Resumen del contenido incluido en la página 1
flexible infrared
thermometer
model 94233
assembly and operating instructions
Visit our website at: http://www.harborfreight.com
read this material before using this product.
failure to do so can result in serious injury.
sa Ve this manual.
© ®
Copyright 2006 by Harbor Freight Tools . All rights reserved. No portion of this manual or any artwork con-
tained herein may be reproduced in any shape or form without the express written consent of Harbor Freight
Tools. Diagrams within this manua
Resumen del contenido incluido en la página 2
Specifications Features Flexible 14-1/8” Shaft LCD w/White Backlight, Display Auto Data Hold Laser Guide Automatic (no indication for Polarity positive polarity): Minus (-) LASER LIGHT DO NOT STARE INTO BEAM sign for negative polarity Max. Output: 1mW, -58°F to 1112°F Measurement Range Wavelength: 650 nm (-50°C to 600°C) CLASS II LASER PRODUCT This product complies with (0.1° up to 200°, Resolution 21 CFR 1040.10 and 1040.11 1° over 200 °) CEN-TECH 3491 Mission Oaks Blvd., Power Supply 9V Batt
Resumen del contenido incluido en la página 3
8. Maintain tools with care. Keep the Flexible Infrared Thermometer clean for better and safer performance. The handle must be kept clean, dry, and free from oil and grease at all times. 9. Disconnect power. Turn off tool when not in use. Remove battery when not in use for a week. 10. Stay alert. Watch what you are doing, use common sense. Do not operate any tool when you are tired. 11. Check for damaged parts. Before using any tool, any part that appears damaged should be carefully ch
Resumen del contenido incluido en la página 4
Operation Preparing to Take Measurements Warning! Laser radiation is dangerous and can cause permanent eye damage. Do not stare into the beam or point it at others. Note: You will need to set the “C” or “F” key (5) to establish an LCD readout in either Fahrenheit or Celsius. Refer to the Assembly Drawing on page 8. 1. The Thermometer automatically powers ON when the Measuring Key (7) is selected. The Thermometer will power OFF automatically approximately 7 seconds after the Measuring Key
Resumen del contenido incluido en la página 5
4. The Thermometer will automatically hold the last temperature reading for seven seconds after pressing the Measuring Key (7) is pressed and released. No extra keys need to be pressed to freeze the display reading on the LCD. See Figure 3. 5. To show the backlighting, first press the Measuring Key (7) and then press the Backlight Key (6). Press the Laser Key (4) while pressing the Measuring Key (7) to turn the Laser Pointer (2) ON which will activate the Infrared Sensor (1). Press the Laser
Resumen del contenido incluido en la página 6
Battery Replacement Note: The LCD will indicate the battery is weak with a flashing display. See Figure 6.. 1. Remove the Screw on the back of the unit to remove the battery compartment lid. (Screwdriver not provided). 2. Replace the battery, making sure the polarity connections on the battery correspond to the polarity in the battery compartment. Snap the battery in place. Reattach the lid back onto the unit. Tighten the Screw to secure. See Figure 7. 3. Replace the battery with only a new
Resumen del contenido incluido en la página 7
Emissivity 1. Most organic materials and painted or oxidized surfaces have an emissivity of 0.95 (pre-set in the unit). Inaccurate readings will result from measuring a shiny or polished metal surface. See recommendations on page 6 for obtaining an accurate reading and refer to the chart below. Maintenance 1. Keep the unit clean. Wipe it down with a lint free cloth. 2. Make sure the laser is clear of any dirt or debris. 3. Remove the battery if you are not using the unit for extended periods
Resumen del contenido incluido en la página 8
Parts List Assembly Drawing Part 1 Part # Description QTY Part 2 1 Infrared Sensor 1 2 Laser Pointer Beam 1 3 LCD Display 1 4 Laser Key 1 5 Celsius or Fahrenheit Select Key 1 6 Backlight Select Key 1 7 Measuring Key 1 8 Battery Compartment 1 9 Carrying Case (no shown) 1 Part 3 Part 4 Part 6 Part 5 Part 7 Part 8 Note: No replacement parts available for this unit. PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS MANUAL AS A REFER
Resumen del contenido incluido en la página 9
limited 90 day Warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installatio