Resumen del contenido incluido en la página 1
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
DV36
D I R E C T V E N T F I R E P L A C E
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S MANUAL
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
flame.
• Do not try to light any appliance.
• Do not touch any electrica
Resumen del contenido incluido en la página 2
Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed • To prevent injury, do not allow anyone who is in accordance with their instructions. Carefully read all unfamiliar with the stove to operate it. the instructions in this manual first. Consult the building • To prevent injury, if the pilot or pilot and authority having jurisdiction to determine the need for burn
Resumen del contenido incluido en la página 3
Table of Contents Safety Precautions........................................................................................................2 Table of Contents.........................................................................................................3 Codes And Approvals....................................................................................................4 Specifications...................................................................................................
Resumen del contenido incluido en la página 4
Codes And Approvals DIRECT VENT ONLY: This type is identified by the prefix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed App
Resumen del contenido incluido en la página 5
Specifications INSTALLATION OPTIONS: • Parallel to a wall or placed in a corner • With a floor hearth or raised up the wall • Vertical or horizontal venting WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. DIMENSIONS: � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �
Resumen del contenido incluido en la página 6
Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. PILOT LIGHTING INSTRUCTIONS: H o t w h i l e o p e r a t i n g . D o no t tou c h . S e ver e b ur n s m ay r es u l t. K eep ch i l d r e n , C A U T IO N : c l o t h i n g , f u r n i t u r e, ga s ol i ne o r o the r f l am m a b l e v a p o
Resumen del contenido incluido en la página 7
Operating Instructions PILOT LIGHT: 1. Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints with soapy water. NEVER USE OPEN FLAME FOR LEAK TESTING. 2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several � � � � � � � � � � � � � � � � � � � � � � times
Resumen del contenido incluido en la página 8
Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating BURNER LIGHTING: A) Make sure the pilot is lit. B) Turn gas control knob COUNTER CLOCKWISE to ON. C) Flip the burner switch to ON. D) Turn HI/LO knob to the desired flame height. E) Turn on all electrical power to the unit. NOTE: Check that all burner holes are lit. TO TURN GAS FIREPLACE OFF: � � � � � � � � � � Flip switch to OFF to turn off burners only. � � � � � � � � � � � � � � � �
Resumen del contenido incluido en la página 9
Maintenance And Service ROUTINE MAINTENANCE: At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or no yellow on the tips. Warning: Clearances must be sufficient to allow access for maintenance and service Warning: Failure to position the parts in accordance with this manua
Resumen del contenido incluido en la página 10
Maintenance And Service CLEANING DECORATIVE SURFACES: Painted and porcelain faces should be wiped with a damp cloth periodically. If a plated face has been purchased, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the finish, including cleaners, polish and finger prints. It is important to note that fingerprints and other marks can leave a permanent stain on plated finishes. To avoid this, give the face a quick wipe with denatured alcohol on a soft clot
Resumen del contenido incluido en la página 11
Maintenance And Service BURNER REMOVAL: The burner may need to be removed for a few reasons, including cleaning under the burner, converting the unit to a different gas type, or to replace the burner altogether. Proceed only when the unit has completely cooled down. 1. Remove the fascia or louvers 2. Remove the glass as shown in the MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL. 3. Remove the brick panels as shown in SECONDARY INSTALLATION - OPTIONAL CERAMIC BRICK PANEL INSTALLATION. 4. Re
Resumen del contenido incluido en la página 12
Maintenance And Service Conversion Kit Installation: 1. Turn control knob on the gas valve to the “OFF” position and shut the gas supply off at the shut-off valve upstream of the unit. CAUTION: The gas supply must be shut off prior to disconnecting the electrical power and before proceeding with the conversion. Allow the valve and unit to cool down to room temperature. 2. Remove the glass as shown in the MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL. 3. Carefully remove the log set and ember
Resumen del contenido incluido en la página 13
Maintenance And Service R e d o - r i n g R e d o - r i n g i s v i s i b l e i s n o t vi si b l e g) Re-attach the black protection cap that was removed in step a (Figure 10). L P G C o n f i g u r a t i o n Figure 13: O-ring on valve screw. 8. Reinstall the burner, brick panels, log set, embers, and glass door. Also refer to SECONDARY INSTALLATION - INSTALLING LOG SET AND EMBERS in your Owner’s Manual. When re-installing the burner, ensure that the burner to pilot hood relationship is si
Resumen del contenido incluido en la página 14
� � � � � � � � � � � � Initial Installation QUALIFIED INSTALLERS ONLY INTRODUCTION: This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement, hearths, facing, mantels, and venting terminations will be covered, as well as the gas and electric systems. There are several installation safety guidelines that must be adhered to. Please carefully read the safety precautions at the front of this manual. Warning: Clearances must be sufficient to allow acc
Resumen del contenido incluido en la página 15
Initial Installation QUALIFIED INSTALLERS ONLY FRAMING MOUNT BRACKETS: Mount the two framing mount brackets on each side and secure the fireplace to framing with screws or nails (refer to Figure 16). The brackets will allow for a 1⁄2” (13 mm), 5⁄8” (16 mm), 3⁄4” (19 mm) thick finishing wall. The wall may be finished up to the fireplace facing with combustible material. Figure 16. Nail Tab. CORNER INSTALLATION: The dimensions for installing a fireplace in the corner of a room are given in Fi
Resumen del contenido incluido en la página 16
Initial Installation QUALIFIED INSTALLERS ONLY To Ceiling 37” Even though the DV36 can be installed at floor level without a hearth, there are a few options with raised fireplaces: raised with a floor level hearth (Figures 19), raised with a raised hearth (Figures 20), or raised with no hearth (Figures 21). If the fireplace is raised, it cannot be placed within 37 inches (1.04 m) of the ceiling. When installing a raised fireplace, it is imperative that the support stand is strong enough
Resumen del contenido incluido en la página 17
Initial Installation QUALIFIED INSTALLERS ONLY VENT TERMINATION RESTRICTIONS: N O H D E B C B F i x e d B G C l os e d L F i x e d O pe n a b l e F Cl ose d G O p e na b l e M J K B A I A Te r m i na t i o n C a p A i r S u p p l y I nl e t R e s tr i cti o n Z o n e G G a s M e te r ( T e r m i na t i o n n o t a l l o w e d ) Figure 24. Vent Termination Restrictions, refer to Table 4. Table 4: Vent termination clearances, refer to Figure 24. 1 2 Letter Canadian Installation US Installation De
Resumen del contenido incluido en la página 18
Initial Installation QUALIFIED INSTALLERS ONLY FIREPLACE HORIZONTAL VENT KIT 50-1235: Please read and understand these instructions before installing. Failure to follow these instructions carefully could cause property damage or personal injury. KIT COMPONENTS: Qnty Description Qnty Description 1 Horizontal direct vent termination cap 4 Wire spacers 1 Flue collar adapter 1 4 oz tube Mill-Pac Sealant 1 Wall thimble 1 4 oz tube RTV silicone 9 1 5’ (190 cm) length of Ø4” (10 cm) double walled fle
Resumen del contenido incluido en la página 19
Initial Installation QUALIFIED INSTALLERS ONLY 10. Apply a bead of Mill-Pac Black sealant to the top section of the Ø4” (10 cm) by 5” H o r i z o nt al V e n t T e r m i nati o n (12.5 cm) flue collar adaptor previously installed into the fireplace flue outlet. Slide the Ø4” (10 cm) flex vent over the flue collar and secure with three (3) sheet metal screws evenly spaced. 11. Place a bead of high temperature silicone on the intake collar of the fireplace, slide the Ø65⁄8” (16.25 cm) W
Resumen del contenido incluido en la página 20
Initial Installation QUALIFIED INSTALLERS ONLY EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the Intertek WH listing of the appliance. Table 6: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS). Direct Vent GS Direct-Tem