Resumen del contenido incluido en la página 1
Micathermic
Heater Instruction Booklet
KMH100
KMH100_IB_A11_FA.indd 1 14/09/11 1:58 PM
Resumen del contenido incluido en la página 2
Important Please retain your instruction book for future use. In the event that you need some assistance with your Kambrook appliance, please contact our Customer Service Department on 1300 139 798 (Australia) or 0800 273 845 (New Zealand). Alternatively, visit us on our website at www.kambrook.com.au or www.kambrook.co.nz KMH100_IB_A11_FA.indd 2 14/09/11 1:58 PM
Resumen del contenido incluido en la página 3
Contents Kambrook Recommends p4 Safety First Your Kambrook p6 Micathermic Heater Quick Start Guide p7 Using Your p8 Micathermic Heater Care, Cleaning and Storage p13 KMH100_IB_A11_FA.indd 3 14/09/11 1:58 PM
Resumen del contenido incluido en la página 4
Kambrook Recommends Safety First IMPORTANT: Please retain your instruction book for future use. At Kambrook, we believe that safe performance is the first priority in any consumer product, so that you, our valued customer can confidently use and trust our products. We ask that any electrical appliance that you use be operated in a sensible fashion with due care and attention placed on the following important operating instructions. Important Safeguards For Your Kambrook Micathermic Heater
Resumen del contenido incluido en la página 5
• Do not allow materials that have been in • Use this heater only as described in this contact with oil, petroleum based products instruction manual. Any other use not or drying fluids to come in contact with the recommended by the manufacturer may heater. cause fire electric shock or injury and voids all warranties. • Do not run the cord under carpeting or cover the cord with rugs, runners or the like. Arrange • Keep combustible materials such as drapes the cord away from traffic areas an
Resumen del contenido incluido en la página 6
Your Kambrook Micathermic Heater 1. 1500 watts of power for fast and 5. Wheels for easy movement even heat 6. Carry handle 2. Heat setting dial for OFF, LOW NOT SHOWN or HI • Wall mountable bracket 3. Variable THERMOSTAT control to maintain your • Safety tip-over switch desired temperature • ThermoGuard safety protection 4. Micathermic element for peace of mind produces both radiant and convection heat 6 KMH100_IB_A11_FA.indd 6 14/09/11 1:58 PM
Resumen del contenido incluido en la página 7
Quick Start Guide Turning the Setting the Setting the heater on after variable heating mode assembly temperature Turn the heat Plug the cord into Turn the heat Turn the variable setting dial to the a 230V or 240V setting dial in a THERMOSTAT dial in off position. Make power point and clockwise position an anti-clockwise sure that the switch switch on. to the LOW or HI position to the on the THERMOSTAT heat setting. MAX setting. dial is set to MIN. Turning the heater off When a Return th
Resumen del contenido incluido en la página 8
Using Your Micathermic Heater 2. Line up the screw in the wheels Before First Use with those in the base of the Remove any promotional material or brackets, and secure. packaging from the heater. When unpacking the heater, check to see you have received the wheels and wall mounting packs, before discarding the packaging. Unwind the cord to its full length and place the heater on a firm, level surface in a stable upright position. Visually inspect the air inlet and outlets to ensure th
Resumen del contenido incluido en la página 9
4. Line up the bracket screw with CAUTION: Before the screw hole in the base of the mounting the heater to heater, and secure. the wall, please ensure that both attachment points are secure in either timber or concrete. Do NOT secure directly into plaster. Please contact a tradesman if you are unsure. Please see Fig. 7. which illustrates the points of contact. Ensure Fig. 5 that the heater is at least 0.5 metres from the floor and corners of the wall. NOTE: Ensure the feet are r
Resumen del contenido incluido en la página 10
Using Your Micathermic Heater continued 2. As a general safety guide select 6. Once the heater is mounted a suitable location to wall mount on the wall, lodge the heater the heater, approximately 0.5m to the mounting bracket to from any furniture/furnishing either prevent the heater from being side of the unit and 2m from any accidently dislodged from the furniture/furnishing placed in front mounting bracket. of the heater. The heater must be 7. Visually inspect the front panel mounted
Resumen del contenido incluido en la página 11
Setting The Heating Mode Setting The Variable Thermostat The variable THERMOSTAT can be used to maintain your desired temperature. Turn the variable THERMOSTAT dial to the MAX setting. Once a comfortable room temperature has been reached, slowly turn the variable THERMOSTAT dial anti-clockwise until a click sound is heard. Fig. 9 At this setting your heater will automatically cycle on and off to maintain the desired room To activate the heater, turn the heat temperature. setting dial
Resumen del contenido incluido en la página 12
Using Your Micathermic Heater continued ThermoGuard Overheating Safety Device Your heater is fitted with a safety device that switches off the heater in the event of overheating. Should this heater stop working, turn off the heater and inspect the air inlet and outlet for blockages. Wait at least five minutes for the protection system to reset before attempting to restart the heater. If the heater fails to operate or the safety device switches off again, return the heater to your nea
Resumen del contenido incluido en la página 13
Care, Cleaning and Storage Ensure that the heater is switched off and disconnected from the power point before cleaning. Use a clean, dry cloth to clean the external surfaces of the heater. If the heater has collected dust or dirt inside the unit, have the unit cleaned by a qualified service agent. Do not operate the heater in this condition. Do not attempt to open up any parts of the heater as there are no customer serviceable parts inside. When not in use, store the heater (preferabl
Resumen del contenido incluido en la página 14
Notes 14 KMH100_IB_A11_FA.indd 14 14/09/11 1:58 PM
Resumen del contenido incluido en la página 15
Notes 15 KMH100_IB_A11_FA.indd 15 14/09/11 1:58 PM
Resumen del contenido incluido en la página 16
Kambrook - Australia Kambrook - New Zealand Building 2, Port Air Industrial Estate Private Bag 94411 1A Hale Street Botany, Manukau Botany NSW 2019 Auckland 2163 Australia New Zealand Customer Service Line 1300 139 798 Customer Service Line/ Customer Service Fax 1800 621 337 Spare Parts 0800 273 845 Customer Service Fax 0800 288 513 www.kambrook.com.au www.kambrook.co.nz Due to continual improvement in design or otherwise, the product you purchase may differ slightly from the illustration in t