Resumen del contenido incluido en la página 1
Hoshizaki America, Inc.
Hoshizaki
Modular Flaker
Models
FD-1001MAH(-C)
FD-1001MWH(-C)
FD-1001MRH(-C)
FD-1001MLH(-C)
SERVICE MANUAL
“A Superior Degree
of Reliability”
www.hoshizaki.com
Number: 73159
Issued: 2-12-2010
Resumen del contenido incluido en la página 2
IMPORTANT Only qualified service technicians should install, service, and maintain the icemaker. No service or maintenance should be undertaken until the technician has thoroughly read this Service Manual. Failure to service and maintain the equipment in accordance with this manual may adversely affect safety, performance, component life, and warranty coverage. Hoshizaki provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.
Resumen del contenido incluido en la página 3
IMPORTANT This manual should be read carefully before the icemaker is serviced or maintenance operations are performed. Only qualified service technicians should install, service, and maintain the icemaker. Read the warnings contained in this booklet carefully as they give important information regarding safety. Please retain this booklet for any further reference that may be necessary. CONTENTS Important Safety Information ........................................................................
Resumen del contenido incluido en la página 4
3. Alarm Safeties ....................................................................................................... 30 a) Low Water Safety (1-beep alarm) .................................................................... 30 b) Control Switch in the "DRAIN" Position (-beep alarm) ................................... 30 c) High Pressure Switch (3 & 4-beep alarms) ...................................................... 30 d) Freeze Timer (5-beep alarm) .......................................
Resumen del contenido incluido en la página 5
IV. Service Diagnosis .......................................................................................................... 58 A. Ice Production Check .................................................................................................. 58 B. Diagnostic Procedure ................................................................................................. 58 C. Control Board Check ..............................................................................................
Resumen del contenido incluido en la página 6
VI. Cleaning and Maintenance ............................................................................................ 96 A. Cleaning and Sanitizing Instructions ........................................................................... 96 1. Cleaning Solution .................................................................................................. 96 . Cleaning Procedure ............................................................................................... 96 3. Sanitizin
Resumen del contenido incluido en la página 7
Important Safety Information Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit. WARNING Indicates a hazardous situation which could result in death or serious injury. CAUTION Indicates a situation which could result in damage to the unit. IMPORTANT Indicates important information about the use and care of the unit. WARNING This icemaker should be destined only to the use for which it has been e
Resumen del contenido incluido en la página 8
I. Specifications A. Icemaker 1. FD-1001MAH (air-cooled) Awaiting Data Note: We reserve the right to make changes in specifications and design without prior notice. 8
Resumen del contenido incluido en la página 9
2. FD-1001MAH-C (air-cooled) AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR 240 V 4.2 RLA 34 LRA GEAR MOTOR 120 V 3 FLA 1/4 HP FAN MOTOR 115 V 0.85FLA 1/15 HP OTHER 120 V 0.03A MAXIMUM FUSE SIZE 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKER (CANADA ONLY) 15 A MINIMUM CIRCUIT AMPACITY 15 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 *940 (427) 890 (405) 855 (389) Reference without *marks 80
Resumen del contenido incluido en la página 10
3. FD-1001MWH (water-cooled) Awaiting Data Note: We reserve the right to make changes in specifications and design without prior notice. 10
Resumen del contenido incluido en la página 11
4. FD-1001MWH-C (water-cooled) Awaiting Data Note: We reserve the right to make changes in specifications and design without prior notice. 11
Resumen del contenido incluido en la página 12
5. FD-1001MRH (remote air-cooled) Awaiting Data Note: We reserve the right to make changes in specifications and design without prior notice. 1
Resumen del contenido incluido en la página 13
6. FD-1001MRH-C (remote air-cooled) AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR 240 V 4.2 RLA 34 LRA GEAR MOTOR 120 V 3 FLA 1/4 HP FAN MOTOR REMOTE 115 V 3A MAX OTHER 120 V 0.03A MAXIMUM FUSE SIZE 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKER (CANADA ONLY) 15 A MINIMUM CIRCUIT AMPACITY 15 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 *930 (423) 895 (406) 860 (390) Reference without *mark
Resumen del contenido incluido en la página 14
7. FD-1001MLH (low side, parallel rack system) Awaiting Data Note: We reserve the right to make changes in specifications and design without prior notice. 14
Resumen del contenido incluido en la página 15
8. FD-1001MLH-C (low side, parallel rack system) Awaiting Data Note: We reserve the right to make changes in specifications and design without prior notice. 15
Resumen del contenido incluido en la página 16
B. Condenser Unit 1. URC-5F a) Specifications AC SUPPLY VOLTAGE 115/60/1 (Connection to Icemaker) FAN MOTOR 115 V Total 1.3FLA 65W EXTERIOR DIMENSIONS (WxDxH) 21-15/16" x 15-11/16" x 17-7/8" (557 x 398 x 454 mm) DIMENSIONS INCLUDING LEGS (WxDxH) 24" x 18-1/8" x 32-13/16" (610 x 460 x 834 mm) EXTERIOR FINISH Galvanized Steel WEIGHT Net 61 lbs. ( 28 kg ) Shipping 68 lbs. ( 31 kg ) CONNECTIONS - ELECTRIC Permanent - Connection - REFRIGERANT Discharge Line 1-1/16"
Resumen del contenido incluido en la página 17
b) Dimensions 24" (610 mm) 23-1/32" (585 mm) 19-11/16" 6/16" × 3/4" (10×20 mm) (500 mm) 4×2 (SLOTTED HOLES) 18-1/8" (460 mm) 20-15/32" (520 mm) 21-15/16" (557 mm) 7/8" DIA. HOLE (23 mm DIA.) 6-5/16" (160 mm) 2-15/16" (75 mm) 17 Unit: in. (mm) 18-1/8" (460 mm) 14-15/16" 17-7/8" 17-1/8" (380 mm) (454 mm) (435 mm) 14-9/16" 2-1/2" (370 mm) (63 mm) 14-1/8" (358 mm) 14-15/16" (380 mm) 15-11/16" (398 mm)
Resumen del contenido incluido en la página 18
II. General Information A. Construction 1. FD-1001MAH(-C) (air-cooled) Mechanical Bin Control Inlet Water Valve Control Box Spout Extruding Head Heater (FD-1001MAH-C) Evaporator Fan Motor Expansion Air-Cooled Valve Condenser Gear Motor Ice Chute Compressor Infrared Sensor 18
Resumen del contenido incluido en la página 19
2. FD-1001MWH(-C) (water-cooled) Mechanical Bin Control Inlet Water Valve Control Box Spout Extruding Head Heater (FD-1001MWH-C) Evaporator Water Expansion Regulating Valve Valve Water-Cooled Condenser Gear Motor Ice Chute Compressor Infrared Sensor 19
Resumen del contenido incluido en la página 20
3. FD-1001MRH(-C) (remote air-cooled) Mechanical Bin Control Inlet Water Valve Control Box Spout Extruding Head Heater (FD-1001MRH-C) Evaporator Expansion Valve Gear Motor Ice Chute Compressor Infrared Sensor 0