Resumen del contenido incluido en la página 1
™
BELLA OWNER'S MANUAL
Resumen del contenido incluido en la página 2
CONTENTS INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 MOUNTING RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 FAN INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 CONTROL FEATURES: VERSA•TOUCH OPERATION
Resumen del contenido incluido en la página 3
MOUNTING RECOMMENDATIONS Before mounting your Casablanca fan, read the following helpful recommendations. The location of the fan, air circulation, and fan size are all important factors to consider before installation. Location Ceiling fans have practical uses in almost every room in your home. We suggest you follow these mount- ing recommendations as you decide where to install your Casablanca fan. • For safety reasons, the fan blades must be a minimum of 7′ above the floor. • Do not locate th
Resumen del contenido incluido en la página 4
™ BELLA INSTALLATION INSTRUCTIONS Unpacking: Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check them against the parts listed here. Before discarding packaging material, be certain that all parts have been removed. WORK BENCH SETUP Setup. Remove the bottom foam from the box NOTE: The fan weight is 30 pounds. and place the fan rightside up in the foam. This protects the lamp socket during assembly. NOTE: If this is the second Versa•Touch fan i
Resumen del contenido incluido en la página 5
INSTALL INCANDESCENT BULBS Step E. Install the four 40 watt incandescent light bulbs. INCANDESCENT LIGHT BULBS (4) CEILING HARDWARE ADDITIONAL HARDWARE 1 2 / ″ x 8-32 ROUND HEAD 4 SCREWS (2) CROSSBAR WIRE NUT (4) 1″ x 8-32 ROUND MOUNTING FLAT WASHER (2) HEAD SCREWS (2) BRACKET GETTING STARTED Installing a New Ceiling Fixture Outlet Box Using Existing Ceiling Fixture Outlet Box If you do not have an existing fixture located where you wish After turning the power OFF at its source (either circuit
Resumen del contenido incluido en la página 6
™ BELLA CANOPY INSTALLATION Step 2. Attach the canopy to the crossbar mount- 1 ing bracket with three of the 8-32 x 2 /4″ long CROSSBAR MOUNTING canopy screws and canopy lock washers. BRACKET INSTALLED Tighten the screw firmly by hand only. Note: On sloped ceilings, align the canopy opening towards the top or CANOPY room peak. CANOPY LOCK WASHERS CANOPY SCREWS HANGING THE FAN Step 3. To hang the fan body in the canopy, hold the fan body firmly and in- sert the ball into the canopy opening. Check
Resumen del contenido incluido en la página 7
CANOPY HATCH INSTALLATION Step 5. Tuck the wires into the canopy with the wire nuts pointed upwards, so that the WHITE and BLACK wires are on opposite sides of the canopy and all wires are clear of the canopy opening. Step 6. Install canopy hatch with the last TILT THE CANOPY canopy screw and lock washer. To do this, FAN TO HATCH tilt the fan body away from the hatch INSTALL LAST opening. CANOPY Tighten the screws firmly by hand only, LOCK SCREW WASHER Step 7. Straighten the fan, then check to
Resumen del contenido incluido en la página 8
™ BELLA INSTALL BLADES Step 10. Using the blade holder screws from the pack, attach each blade/blade holder as- sembly to the motor (two screws per blade). Use the blade access hole to install the screws. Using the screwdriver, tighten securely by hand only. BLADE HOLDER SCREW BLADE ACCESS PLATE INSTALLATION Step 11. Using the two screws removed in Step 9, reinstall the blade access plate to the fan as shown. Using the screwdriver tighten securely by hand only. INSTALL HALOGEN BULB AND GLASS St
Resumen del contenido incluido en la página 9
R VERSA•TOUCH INSTALLATION W-42 W-43 CONTROL DRYWALL WOOD SCREW SCREW W-43 HOLDER 3 /8” ANCHOR SCREW 6-32 X 6-32 X 1” CONTROL 9V BATTERY 6-32 (2) 1” (2) (2) (2) VERSA•TOUCH CONTROL HOLDER INSTALLATION CAUTION! DO NOT USE WITH WALL DIMMER. REMOVE TABS ROCKER STANDARD TYPE OUTER TOGGLE LIGHT MOUNTING INNER SWITCH SWITCH HOLES MOUNTING HOLES SWITCH SWITCH COVER COVER PLATE PLATE CONTROL Rocker Light Switch HOLDER Standard Light Switch Step 1. Break off the two tabs by pushing outward. Step 1. R
Resumen del contenido incluido en la página 10
VERSA•TOUCH OPERATION SEND SIGNAL Fan Control LED To start the fan. Press the selected speed button to run the fan at the desired speed. LO=Low speed MED=Medium speed HI=High speed To turn off the fan. Press the FAN OFF button. Airflow Direction To reverse the airflow press the REVERSE button. Reverse operates at any speed whether fan is on or off. The fan returns to its set speed after reversing. Light Control Turn the light on or off independently from the fan by pressing the UP LIGHT,
Resumen del contenido incluido en la página 11
TROUBLESHOOTING Before Requesting Service: Please follow this troubleshooting guide before contacting your dealer for assistance. Caring for Finishes: For cleaning, a soft brush or lint-free cloth Never Lubricate this Fan! should be used to prevent scratching the finish. A vacuum cleaner The precision motor at the heart of your Casablanca fan features brush nozzle can remove heavier dust. Surface smudges or an accu- sealed bearings that are lubricated for life. Do not attempt to oil mulation of
Resumen del contenido incluido en la página 12
761 CORPORATE CENTER DRIVE • POMONA, CA 91768 TOLL FREE: 888-CASA-1ST (227-2178) www.CasablancaFanCo.com ©COPYRIGHT 2001 CASABLANCA FAN COMPANY • U.S. PATENT PENDING PRINTED IN ROC