PERFECTAIRTPURIFIER
SIZES1625AND2025
Installation,Start--Up,and
Operating Instructions
NOTE: Read the entire instruction manual before starting the
install.
Thissymbol →indicatesachangesincethelastissue.
TABLEOFCONTENTS
Page
INTRODUCTION .................................. 1
HOW IT WORKS .................................. 1
SAFETY CONSIDERATIONS ........................ 1
APPLICATION CONSIDERATIONS .................. 2
INSTALLATION ................................. 3--5
START--UP AND OPERATI
Resumen del contenido incluido en la página 2
Transitions APPLICATIONCONSIDERATIONS If the return air duct or furnace openings do not fit the Perfect The Perfect Airt Purifier is designed for use in the return air Airt Purifier cabinet openings, gradual transitions are duct of a forced air heating, cooling, and ventilation system. recommended to reduce air turbulence and maximize efficiency. Models GAPAAXBB1625 and GAPAAXBB2025 are No more than 20 degrees (about 4 in. per running ft) of specifically designed for use in systems with a forced
Resumen del contenido incluido en la página 3
Step7—IdentifyMountingLocation INSTALLATION a. IdentifyamountingorientationforthePerfectAirt Step6—CheckPerfectAirtPurifierComponents Purifierinthereturnairduct(seeFig.3). b. EnsureairflowdirectionthroughthePerfectAirtPurif- ! CAUTION iermatchesthearrowsonthefaceoftheairpurifier cartridge.ThePerfectAirtPurifiercanberotated180 CUT HAZARD degreestoaccommodatethecabinetorientation. Failure to followthis cautionmay result in personal injury. c. ThelocationofthePerfectAirtPurifiershouldbe readilyacce
Resumen del contenido incluido en la página 4
a. Turnoffpowertotheheatingandcoolingsystem. Step8—MounttheCabinet b. Removetheexistingfurnacefilteranddiscard. ExcessivesystemstaticmayresultifthePerfectAirt Purifierisusedwithotherfiltrationdevices. c. Removetheairpurifiercartridgeandenhancement ! WARNING modulefromthePerfectAirtPurifiercabinet. d. Positionthecabinetbetweenthefurnaceandreturnair ELECTRICALSHOCKHAZARD duct(seeFig.4).Atransitionductmayberequired. Failuretofollowthiswarningcouldresultinpersonalinjury ordeath. e. Furnaceadaptersha
Resumen del contenido incluido en la página 5
a. Ensurepowerhasbeenremovedfromtheheatingand Furnace Adapters coolingsystem. b. TurnthePerfectAirtPurifierpowerswitchoff. c. Connectthepowercordtothepowersupplyconnector (seeFig.7). d. Routethepowercordthroughnearestcabinetholeand protectwithenclosedcableconnector.Ziptieshave beenenclosedtosecurethepowercordtothesideofthe Airflow powersupply. e. Attachthequickconnectterminalstothefurnace EAC--1andEAC--2spadeconnections.Attachthe groundringtofurnacechassisground. Airflow A05274 Fig.5-- UseofFurn
Resumen del contenido incluido en la página 6
O C S IHI/LOR IDM PL3 1 HSIR 1 PL2 IDR L1 ACRDJ PL1 1 1 2 3 ON PLT OFF W2 Y1 DHUM G COM WW1 Y/Y2 R HI HEAT LO HEAT 24V U T A T Power Cord Sample Furnace Circuit Board to EAC Terminals LHT OFF DLY Use cable connector to secure power cord to cabinet Power Supply Connector Power Supply Connector TEST/TWIN Use terminals to connect the power cord wires to the furnace HUM 0.5-AMP024 VAC Power Supply EAC-1 & 2, & ground terminals Power Cord FUSE 3-AMP SEC-1 SEC-2 EAC-2 TERMINAL Use wire ties to
Resumen del contenido incluido en la página 7
Step1—Turntheheatingandcoolingsystemoff. TROUBLESHOOTING ! WARNING ! CAUTION ELECTRICALSHOCKHAZARD SAFETYHAZARD Failure to follow this warning could result in personal Failure to follow this caution may result in personal injuryordeath. injury or equipment damage. Before installing or servicing system, always turn off The following instructions are for use by qualified main power to system. There may be more than one (1) personnel only. disconnect switch. Step2—TurnthePerfectAirtPurifierswitchto
Resumen del contenido incluido en la página 8
SpecificationsandDimensions Specifications GAPAAXBB1625 GAPAAXBB2025 Color Taupe Metallic Taupe Metallic CabinetMaterial 20 Ga.PowderCoated Steel 20 Ga.PowderCoated Steel Electrical 115v/60 Hz (from furnace EAC terminals) 115v/60 Hz (from furnace EAC terminals) MaximumAirflow(CFM) 1600 2000 Efficiency EquivalenttoMERV15 EquivalenttoMERV15 ReplacementCartridge GAPBBCAR1625 GAPBBCAR2025 Dimensions GAPAAXBB1625 GAPAAXBB2025 A 18---3/8 21---7/8 B 15---1/8 18---5/8 C 11---1/8 11---1/8 D 17---1/2 21 E
Resumen del contenido incluido en la página 9
Bryant Heating & Cooling Systems FOR SERVICE OR REPAIR, FOLLOW THESE STEPS IN ORDER: FIRST: Contact the installer. You may find their name on the furnace or in your Homeowner’s Packet. If the installer’s name is not known, call your builder or home retailer if yours is a new residence. SECOND: Contact the nearest distributor. (See telephone yellow pages.) THIRD: Contact: Bryant Heating and Cooling Systems Consumer Relations P.O. Box 4808 Syracuse, New York 13221 Phon
Resumen del contenido incluido en la página 10
EBryantHeating &Cooling Systems 7310 W.Morris St. Indianapolis,IN 46231 Printedin China Edition Date: 3/06 CatalogNo.IIGAPA---0---2 Manufacturerreserves the righttodiscontinue,orchange atany time,specifications ordesigns withoutnotice andwithoutincurring obligations. Replaces: II GAPA---0---1 10 GAPA