Resumen del contenido incluido en la página 1
W
A
R
R
DIGITAL
PROGRAMMABLE
9610
® THERMOSTAT
™
INTEGRATED COMFORT SOLUTIONS
G
E
ELECTRIC GAS
7 Day Programmable
1 Heat / 1 Cool
User’s Manual
Quick Start
Installation and
Programming
110-655B
As an Energy Star partner, Maple Chase has
determined that this thermostat product meets
the Energy Star guide lines for energy efficiency.
Installation Guide
IMPORTANT SAFETY INFORMATION WARNING:
Always turn off power at the main power source by unscrewing
•
fuse or switching circuit breaker to th
Resumen del contenido incluido en la página 2
Features • Four pre-programmed Energy Star setpoints for each day of the week. • Two “AA” ENERGIZER brand batteries retain program memory, even during power outages. • Low battery indicator. • Fahrenheit/Celsius display option. • Programmable from 45°F (7°C) to 90°F (32°C). • Accuracy within ± 1 degree. • Adjustable temperature differential: 1-3 degrees. • Maintains summer and winter programming. • Low temperature freeze protection. While in heat mode, thermostat will mechanically turn on heat i
Resumen del contenido incluido en la página 3
> Figure 1 Installing Item 9610 Thermostat NOTE: FOR NEW INSTALLATIONS, MOUNT THERMOSTAT ON INSIDE WALL, 4-5 FEET ABOVE THE FLOOR. DO NOT INSTALL BEHIND A DOOR, IN A CORNER, NEAR AIR VENTS, IN DIRECT SUNLIGHT, OR NEAR ANY HEAT OR STEAM GENERATING FIXTURES. INSTALLATION AT THESE PLACES WILL AFFECT THERMOSTAT OPERA- TION. 1. Turn power off to the heating and cooling systems. 2. Place COOL/OFF/HEAT In OFF position. COOL-OFF-HEAT PROG MAN SET PROG/MAN COOL-OFF-HEAT AUTO - ON AUTO - ON 3.Place AUTO-O
Resumen del contenido incluido en la página 4
Figure 3 MOUNTING HOLES 7. Drill the marked holes using a 3/16” drill bit. 8. Tap plastic anchors into the holes. 9. Align base with plastic anchors and feed wires through opening. See Fig 4. Figure 4 10. Secure base to wall with supplied screws. 11. Connect wires to terminal strip. Refer to wiring diagrams on other side of this sheet. Make sure wire connections are secure. 12. Place fan option switch into either the “ELEC” or “GAS” position depending upon the type of furnace. Refer to Figure 5.
Resumen del contenido incluido en la página 5
> > > 14. Install two “AA” ENERGIZER brand batteries or equivalent into bat- tery compartment. Be sure to place positive (+) ends of batteries toward (+) battery terminals in the battery compartment. The display will show as follows: 15. Replace cover onto thermostat by snapping into place. 16. Turn on power to system . Test thermostat as described in the following section. Programming Guide Set Time of Day, Day of Week, Temperature Differential, Residual Cooling 1. Press & Hold SET. Press PROG
Resumen del contenido incluido en la página 6
> > > > 3. Press Press SET P To change Temperature Differential* *THE TEMPERATURE DIFFERENTIAL IS FACTORY PRESET AT 1°. THIS MEANS THAT WHENEVER THE ROOM TEMPERATURE CHANGES BY ONE FULL DEGREE FROM THE TEMPERATURE SETTING, THE SYSTEM WILL TURN ON. IF THE SYSTEM TURNS ON TOO OFTEN, INCREASE THE TEMPERATURE DIFFERENTIAL. 4. Press Press SET P To change Residual Cooling** **THE RESIDUAL COOL FEATURE WILL KEEP THE SYSTEM FAN ON FOR AN ADDITIONAL 30, 60 OR 90 SECONDS AFTER THE COMPRESSOR CYCLES OFF. R
Resumen del contenido incluido en la página 7
> > > > > Setting Daily Programming Summer (Cool) Settings: 1. Place COOL-OFF-HEAT COOL-OFF-HEAT in COOL position. PROG MAN SET PROG/MAN COOL-OFF-HEAT AUTO - ON SET PR 2. Press SET button. The display will show a number from 1 to 7. This number represents the day of the week to be programmed If pro- gramming individual days, press either✞ or✟ button to adjust the day of the week to program. 3. Press SET. Press✞ or✟ to change MORN time 4. Press SET. SET PR PROG MAN SET PROG/MAN COOL-OFF-HEAT AUT
Resumen del contenido incluido en la página 8
> > > > > 3. Press PROG/MAN button ET PROG/MAN until indicator is in PROG position. PROG MAN SET PROG/MAN COOL-OFF-HEAT AUTO - ON PROG MAN NOTE: WHILE IN THE COOL MODE, (OR HEAT AND COOL FOR SINGLE STAGE HEAT PUMP SYSTEM) ONCE THE THERMOSTAT TURNS THE SYSTEM OFF, A BUILT-IN DELAY KEEPS THE COMPRESSOR FROM TURNING ON FOR ABOUT 5 MINUTES. THIS PRO- TECTS THE COMPRESSOR. NO ADDITIONAL TIME DELAY RELAY (DELAY ON BREAK) IS NECESSARY. TOP OVERRIDE THE 5-MINUTE DELAY FOR INSTALLATION, PRESS RESET. THIS
Resumen del contenido incluido en la página 9
To Test Thermostat WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS VALVE OR SYS- TEM CONTROL TO TEST OPERATION. THIS WILL DAMAGE THE THERMOSTAT AND VOID YOUR WARRANTY. CAUTION: DO NOT SWITCH SYSTEM TO COOL IF THE TEMPERATURE IS BELOW 50°F (10°C). THIS CAN DAMAGE THE AIR CONDITIONING SYSTEM AND CAUSE PERSONAL INJURY. COOL-OFF-HEAT 1. Place the COOL/OFF/HEAT switch into the COOL position 2. Press the ✞ button until the temperature setting is at least 3 degrees below the room temperature.
Resumen del contenido incluido en la página 10
Troubleshooting SYMPTOM REMEDY Thermostat does not Check Wiring turn on system (See INSTALLATION) Check fuse. Replace with 3 amp fuse if fuse has opened. Thermostat turns on and off Increase Temperature Differential too frequently. (See PROGRAMMING). Display is blank, flashing or Replace batteries. constant “LO BAT.” System fan does not Move fan option switch to either operate properly. gas or electric, to match system. (See INSTALLATION). Time shown on display is not Change time of day setting
Resumen del contenido incluido en la página 11
Five Year Limited Warranty Maple Chase Company warrants to the original contractor installer or to the original consumer user, each new Maple Chase thermostat to be free from defects in materials and workmanship under normal use and service for a period of five (5) years from date of purchase. This warranty does not cover batteries, damage caused by batteries, damage resulting from improper installation, alteration, misuse or abuse of the thermostat occurring after the date of purchase. Maple Ch