Resumen del contenido incluido en la página 1
VENTED DECORATIVE GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
MODELS BQMV18N, BQMV18P,
BQMV24N AND BQMV24P
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switc
Resumen del contenido incluido en la página 2
WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer, service agency or the gas supplier. WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built fireplace, constructed of noncombustible material and connected to a working flue. (See pa
Resumen del contenido incluido en la página 3
SAFETY INFORMATION WARNING: Do not use a blow- er insert, heat exchanger insert or WARNING: This product con- other accessory not approved for tains and/or generates chemicals use with this appliance. known to the State of California to cause cancer or birth defects WARNING: This appliance or other reproductive harm. is equipped for (natural or pro- pane/LP) gas. Field conversion WARNING: Keep flue open is not permitted. when operating unit. WARNING: Do not allow fans IMPORTANT: Rea
Resumen del contenido incluido en la página 4
9. Do not use a blower insert, heat exchanger SAFETY INFORMATION insert or other accessory not approved for use Continued with this log set. 10. The installation and provisions for combustion Keep the appliance area clear and ventilation air must conform with the Na- and free from combustible ma- tional Fuel Gas Codes, ANSI Z233.1/NFPA 54, terials, gasoline and other flam- Section 5.3, Air for combustion and Ventilation. mable vapors and liquids. 11. Do not run heater • where flammable liquid
Resumen del contenido incluido en la página 5
PRODUCT INSTALLATION IDENTIFICATION WARNING: A qualified ser- vice person must install heater. WARNING: Failure to posi- Follow all local codes. tion the parts in accordance with these diagrams or failure WARNING: Before installing to use only parts specifically in a solid fuel burning fireplace, approved with this appliance the chimney flue and firebox may result in property damage must be cleaned of soot, creo- or personal injury. sote, ashes and loose paint by a qualified chimney clean
Resumen del contenido incluido en la página 6
drawing it up the chimney. If the smoke spills out INSTALLATION into the room, extinguish the flame and remove any Continued obstruction until proper venting is achieved. CHECK GAS TYPE The chimney flue damper must be fixed open to pro- Use the correct gas type (natural or propane/LP) for vide a minimum of 32 square inch of free air opening your unit. If your gas supply is not correct, do not at all times during operation of the log set. A damper instal in fireplace. Call dealer where you bou
Resumen del contenido incluido en la página 7
INSTALLATION CAUTION: Never connect Continued propane/LP unit directly to the INSTALLING APPLIANCE propane/LP supply. This unit re- quires an external regulator (not WARNING: Special care is supplied). Install the external required if you are installing the regulator between the unit and unit into a sunken fireplace. You the propane/LP supply. must raise the fireplace floor to allow access to gas log controls. This will insure adequate air WARNING: Never connect flow and guard against
Resumen del contenido incluido en la página 8
Locate sediment trap where trapped matter is not INSTALLATION likely to freeze. A sediment trap traps moisture and Continued contaminants. This keeps them from going into heater controls. If sediment trap is not installed or CAUTION: Use only new, black is installed wrong, heater may not run properly. iron or steel pipe. Internally-tinned copper tubing may be used in CAUTION: Avoid damage to certain areas. Check your local gas control. Hold gas control codes. Use pipe of 1/2" diamet
Resumen del contenido incluido en la página 9
Pressure Testing Appliance Gas INSTALLATION Connections Continued 1. Open equipment shutoff valve (see Figure 8). 6. Reconnect heater and equipment shutoff 2. Open main gas valve located on or near gas valve to gas supply. Check reconnected fit- meter for natural gas or open propane/LP tings for leaks. supply tank valve. Test Pressures Equal To or Less Than 3. Make sure control knob of appliance is in the 1/2 PSIG (3.5 kPa) OFF position. 1. Close equipment shutoff valve (see Figure 8). eck
Resumen del contenido incluido en la página 10
5. Wait five (5) minutes to clear out any gas. OPERATING APPLIANCE If you then smell gas, STOP! Follow "B" in FOR YOUR SAFETY the safety information in column 1. If you READ BEFORE LIGHTING don't smell gas, go on the next step. 6. Press in and turn control knob counter- clockwise to the PILOT position. WARNING: Keep flue open Press in control knob for five (5) seconds when operating unit. (see Figure 12). 7. With control knob pressed in, press and release WARNING: If you do not fol- ign
Resumen del contenido incluido en la página 11
To Unlock press both buttons tog ether on hand- OPERATING APPLIANCE held remote control until the light stops flashing. Continued The hand-held remote is now unlocked. NOTICE: You must light the pilot INSPECTING BURNERS before using the hand-held re- Check pilot flame pattern and burner flame pat- mote control unit. See Lighting terns often. Instructions on page 10. PILOT FLAME PATTERN You can view the pilot light through the pilot After lighting, let pilot flame burn for about viewing hole on t
Resumen del contenido incluido en la página 12
• Keep area around log set clean and clear of INSPECTING BURNERS debris. Continued • Periodically inspect the air mixer and burner If burner flame pattern is incorrect, as shown in tube for foreign matter blocking the air inlet Figure 18. and flame holes. • turn appliance off (see To Turn Off Gas to Ap- • Once every year a qualified agency or certified pliance, page 10) chimney sweep should examine and clean the • see Troubleshooting, page 13 venting system of the fireplace. Dark Orange SERVIC
Resumen del contenido incluido en la página 13
TROUBLESHOOTING WARNING: Turn off appliance and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed, 1. Ignitor electrode not con- 1. Reconnect ignitor cable there is no spark at ODS/pilot nected to ignitor cable 2.
Resumen del contenido incluido en la página 14
TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY ODS/pilot lights but flame goes 1. Control knob not fully 1. Press in control knob fully out when control knob is re- pressed in leased 2. Control knob not pressed in 2. After ODS/pilot lights, keep long enough control knob pressed in for 30 seconds 3. Safety interlock system has 3. Wait one minute for safety in- been triggered terlock system to reset. Repeat ignition operation 4. Equipment shutoff valve not 4. Fully open equipme
Resumen del contenido incluido en la página 15
TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Dark orange flame in burner dur- 1. Not enough air 1. Check burner(s) for dirt ing burner combustion and debris. If found, clean burner(s) (see Cleaning and Maintenance, page 12) 2. Gas regulator defective 2. Replace gas regulator Slight smoke or odor during initial 1. Residues from manufacturing 1. Problem will stop after a few operation processes and log curing hours of operation Produces a whistling noise when 1. Turning cont
Resumen del contenido incluido en la página 16
TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating appliance where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, c
Resumen del contenido incluido en la página 17
SPECIFICATIONS This appliance has been design certified to ANSI ZZ1.60-2003 and CSA 2.26-2003 Decorative Gas Appliances for Installation in Solid Fuel Burning Fireplaces by OMNI Test Laboratories. BQMV18N BQMV18P BQMV24N BQMV24P Btu (Variable) 36,000/53,000 35,000/45,000 36,000/53,000 35,000/45,000 Type Gas Natural Gas Only Propane/LP Only Natural Gas Only Propane/LP Only Ignition Piezo Piezo Piezo Piezo Manifold Pressure 3.5" W.C. 10" W.C. 3.5" W.C. 10" W.C. Inlet Gas Pressure (in. of w
Resumen del contenido incluido en la página 18
ILLUSTRATED PARTS BREAKDOWN MODELS BQMV24N, BQMV24P, BQMV18N AND BQMV18P 17 16 15 7 1 9 8 6 13 5 10 3 14 12 2 4 1 1 18 www.desatech.com 117423-01A
Resumen del contenido incluido en la página 19
PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 12 of this manual. KEY PART NUMBER NO. BQMV24N BQMV24P BQMV18N BQMV18P DESCRIPTION QTY. 1 111793-01 111793-01 111808-02 111808-02 Grate 1 2 111817-02 111817-02 111817-02 111817-02 Flexible Tube 1 3 099998-01 099998-01 099998-01 099998-01 Fan Switch 1 4 103784-02 103784-02 103784-02 103784-02 Knob Extension (HI/LOW) 1 5 103784-01 103784-01 10378
Resumen del contenido incluido en la página 20
WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY VENTED GAS LOG APPLIANCES DESA warrants this product to be free from defects in materials and components for four (4) years from the date of