Resumen del contenido incluido en la página 1
Owner's Manual
®
POWER MISERTM 6
ELECTRIC
WATER HEATER
FOR POTABLE WATER HEATING ONLY.
NOT SUITABLE FOR SPACE HEATING.
MODEL NO.
153.326362 30 Gal.
153.326363 30 Gal.
153.326462 40 Ga!.
153.326463 40 Gal.
153.326562 55 Gal.
153.326563 55 Gal.
153.326662 50 GaL Medium
153.326663 50 Gal. Medium
153.326762 40 Gal. Medium
153.326763 40 Gal, Medium
153,326862 50 Gal, Short
......... ; ;;;;_i;:_ii:;:;i:_ii!iiiiii!i_!iiiiiii!iiii!i!ili!!iiii!iiii ¸iiii!iii!i;iiiiiiil ¸iiiiiiiiiiiii!!!;i_iii;iiiiiiiiiii
Resumen del contenido incluido en la página 2
Your safety andthesafety ofothers is extremely important in the installation, use and servicing of this water heater. Many safety=related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others who install, use or service this water heater. to po
Resumen del contenido incluido en la página 3
Read andunderstand instruction improper installation and use may result manual and safety messages in property damage. before installing, operating or servicing thiswater heater. - Do not operate water heater if flood damaged. - Inspect and replace the anode as needed. Failure tofollow instructions and - Install in location with drainage. safety messages could result in - Fill tank with water before operation. death orserious injury. - Be alert for thermal expansion. Instruction manual must rema
Resumen del contenido incluido en la página 4
"q! SAFE INSTALLATION, USEAND SERVICE ........................................................................................................................................ 2 GENERAL SAFETY ............................................................................................................................................................................. 3 TABLE OF CONTENTS ..................................................................................................................
Resumen del contenido incluido en la página 5
The installation must conform with the instructions in this ThankYouforpurchasing a Sears waterheater. Properly manual; electric company rules; and Local Codes, or in the installed andmaintained, it should giveyouyears oftrouble absence of Local Codes, with the current edition of the freeservice. Itisstrongly suggested thatthisnew water heater beprofessionally installed, contact thelocalSearsService NEC - National Electrical Code, NFPA 70. This publication is available from your local government
Resumen del contenido incluido en la página 6
Materials Needed To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materials, depending on your type of installation. DRAIN PANS AVAILABLE IN 20" EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS AVAILABLE IN 2 DIAMETER FORWATER HEATERS HAVING A DIAMETER 18" OR LESS, GALLONS , AND 5 GALLONS CAPACITY THROUGH LOCAL SEARS STORE OR 24" DIAMETER FOR WATER SERVICE CENTER. HEATERS HAVING A DIAMETER 22" WATER HEATER INSTALLATION KIT
Resumen del contenido incluido en la página 7
The water passing out of the drain valve may be extremely hot. Removing the Old Water Heater To avoid being scalded, make sure all connections are tight and that the water flow is directed away from any person. 4. Check again to make sure the electrical supply is turned "OFF" to the water heater. Then unplug the water heater (cord set) or disconnect the electrical supply connection from the water heater junction box. FIGURE 4. 5a. If you have copper piping to the water heater, the two copper wat
Resumen del contenido incluido en la página 8
• Sensors mounted in the drain pan that turn offthe water supply to the entire home when water is detected in the drain pan. • Water supply shut-off devices that activate based on the water Mineral Buildup or Sediment IVlayAccumalate pressure differential between the cold water and hot water pipes connected to the water heater. . This causes the water heater to become much heavier than normal. ® If spilled, could cause staining. Installations in Residential Garages Mineral buildup or sediment ma
Resumen del contenido incluido en la página 9
HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Fire Hazard / Electric Shock Hazard Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water - Do not use this water heater with in you
Resumen del contenido incluido en la página 10
Fit T & P valve insulation over valve. Make sure that the insulation NOTE: Toprotect against untimely corrosion ofhot and cold does not interfere with the lever of the T & P valve. water fittings, it is strongly recommended that di=electric unions or couplings be installed on this water heater when Secure all insulation using tape. connected to copper pipe. 1. Look at the top cover of the water heater. The hot water outlet is marked hot. Put two or three turns of teflon tape around the threaded
Resumen del contenido incluido en la página 11
Position thevalvedownward andprovide tubing sothatany Ifaftermanually operating thevalve, itfailstocompletely reset discharge willexitonlywithin 6inches (153mm)above, orat andcontinues to release water, immediately closethecold any distance below thestructural floor. Becertain thatnocontact water inlet tothewater heater, follow thedraining instructions, ismade withanyliveelectrical part.Thedischarge opening andreplace thetemperature-pressure reliefvalve witha new one. must not be blockedor reduc
Resumen del contenido incluido en la página 12
Necessary element conversion parts are located in a small Converting the Lower Element bag contained within the electrical junction box on top of the water heater. These instructions only cover the conversion of the convertible element, read this entire manual before attempting to install or operate the water heater. The water heater is factory set to CONVERSION PARTS operate at 3800 watts. The lower element can be converted to operate at 5500 watts. Refer to "Facts to Consider About the Convert
Resumen del contenido incluido en la página 13
8. Tighten terminals 2 and3 to ensure proper electrical LIFT OUT TABTO UNCLIPTERMINAL connection. JACK_ _-, COVER FROM PLASTIC TABSON THERMOSTAT TERMINAL COVER t BOTH SIDES OF TERMINAL COVER CLIPPED TO _ THERMOSTAT AT HOL IT IN PLACE THIS POINT _ tHERMOSTAT BRACKET Fire and E×plosion Hazard _-TANK • Failure to tighten screws can _'_ " ELEMENT cause a fire. THERMOSTAT • Failure to do this could result in death, serious bodily injury, or property damage. FIGURE 16. Failure to tighten terminal scre
Resumen del contenido incluido en la página 14
11.Replace theaccess panel. Fire Hazard / Electric Shock Hazard ® Do not use this water heater with any voltage other than shown on the model rating plate. Failure to use the correct voltage shown on the model rating plate FIGURE 21. could result in death, serious bodily injury, or property damage. 12. Complete wiring to the water heater, or if completed, turn "ON" electric power to the water heater after filling the tank with water. If wiring from your fuse box or circuit breaker box was alumin
Resumen del contenido incluido en la página 15
5. Wiring Diagrams (see "Wiring Diagrams" section) have been 6. Use wire nuts and connect the power supply wiring to the supplied showing the two most common types of wires inside the water heater's junction box. connections between the water heater and the power supply. You can easily see which type connection you have by 7. The water heater must be electrically "grounded" by the removing the junction box cover on top of the water heater. installer. A green ground screw has been provided on the
Resumen del contenido incluido en la página 16
Wiring Diagrams STANDARD WiriNG FOR 2 WiRE LEAD WATER HEATERS NON=SIMULTANEOUS OPERATION 240 VOLT DOUBLE ELEMENT A6 [ GROUNDTERMINAL--""""-_,_ * Before removing any access panels or servicing the water _1 _*,_l L_ POWER SUPPLY heater, make sure the electrical supply to the water heater is H,-TEMP _ JUNJTiON turned "OFF". LIMIT_l O_1I_(bl BOX sw,TCB _40-11_ tt" , Failure to do this could result in death, serious bodily injury, or TH2tggPTAT --n property damage. J I_ _f% ELEMENT <, THERMOS FOR 550
Resumen del contenido incluido en la página 17
The lower thermostat is factory set at a position which Temperature Regulation approximates 120°F (49°C), and is adjustable if a different water temperature is desired. Read all warnings in this manual and on the water heating before proceeding. Water temperature over 125°F (52°C) can cause severe burns TEMPERATURE instantly resulting in severe injury ADJUSTMENT or death. KNOB Children, the elderly, and the physically or mentally disabled are at highest risk for scald injury. Feel water before b
Resumen del contenido incluido en la página 18
Theupper andlower thermostats areadjustable ifa different Temperature-Pressure Relief Valve Operation watertemperature is desired.Readall warningsin the "Temperature-Regulation" section before proceeding. The temperature-pressure relief valve must be manually operated at least once a year. 1. Turn "OFF" the electric power to the water heater at the junction box. • Burn hazard [ • Hotwater discharge. Before removing any access • Keep clear of relief valve panels or servicing the water discharge o
Resumen del contenido incluido en la página 19
Thewater heater should bedrained ifbeing shutdown during 1. Turn "OFF" the electrical power to the water heater at the freezing temperatures. Also,periodic draining andcleaning of junction box. sediment fromthetankmaybenecessary. 2. Remove the access panel and the insulation cap with handle. l 3. Lift out the tab as shown below to unclip the terminal cover • Before removing any access from the thermostat. The terminal cover can now be removed panels or servicing the water from the thermostat. he
Resumen del contenido incluido en la página 20
Remove the two screws securing the access panel, and remove panel. [ o Before removing any access panels or servicing the water heater, make sure the electrical supply to the water heater is turned "OFF". • Failure to do this could result in death, serious bodily injury, or property damage. FIGURE 33. Before beginning turn "OFF" the electric power supply to the water heater. 5. Remove the insulation cap with handle. QI .___J FIGURE 30. 2. Turn off the water supply to the water heater at the wate