Resumen del contenido incluido en la página 1
ふ
MS-70
MX-50
MF-50
ML-50
WM+PD4000477D
Resumen del contenido incluido en la página 2
1. 1. This manual and This manual and Mark Marks s 1. 1. This manual and This manual and Mark Marks s All safety messages are identified by the following, “WARNING” or “CAUTION”, of ANSI Z535.4 (American National Standard Institute: Product Safety Signs and Labels). The meanings are as follows: A potentially hazardous situation which, if not avoided, could WARNING result in death or serious injury. A potentially hazardous situation which, if not avoided, may result CAUTION in m
Resumen del contenido incluido en la página 3
Contents Contents Contents Contents 1. Safety and Compliance..................................................................3 2. Precautions...................................................................................5 2.1. Installing the Analyzer ..................................................................... 5 2.2. During Use ...................................................................................... 6 2.3. After Use and Maintaining the Analyzer ...........
Resumen del contenido incluido en la página 4
8. Check Function...........................................................................41 8.1. Self-Check Function....................................................................... 41 8.1.1. Operation.............................................................................................. 41 8.2. Test Sample (Sodium Tartrate Dihydrate) ....................................... 42 9. Connecting to a Printer ...............................................................43 9.1. P
Resumen del contenido incluido en la página 5
2. 2. Safety a Safety an nd Com d Compliance pliance 2. 2. Safety Safety a an nd Com d Comp pliance liance WARNING Do not use a sample that could make a dangerous chemical reaction and cause an explosion or poisonous gas, when the sample is dried. Keep flammables away from the analyzer. Parts of the analyzer become very hot. Materials placed near it might catch fire. Do not use the analyzer in ambient ignitable gas. It may cause explosion and fire. Use a power source (vol
Resumen del contenido incluido en la página 6
C C C Co o o ompli mpli mpli mpliance ance ance ance wit wit wit with h h h F F F FC C C CC R C R C R C Ru u u ule le le les s s s Please note that this device generates, uses and can radiate radio frequency energy. This device has been tested and has been found to comply with the limits of a Class A computing device pursuant to Subpart J of Part 15 of FCC rules. These rules are designed to provide reasonable protection against interference when this device is operated in a commercial
Resumen del contenido incluido en la página 7
3. 3. 3. 3. Pr Pr Pr Prec ec ec ecautions autions a autions utions 3. 3. 3. 3.1 1 1 1.... IIIIn n n ns s s st t t tall all all alliiiin n n ng g g g the Ana the Ana the Ana the Anallllyz yz yz yzer er er er --- --- --- ---C C C Ca a a auti uti uti utio o o on for M n for M n for M n for Mea ea ea easure sure sure surement me me ment Saf nt Saf nt Safety Safety e et ty y --- --- --- --- Do not install the analyzer in a dangerous place. Maintain the following ambient cond
Resumen del contenido incluido en la página 8
3. 3.2 2.. Du Dur riin ng g Use Use 3. 3.2 2.. Du Dur riin ng g Use Use --- --- --- ---C C C Ca a a auti uti uti utio o o on for M n for M n for M n for Mea ea ea easure sure sure sureme me me ment Sa nt Sa nt nt Sa Safety fety --- fety fety --- --- --- Grip of heater Operate the analyzer using the following procedure. cover Put the sample pan in the correct position. Grip of pan Handle the grip of the heater cover to open and handle close it. Use the pan handle to move
Resumen del contenido incluido en la página 9
Resumen del contenido incluido en la página 10
4. 4. Outline and Outline and Fe Features atures 4. 4. Outl Outline and ine and Fe Featu atur re es s The moisture analyzer is built using a super hybrid sensor (S.H.S.) adopted in an analytical balance. Therefore, the result is more precise and gets greater repeatability. An analyzer using the S.H.S. has high sensitivity, needs only a sample quantity of a few grams, and the analysis time becomes shorter. A 400W halogen lamp is used as the heating source and the temperatur
Resumen del contenido incluido en la página 11
The analyzer is equipped with a serial interface as standard. It can be connected to a printer or computer. The analyzer can calibrate the weighing sensor (Use special mass.) and drying temperature (Use temperature calibrator for MS-70 and MX-50 except MF-50 and ML-50). The analyzer can output the data required at GLP, GMP and ISO at the end of the calibration. The analyzer has a self check function that can detect function errors. The analyzer displays the current change of
Resumen del contenido incluido en la página 12
Resumen del contenido incluido en la página 13
Resumen del contenido incluido en la página 14
5. 5. 5. 5.1 1 1 1.... Di Di Di Dis s s sp p p plllla a a ay y y y a a a an n n nd d d d Ke Ke Ke Key y y ys s s s 4 5 6 7 3 8 2 9 1 10 #2 Name State and Meaning At gram display Preset time is displayed at timer mode 1 Time At measurement Analysis time Temperature of At gram display Set temperature of sample pan 2 sample pan At measurement Current temperature of sample pan PROG: Program No. At gram display Program number of measurement program 3 MEM: Data
Resumen del contenido incluido en la página 15
Resumen del contenido incluido en la página 16
6. 6. P Pr reparation eparations s 6. 6. P Pr reparation eparations s 6. 6.1 1.. IIn ns st tall alliin ng g the Ana the Anallyz yzer er 6. 6.1 1.. IIn ns st tall alliin ng g the Ana the Anallyz yzer er 1. Select the place to install the analyzer. Bubble spirit level Refer "3.1.Installing the Analyzer". 2. Level the analyzer by adjusting the leveling feet and confirm it using the bubble spirit level. Leveling foot 3. Read the power supply voltage label on the back
Resumen del contenido incluido en la página 17
Resumen del contenido incluido en la página 18
6. 6.3 3.. Pr Proper oper O Op per era at tiio on f n fo or r Pr Prec ecis isiio on Me n Mea as sure urem me en nt t 6. 6.3 3.. Pr Proper oper O Op per era at tiio on f n fo or r Pr Prec ecis isiio on Me n Mea as sure urem me en nt t 6.3.1. 6.3.1. 6.3.1. 6.3.1. Operation of Operation of Operation of Operation of the sample the sample the sample the sample Use a proper sample quantity. If the quantity is small, precise results may not be possible. If the moisture content of the s
Resumen del contenido incluido en la página 19
6. 6.3. 3.3. 3. T Th he G e Glla as ss F s Fiibe ber r S Sh hee eet ts s 6. 6.3. 3.3. 3. T Th he G e Glla as ss F s Fiibe ber r S Sh hee eet ts s Use the glass fiber sheet to measure the moisture content that is included in the following samples. When this sheet is used, vaporization of moisture is speeded up and moisture measurement result becomes quick and precise. This accessory (AX-MX-32-1) is a package of 100 glass fiber sheets. This accessory is inclued in the packing for
Resumen del contenido incluido en la página 20
7. 7. Meas Measur urement Pr ement Proce oced dur ure e 7. 7. Meas Measur urement Pr ement Proce oced dur ure e 7. 7.1 1.. S St tan and da ard rd M Mo od de e O Op pe er rat atio ion n 7. 7.1 1.. S St tan and da ard rd M Mo od de e O Op pe er rat atio ion n The standard mode can obtain the moisture content with settings of ACCURACY and drying program (heating pattern, drying temperature). 7.1.1. 7.1.1. 7.1.1. 7.1.1. ACCURAC ACCURAC ACCURAC ACCURACY Y Y Y ACCURACY of mea