C36EMW
36” Circulating Firebox
Includes: Manual Variable Control Fan System, Combustion
Air Kit and Bi-Fold Doors with Brushed Brass Finish
INSTALLATION INSTRUCTIONS
SAVE THIS BOOK This fireplace is approved for use as a wood burning fireplace or for
This book is valuable. In addition to instructing you on use with a vented gas log approved to ANS Z21.60, Z21.84 or RGA
how to install and maintain your appliance, it a
Resumen del contenido incluido en la página 2
CONTENTS 1. INTRODUCTION ------------------------------------------------------------- PG. 2 2. SELECTING LOCATION ------------------------------------------------------------- PG. 2 3. MINIMUM CLEARANCES ------------------------------------------------------------- PG. 2 4. FRAMING AND INSTALLING ------------------------------------------------------------- PG. 3 5. HEARTH EXTENSION ------------------------------------------------------------- PG
Resumen del contenido incluido en la página 3
FOR YOUR SAFETY WARNING: When processed wood fuel fire logs are used, do not poke or stir the logs while they are • Do not store or use gasoline or any other flammable burning. Use only fire logs that have been evaluated for vapors or liquids in the vicinity of this or any other the application in fireplace and refer to fire log warnings appliance. and caution markings on packaging prior to use. • Due to high temperatures, the appliance should be located out of traffic and away
Resumen del contenido incluido en la página 4
STEP 3: Set the fireplace directly in front of this opening and STEP 5: Before securing fireplace to prepared framing, the slide the unit back until the nailing flanges touch the side ember protector (provided), must be placed between the hearth framing. extension (not supplied), and under the bottom front edge of STEP 4: Check the level of the fireplace and shim with sheet the fireplace to protect against glowing embers falling metal if necessary. Make sure the unit is balanced on each th
Resumen del contenido incluido en la página 5
OUTSIDE AIR KIT (MODEL AK-6) iv. Slide all wiring connections in the electrical housing The installation of an outside air kit should be performed as shown in figure 6b. during the rough framing of the fireplace due to the nature of v. Secure the electrical cover plate with screws its location. Outside combustion air is accessed through the previously removed. mobile home floor (Refer to AK-6 Installation Instructions for vi. Tighten strain relief plastic screw. details). In some instanc
Resumen del contenido incluido en la página 6
ASSEMBLY AND INSTALLATION OF THE DOUBLE An opening large enough to allow the insertion of the firestop WALL CHIMNEY SYSTEM thimble assembly will be required in the ceiling. Attach the Each double wall chimney section is consist of a galvanized firestop/thimble assembly to the ceiling/ceiling joist using outer pipe, a stainless steel inner flue pipe and a wire spacer. screws or staples as shown in figure 8. A minimum of 8 The pipe sections must be assembled independently as the screws or s
Resumen del contenido incluido en la página 7
If the adapter is needed, secure it onto the firestop using holes provided (see figure 10). The row of holes on the sides of the thimble is provided to allow for pitch variances. Position the firestop assembly and thimble to desired angle and secure with screws provided. Insert the thimble and firestop into the All joints (where two pipes are prepared opening and secure to the ceiling by nailing through joined) should be secured with the firestop flanges. The thimble should be ev
Resumen del contenido incluido en la página 8
Note: Storm collar is required but can be installed after the home is sited. PITCH SLOPE OPENING "A" MAX USE FLASHING (degrees) (inches) MODEL NO. FLAT 0 15 V6F-8DM 0 - 6/12 26.6 16 - 1/8 V6F-8DM 6/12 - 12/12 45.0 20 - 3/8 V12F-8DM Figure 16 STORM COLLAR Figure 14 ROOF OPENING CHART TERMINATIONS / SPARK ARRESTOR FLASHING INSTALLATION (V6F-8DM or V12F-8DM) Determine the flashing to be used with the roof open
Resumen del contenido incluido en la página 9
CHASE INSTALLATIONS MANTEL Instructions for chase installations are included with the chase A mantel may be installed if desired (see figure 20), style termination chosen. In a multiple chase installation, be Woodwork such as wood trims, mantels, or any other sure to provide adequate distance between terminations to combustible material projecting from the front face must not prevent smoke spillage from one termination to another. We be placed within 9 inches of the fireplace opening (a
Resumen del contenido incluido en la página 10
Figure 22 GAS LINE ACCESS LOCATION Figure 21 GLASS DOORS IMPORTANT: The glass must be allowed to warm slowly and evenly. The tempered glass will withstand a gradual temperature rise to 550 degrees Fahrenheit, which is more than a normal fire will generate. Such materials as pitch/wax laden logs, very dry mill end lumber, and large amounts of paper or cardboard boxes can create an excessively hot fire and should n
Resumen del contenido incluido en la página 11
STEP 4: Repack insulation around gas line and into sleeve OUTSIDE AIR AND DAMPER HANDLE OPERATION opening. Seal any gaps between gas line and refractory The damper handle, which opens and closes the damper blade, knockout hole with refractory cement or commercial furnace is located in the upper front face of the fireplace. Pushing the cement. Install the gas appliance or cap-off gas line if desired. handle in to the left of the keyway
Resumen del contenido incluido en la página 12
ILLUSTRATED PARTS - 11 - For more information, visit www.desatech.com
Resumen del contenido incluido en la página 13
ILLUSTRATED PARTS ITEM # PART # DESCRIPTION QTY. ITEM # PART # DESCRIPTION QTY. 1 54002 HOMEOWNER'S GUIDE 1 *36 11125 SCREW, #8 x 1/2 6 2 106638-01 PAN, INSULATION 1 *37 11148 SCREW, PHILIP #10 x 5/8 14 3 106639-01 TOP, FIREPLACE 1 *38 11165 SCREW, PHILIP #10 x 5/8 OXIDIZED 14 4 106641-01 SURROUND, FIREPLACE 1 *39 11301 RIVET, 1/8 x 1/8 6 5 106642-01 RETAINER, AIR ROD 1 *40 11318 RIVET, 1/8 x 1/4 OXIDIZED 2 6 106643-01 RETAINER, DAMPER ROD 1 *41 11412 PIN, COTTER 2 *7 90153 OUTSIDE AIR KIT 1 42
Resumen del contenido incluido en la página 14
REPLACEMENT PARTS ACCESSORY PARTS VENT KIT PART NUMBER SEE BELOW VENT KITS - USE FOR MOST COMMON MANUFACTURED (MOBILE) HOME INSTALLATIONS CONTENTS MW8K MW9K 8' vent kit 9' vent kit 36-8DM 36" Double Wall Pipe 22 24-8DM 24" Double Wall Pipe 10 18-8DM 18" Double Wall Pipe 02 FST-A Adjustable Firestop Thimble 11 V6F-8DM Roof Flashing 11 VSC1-8DM Storm Collar 11 RTL-8DM Round Cap Termination 11 - 12-
Resumen del contenido incluido en la página 15
PART NUMBER REFERENCE TABLE* MODEL DESCRIPTION COLEMAN PART # DESA PART # BK3 TRIPLE FAN BLOWER KIT ----- BK3 EP-36 EMBER PROTECTOR 9736-5601 20093 AK-6 OUTSIDE AIR KIT FLOOR INSTALLATION 9736A-2206 90153 AK-6WAI OUTSIDE AIR KIT WALL INSTALLATION 9736-2306 90156 12-8DM DOUBLE WALL PIPE, 12" SECTION 9736A1212 12-8DM 18-8DM DOUBLE WALL PIPE, 18" SECTION 9736A1218 18-8DM 24-8DM DOUBLE WALL PIPE, 24" SECTION 9736A1224 24-8DM 36-8DM DOUBLE WALL PIPE, 36" SECTION 9736A1236 36-8DM 48-8DM