Resumen del contenido incluido en la página 1
3
B99A p1-19 2/7/03 9:58 AM Page 1
®
SINCE 1 8 8 6
AUTO SAVER 459
Owner’s Manual Model 44459
File: AJ570/41383 book p. 1-19/art Created: 9-28-98 db
PAGE 1
Folder: AJ570/Hunter/41383 Alt: 2-2-99 db
Prints black
2
2
5:
7
2
Resumen del contenido incluido en la página 2
Resumen del contenido incluido en la página 3
B99A p1-19 2/7/03 9:58 AM Page 3 Introduction CONGRATULATIONS! Please read this manual for complete instructions on installing and operating your thermostat. Your new Hunter electronic thermostat will provide years of reliable service. By saving energy, your thermostat will pay for If you require further assistance, call Hunter Technical Support itself during its first season of use. Thank you for buying a at 901-745-9222 from 8 am to 5 pm Central Time. Hunter product! Model Information: 4445
Resumen del contenido incluido en la página 4
B99A p1-19 2/7/03 9:58 AM Page 4 Table of Contents 4-5 INTRODUCTION Read This Before Installing Thermostat 6 Features 8 INSTALLATION What You Need 10 Remove Old Thermostat 10 Wire Labeling 11 Mount Wallplate and Thermostat 12 Selector Switches 14 PROGRAMMING Setting Time and Day 16 Auto Programming 17 Personal Program Schedule 18 Manual Programming 19 Weekday Programming 19 Saturday and Sunday Programming 21 Reviewing Programs 22 Reviewing the Current Temperature Setting 23 OPERATIONS System
Resumen del contenido incluido en la página 5
B99A p1-19 2/7/03 9:58 AM Page 5 Table of Contents (continued) OPERATIONS (continued) Temporary Manual Override 24 Permanent Manual (Vacation) Override 25 Auto Season Changeover 26 Home Today 26 Energy Monitor 28 Filter Monitor 29 Auto Recovery 30 Keyboard Lock 31 Backlighting 31 SAFETY FEATURES Low Battery Warning 32 Error Mode 33 Auto Cut-Off 33 TROUBLESHOOTING Problems & Solutions 34 Technical Support 35 WIRING DIAGRAMS Heat / Cool Systems 36 Single-Stage Heat Pump Systems 37 Heat Only / C
Resumen del contenido incluido en la página 6
B99A p1-19 2/7/03 9:58 AM Page 6 Read This Before Installing Thermostat 6-7 IMPORTANT represent most central heating, air conditioning, or space Read the entire installation section of this Owner’s heating units in use in the United States. 1Manual thoroughly before you begin to install or This Hunter Thermostat will NOT control multi-stage heat operate your Hunter Thermostat. pumps or 110/220 Volt systems. REMOVE THE MYLAR LABEL FROM THE LCD DISPLAY WINDOW. COMPRESSOR PROTECTION INSTALLATION
Resumen del contenido incluido en la página 7
B99A p1-19 2/7/03 9:58 AM Page 7 Read This Before Installing Thermostat (continued) POWER FAILURE have approximately 1 minute to change the batteries and Whenever the main power is interrupted or fails, the keep thermostat’s clock and program settings. Once the 7 battery power retains the programs and current time. batteries have become too low to ensure proper operation, your system will be turned Off, and the display will be cleared except for “BATT” flashing on the LCD display. AUTO RECOV
Resumen del contenido incluido en la página 8
Resumen del contenido incluido en la página 9
B99A p1-19 2/7/03 9:58 AM Page 9 For entering minute of day. For entering day of week. For entering hour of day. Reviews filter usage in HOUR MIN DAY hours and minutes. Also Enters Program Mode for resets filter counter to zero. reviewing and changing AUTO weekday or weekend PROG FILTER PROGRAM programs. Returns display to PROG HOLD current time and RETURN DAY CLEAR temperature. Selects the day or days to review or change in Program Mode. Automatically Provides permanent temperature setting b
Resumen del contenido incluido en la página 10
Resumen del contenido incluido en la página 11
Resumen del contenido incluido en la página 12
Resumen del contenido incluido en la página 13
RH B99A p1-19 2/7/03 9:58 AM Page 13 Connect Wires and Mount Thermostat Cover to Wall Plate Match and connect the labeled wires to the appropriate Insert the bottom tab on the thermostat body into the coded terminal screws on the mounting plate. (See slot at the bottom of the wallplate. Press top of the Figure 4, 5.) Ignore any wires which may be present, thermostat body to snap it into the wallplate. (NOTE: but which were not connected to the old thermostat. Do not force the
Resumen del contenido incluido en la página 14
HE HG B99A p1-19 2/7/03 9:58 AM Page 14 14-15 INSTALLATION Selector Switches In order for this Hunter thermostat to control your system, the If you have a single-stage Heat Pump (no auxiliary or system type must be specified by selector switches on the printed emergency heat source), then slide the switch to the position circuit board inside the thermostat. There are also other selector that matches your Reversing Valve type. If your heat pump switches that allow you to customize the fea
Resumen del contenido incluido en la página 15
B99A p1-19 2/7/03 9:58 AM Page 15 Feature Selector Switches: Heat mode, you can select +2°F / – 1°F by sliding the switch to the ALT position. This may be necessary if your heating system cycles too rapidly. F° / C° selector (Fahrenheit / Centigrade) – Switch 5 Your thermostat is set for F° mode from the factory. In order to Auto Recovery selector - Switch 8 change to C° mode, slide the switch to C° and press the reset button on front of the thermostat with a paper clip. Your thermostat i
Resumen del contenido incluido en la página 16
B99A p1-19 2/7/03 9:58 AM Page 16 PROGRAMMING 16-17 Setting Time and Day Remove the mylar label covering the LCD display window before operating thermostat. M T W Th F Sa Su SET TEMP Initial display after power-up or reset. The LCD will show the information C AM ° when batteries are first installed, or after the Reset button is pressed. The : PM 12 00 H temperature will update after a few seconds. C ° AUTO COOL HEAT TEMP 72 H During time and day setting mode, the temperature and prog
Resumen del contenido incluido en la página 17
B99A p1-19 2/7/03 9:58 AM Page 17 Auto Programming Studies conducted by the Department of Energy estimate that to Friday, to the same 4 programs as shown in the table, or each setting your thermostat back 10°F (6°C) for two 8-hour periods weekday can have a different set of 4 programs. Similarly weekend during winter can reduce your fuel bill by as much as 33%. By programs, Saturday and Sunday, can be the same 4 programs or setting your thermostat up 5°F (3°C) for two 8-hour periods each week
Resumen del contenido incluido en la página 18
B99A p1-19 2/7/03 9:58 AM Page 18 PROGRAMMING 18-19 Personal Program Schedule Before programming or changing programs, use this Personal Use a pencil so you can revise your records each time you Program Schedule to determine which times and temperature settings change your temperature settings. will best satisfy both your comfort and energy saving requirements. Heating Cooling Day Program 1 Program 2 Program 3 Program 4 Program 1 Program 2 Program 3 Program 4 Mon. Time Time Time Time Time Tim
Resumen del contenido incluido en la página 19
B99A p1-19 2/7/03 9:58 AM Page 19 Manual Programming Your thermostat can be programmed for weekdays and for NOTE: 1) The program time can be set in 10 minute Saturday and Sunday. Use the Programming steps below to increments, and remains the same for both Heat enter or revise programs to match your Personal Program and Cool programs. Schedule. The same steps are used when entering programs 2) The program temperature can be set in increments for the first time, or revising programs entered d
Resumen del contenido incluido en la página 20