE - VENTING WITH ONE 90° ELBOW V (FT.) H (FT.) 1' MIN. (305mm) 2' MAX. (610mm) V 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' M