Resumen del contenido incluido en la página 1
PRACTICAL USER’S GUIDE
FOR THE ELECTRIC FIREPLACE
MODEL NUMBER:
EF3003-230
Quality checked by:
Valued Customer,
We are pleased that you have chosen to purchase an electric
fireplace manufactured by Dimplex North America Ltd.
Over the years, valuable memories will occur around the
warmth and comfort of your hearth. Thank you for allowing our
product to be the backdrop for those special moments.
7206700100REV02
Resumen del contenido incluido en la página 2
CONTENTS PAGE 1 Important Instructions PAGE 2 Model and Serial Number Information PAGE 3 Site selection and preparation PAGE 5 Fireplace Installation PAGE 6 Operation PAGE 9 Maintenance PAGE 12 Warranty
Resumen del contenido incluido en la página 3
QUICK REFERENCE GUIDE FOR THE DIMPLEX ELECTRIC FIREPLACE 1. Prior to the first use of the fireplace verify the following: • Are the circuit breakers for the unit on? • Are the light bulbs in your fireplace loose? (to check, follow the instructions for replacing the light bulbs under the maintenance section of this manual) 2. The heater on your fireplace may emit a slight, harmless odor when first used. This odor is a normal condition caused by the initial heating of internal heater
Resumen del contenido incluido en la página 4
IMPORTANT INSTRUCTIONS SAVE THESE INSTRUCTIONS PLEASE RETAIN THIS USER’S GUIDE FOR FUTURE REFERENCE When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. Read all instructions before using the electric fireplace. 2. This fireplace is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. The trim around the heater outlet becomes hot during heater
Resumen del contenido incluido en la página 5
IMPORTANT INSTRUCTIONS If you have any questions about our products please have the product model and serial numbers available upon calling Dimplex customer service. To locate the model and serial number labels see below. Model Number Serial Number Firebox Carton 2
Resumen del contenido incluido en la página 6
SITE SELECTION AND PREPARATION This section provides easy step by step instructions for selecting a location and preparing the site to install the fireplace into: • Existing Fireplace • New wall construction • Dimplex mantel surround kit or custom made mantel surround NOTE The fireplace insert comes completely assembled and wired. Some tools may be required to prepare the site and assembly/install the trim. The dimensions of the fireplace insert are 762m
Resumen del contenido incluido en la página 7
NOTE A 13 AMP, 230 VOLT (240V in Australia) circuit is required. A dedicated circuit is preferred but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or fuse blows on a regular basis when the heater is operating. Additional appliances on the same circuit 654mm may exceed the current rating of the circuit breaker. 775mm WARNING 305mm To prevent personal injury you should hire a pro
Resumen del contenido incluido en la página 8
WARNING Construction and Electrical Outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electrical shock and injury to persons. MANTEL SURROUND KIT OR CUSTOM MADE MANTEL SURROUND 1. Select a suitable location that is not susceptible to moisture and is away from drapes, furniture and high traffic. 2. Place the fireplace in the desired location to see how it will look in the room. 3. For ease of electrical hoo
Resumen del contenido incluido en la página 9
WARNING Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure that the power cord is stored or secured to avoid tripping or snagging to reduce the risk of fire, electric shock or injury to persons. FIGURE 8 OPERATION This section will explain the function of each convenient control. 1. To access the controls, open the upper grill by pulling, near the top right hand side, forward and down. (FIGURE 9) 2. To loca
Resumen del contenido incluido en la página 10
6 A. MAIN ON/OFF SWITCH The ON/OFF SWITCH supplies power to all fireplace functions (Heater/Flame). B. MAIN POWER INDICATOR LIGHT The main power indicator light will illuminate, confirming the unit is turned ON. C. FLAME ACTION CONTROL Turn the flame action control knob to adjust the flame speed to the desired level. D. FLAME BRIGHTNESS CONTROL Turn the flame brightness control knob to increase or decrease the brightness of the flame and embers. E. LED INDICATORS Indicates the c
Resumen del contenido incluido en la página 11
REMOTE CONTROL USAGE (FIGURE 11) The fireplace is supplied with a radio frequency remote control. This remote control has a range of approximately 25 feet. (17.5m), it does not have to be pointed at the fireplace and can pass through most obstacles (including walls). Remote Control Initialization This procedure is required every time there is a loss of power to the remote control in the fireplace. (i.e. power failure, breaker tripped, main power switch is turned off) 1. Ensure tha
Resumen del contenido incluido en la página 12
8 MAINTENANCE WARNING Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons. LIGHT BULB REPLACEMENT WARNING Allow at least 5 minutes for light bulbs to cool off before touching bulbs to avoid accidental burning of skin. Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log exterior disappears. There are two bulbs under the log set which g
Resumen del contenido incluido en la página 13
9 To replace the bottom light bulbs: 1. lift up the front edge of the log until it clears the front tabs. Pull out until the rear tab clears the back ledge, then lift out. 2. Examine the bulbs to determine which bulbs require replacement. 3. Hold the socket while unscrewing the bulb 4. Hold the socket while screwing in the new bulb. 5. Replace the log by pushing it down and in until it rests against the mirror. LOWER LIGHT BULB REQUIREMENTS Quantity of 4 clear chandelier or c
Resumen del contenido incluido en la página 14
To reassemble lamp area 1. Replace the glass and hold it in place at the top. 2. Fasten retaining clip to hold glass in place. 10 HELPFUL HINTS It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life. Group replacement will reduce the number of times you need to open the unit to replace light bulbs. GLASS CLEANING The glass is cleaned in the factory during the assembly operation. During shipment, installation, handling, etc.,
Resumen del contenido incluido en la página 15
11 WARRANTY Dimplex Electric Fireplaces are tested and inspected prior to shipment and are guaranteed from defect to the purchaser of each new product. Any part which proves to be defective in material or workmanship under normal use within one year will be repaired or replaced without charge.* The Company will not be responsible for any expense incurred for installation, removal for service, or transportation costs. Any such defect should be brought to the attention
Resumen del contenido incluido en la página 16
12