Resumen del contenido incluido en la página 1
COMPRESSOR AND
AIR BRUSH KIT
Model 95630
SET UP AND OPERATING INSTRUCTIONS
Visit our website at: http://www.harborfreight.com
Read and understand tool labels and
manual. Failure to follow warnings could
result in DEATH or SERIOUS INJURY.
SAVE THIS MANUAL.
© ®
Copyright 2010 by Harbor Freight Tools . All rights reserved. No portion of this manual or any artwork
contained herein may be reproduced in any shape or form without the express written consent of
Harbor Freight Tools. Diagram
Resumen del contenido incluido en la página 2
CAUTION, without the SAVE THIS MANUAL safety alert symbol, is Keep this manual for the safety warnings used to address practices not and precautions, assembly, operating, related to personal injury. inspection, maintenance and cleaning procedures. Write the product’s serial number Symbol Definitions in the back of the manual near the assembly diagram (or month and year of purchase if Symbol Property or statement product has no number). Keep this manual Pounds per square inch of pres
Resumen del contenido incluido en la página 3
moving parts. Damaged or entangled General cords increase the risk of electric shock. a. To reduce the risks of electric shock, e. When operating a power tool fire, and injury to persons, read all the outdoors, use an extension cord instructions before using the tool. suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk Work area of electric shock. a. Keep the work area clean and well f. If operating a power tool in a damp lighted. Cluttered benches and da
Resumen del contenido incluido en la página 4
persons. A tool is dangerous in the e. Use safety equipment. A hands of untrained users. dust mask, non-skid safety shoes and a hard hat must be f. Maintain the tool with care. A properly used for the applicable maintained tool reduces the risk of conditions. Wear heavy-duty work binding and is easier to control. gloves during use. g. Check for misalignment or binding f. Always wear eye protection. of moving parts, breakage of parts, Wear ANSI-approved safety and any other condit
Resumen del contenido incluido en la página 5
8. Do not stand or sit on the Air Specific Safety Instructions SPECIFIC SAFETY S Compressor. Serious injury could result if the Compressor is tipped. 1. Maintain labels and nameplates on the tool. These carry important information. 9. Do not leave the Air Compressor If unreadable or missing, contact Harbor unattended when it is plugged in. Freight Tools for a replacement. Turn off the Compressor and unplug before leaving. 2. DANGER! This Air Compressor is NOT equipped and should no
Resumen del contenido incluido en la página 6
ground fault interrupt (GFCI) system SAVE THESE is also a good precaution. This INSTRUCTIONS. inexpensive device is a good safety Groun measure because it prevents a sustained ding electrical shock. Grounding • Properly maintain and inspect all tools before use to avoid electrical shock 16. Never leave the tool unattended when TO PREVENT ELECTRIC it is plugged into an electrical outlet. SHOCK AND DEATH Turn off the tool, and unplug it from its FROM electrical outlet before le
Resumen del contenido incluido en la página 7
If the tool should electrically malfunction 2. Double insulated tools may be used in or break down, grounding provides a either of the 120 volt outlets shown in the low resistance path to carry electricity preceding illustration. away from the user, reducing the risk (See Outlets for 2Prong Plug.) ‑ of electric shock. (See 3Prong ‑ Plug and Outlet.) Extension Cords 1. Grounded tools require a three wire 2. The grounding prong in the plug is extension cord. Double Insulated connected t
Resumen del contenido incluido en la página 8
Description Symbology Functional Description Double Insulated Compressor Specifications Canadian Standards Association Type Single cylinder, oiless piston Power 1/5 HP Voltage 120, 60HZ, 1.18 AMP Underwriters Laboratories, Inc. Thermo-Overload Auto shutoff shutoff protection Volts Alternating Current V~ Air output 0 - 58 PSI Air outlet size 1/8 - 27 NPT male threads Amperes A Motor RPM 1750 No Load Revolutions per Minute Pressure Gauge 0-100 PSI n xxxx/min. 0 (RPM) Cord length 6’-2 1/2”L W
Resumen del contenido incluido en la página 9
tripping hazard or exposing the air hose Assembly Initial Tool Setup/Assembly to possible damage. The air hose must be long enough to reach the work area with enough extra length to allow free Read the ENTIRE movement while working. IMPORTANT SAFETY INFORMATION section at the 3. Secure loose workpieces using a vise beginning of this manual or clamps (not included) to prevent including all text under movement while working. subheadings therein before set up or use of this product.
Resumen del contenido incluido en la página 10
Lever (10A)) and the fluid will atomize. OFF Power Switch (34) and unplugging Continue to move the Finger Lever (10A) the Compressor from the 120 V power to achieve the air volume you need for supply, or from your extension cord. your spray technique. NOTE: The 5cc Metal Cup (28A) has two 7. Continue to adjust the spray volume by uses. It is used for excess thinned paint, using the Finger Lever (10A), moving it and also for solvent when it is time to front to back. When you have the corre
Resumen del contenido incluido en la página 11
clean and wipe down Airbrush and all Ring and Inlet and Outlet Valves. Please that were used during operation. note: This work should only be done by a qualified service technician. 3. AFTER EVERY 500 HOURS OF REGULAR USE, replace Compression Troubleshooting Problem Possible Causes Likely Solutions Air Compressor 1. No power at outlet. 1. Check power at outlet. will not start. 2. Cord not connected. 2. Check that cord is plugged in. Pressure is low 1. Air connection is leaking. 1. Seal air
Resumen del contenido incluido en la página 12
Compressor Parts List and Assembly Diagram Part Description Qty Part Description Qty 1 Screw 8 22 Front Cover 1 2 Rear cover 1 23 Water Drain Valve 1 4 Rear Body 1 24 O-Ring 1 5 Screw 4 25 Cylinder Block 1 6 Stationary Motor 1 26 O-Ring 1 7 Bearing 2 27 Cylinder Head 1 8 Rotary Motor 1 28 Cap Screw 4 9 Front Body 1 29 Filter 1 10 Counterweight 1 30 Handle 1 11 Manometer 1 31 Pressure Switch 1 12 Bearing 1 32 Pressure Regulator 1 13 Retainer Ring 1 33 Condenser 1 14 Compression Ring 1 34 Power Sw
Resumen del contenido incluido en la página 13
Air Brush Parts List and Assembly Diagram Part Description Qty Part Description Qty 1A Protective Cap 1 17A Spring 1 2A Air Cap 1 18A Needle 1 3A Nozzle 1 19A O-Ring 1 4A Air Cap Body 1 20A Valve Rod 1 5A O-Ring 1 21A O-Ring 1 6A Packing 1 22A Spring 1 7A Packing Nut 1 23A Valve Screw 1 8A Air Brush Housing 1 24A Valve Body 1 9A Needle Adjustment Screw 1 25A Hose Connector Nut 1 10A Finger Lever 1 26A O-Ring for Hose Connector 1 11A Rocker 1 27A Hose Connector 1 12A Needle Adjusting Sleeve 1 28A
Resumen del contenido incluido en la página 14
Limited 1 Year Warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of one year from the date of purchase (90 days if used by a professional contractor or if used as rental equipment). This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repair