Solenoid Valve Replacement for 1030/1031 Compressor
INTRODUCTION
KEISER CORPORATION has always taken pride in designing and engineering the
highest quality equipment on the market. This means that you will receive years of low
maintenance and minimal repairs from every one of our machines. Only the highest
quality products have the KEISER name on them.
WORD DEFINITIONS
SAFETY CAUTIONS and WARNINGS:
We've put a number of safety cautions in this book. We use the word Caution! to tell you
about
Resumen del contenido incluido en la página 2
Solenoid Valve Replacement for 1030/1031 Compressor *WARNING: Unplug compressor before beginning. Before replacing valve, draw all of the air out of the compressor by pressing both the + and – buttons on the exercise equipment. When this is done, shut off valve to exercise equipment by turning the red handle clockwise. When the valve has been turned off, it should be parallel to the compressor like this: The Mac® valve cannot be cleaned. Therefore, once faulty, it must be replaced. The Al
Resumen del contenido incluido en la página 3
Step Two: Remove hoses After the screws have been removed, take the ½ inch open-ended wrench, and loosen the nut that connects the hose to the valve by turning it counter-clockwise, and remove the hose. Unscrew nut counter-clockwise Next, cut the hose to the plastic elbow 3/8 inch from the end of the plastic elbow using the wire cutter. cut tubing Repeat steps one and two to dismount the second valve before proceeding to step three. Step Three: Remove electrical wires First, clip the zip tie tha
Resumen del contenido incluido en la página 4
Next, remove the lid to the computer control system box by unscrewing the screw on either side. remove two screws on lid Then remove the rubber grommet by using the needle nose pliers to carefully pop it out of the hole. pop out grommet Inside the computer control system box, cut all other zip ties holding the four wires. Trace each of the wires from the valve to the circuit board. There are two per valve, four wires total. The connectors are marked V1 and V2 on the circuit board. Remove each
Resumen del contenido incluido en la página 5
1030 Circuit Board Diagrams Rev A, B, C Rev D - Current 10-5508 Rev A Service Department (800) 888-7009 5
Resumen del contenido incluido en la página 6
push on board, pull on wire Pull each of the four wires back out the hole one by one. Save the rubber grommet. There are four steps to Allenair® valve installation: 1 Adjust and mount new valve 2 Install single to double splitter and electrical wires 3 Secure and tie wires and replace lid 4 Test compressor 5 Note: Keep two things in mind when you are ready to install the new valves. First, the new valve requires a different mount. Second, the electrical wiring requires the installation of a s
Resumen del contenido incluido en la página 7
Step One: Adjust and mount new valve First, make sure that the valve is open. Try to turn the pet-cock on the valve counter- clockwise. If you cannot turn it further counter-clockwise, it is open. open valve counter-clockwise The new valve allows you to rotate its housing for easy mounting. Use the ½ inch open-ended wrench to loosen the nut on the top of the new valve. Loosen it just enough that you can rotate the red metal housing of the valve. turn nut counter-clockwise By adjusting the hou
Resumen del contenido incluido en la página 8
Next, remove the compression nut that connects the hose to the valve. Replace it with the original compression nut, attach the hose, and tighten the compression nut finger tight. Take the ½ inch wrench and rotate the nut ½ to ¾ turn. Attach the second hose to the plastic elbow by using the needle nose pliers to push the hose all the way onto the plastic elbow. If you do not properly attach the hose, the pressure from the compressed air will force the hose off the elbow. push all the way down
Resumen del contenido incluido en la página 9
Left side valve Right side valve Repeat the process under Step One to mount the second valve. Step Two: Install single to double adapter and electrical wires Take all four electrical wires and insert them, one by one, through the rubber grommet, and then through the hole. Pull all of the slack into the computer system control box. Replace the grommet in the hole. Next, install the single to double adapter. Approach the compressor from the front
Resumen del contenido incluido en la página 10
Step Two: Install single to double adapter and electrical wires Take all four electrical wires and insert them, one by one, through the rubber grommet, and then through the hole. Pull all of the slack into the computer system control box. Replace the grommet in the hole. Next, install the single to double adapter. Approach the compressor from the front. The electrical plug and air valve are on the front. Front of compressor Grasp the connector located on the left hand side of the circuit boar
Resumen del contenido incluido en la página 11
Take the single to double adapter and turn it so that the two top prongs are pointing to the left hand side of the box. The bent portion with these two prongs should be over the fuse. Replace the connector with the single to double adapter in L1. single to double adapter Reconnect the connector that was removed from L1 onto either of the prongs atop the single to double adapter. Next, pull the two wires that lead to the valve on your right back to the hole in the box. This prevents crossing the
Resumen del contenido incluido en la página 12
Step Three: Secure and tie wires and replace lid Make sure that all of the slack is inside the computer control system box. Use a zip tie to bind the wires and hoses on the outside of the box. Use the wire cutters to cut off the excess. zip tie all wires and hoses Next, gather the four wires inside the box, and arrange them so that the small grey LED on either side of the box is not blocked from view. Tie these wires using two or more zip ties. Cut the excess from the ties. secure wires to c
Resumen del contenido incluido en la página 13
feel for air flow After the flow of air has stopped, wait thirty seconds. Slowly lower the air in the compressor to approximately 95 PSI and the compressor should start. Open the valve by turning the handle counter-clockwise to allow the air to reach the equipment. Open valve by turning counter-clockwise until the handle is directly above the valve. 10-5508 Rev A Service Department (800) 888-7009 13
Resumen del contenido incluido en la página 14