Resumen del contenido incluido en la página 1
AD-670 Installation Manual
Phase 7 / Gas Only
WARNING: For your safety the information in AVERTISSEMENT: Assurez-vous de bien
this manual must be followed to minimize the suivre les instructions données dans cette notice
pour réduire au minimum le risque d’incendie
risk of fire or explosion or to prevent property
damage, personal injury or death. ou d’explosion ou pour éviter tout dommage
matériel, toute blessure ou la mort.
— Do not store or use gasoline or other flammable — Ne pas entreposer
Resumen del contenido incluido en la página 2
Retain This Manual In A Safe Place For Future Reference American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation. ONLY qualified technicians should service this equipment. OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer. The following “FOR YOUR SAFETY” caution must be po
Resumen del contenido incluido en la página 3
IMPORTANT YOU MUST DISCONTINUE AND LOCKOUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY BEFORE ANY COVERS, GUARDS, OR DOORS ARE REMOVED OR OPENED TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS. «Attention: Au moment de l’entretien des commandes, étiquetez tous les fils avant de “Caution: Label all wires prior to les débrancher. Des erreurs de câblage disconnection when servicing controls. Wiring pe
Resumen del contenido incluido en la página 4
WARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESULT. WARNING DRYER MUST NEVER BE OPERATED WITHOUT THE LINT DRAWERS IN PLACE, EVEN IF AN EXTERNAL LINT COLLECTION SYSTEM IS USED. IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer. Dryers must not be installed or stored in an area where it will be exposed to water or w
Resumen del contenido incluido en la página 5
Table of Contents SECTION I IMPORTANT INFORMATION ............................................................................ 3 A. Receiving and Handling ........................................................................................................... 3 B. Safety Precautions .................................................................................................................. 4 SECTION II SPECIFICATIONS AND DIMENSIONS .......................................................
Resumen del contenido incluido en la página 6
SECTION VII DATA LABEL INFORMATION .......................................................................... 29 A. Data Label........................................................................................................................... 29 SECTION VIII GAS TRAIN AND BURNER DESCRIPTION AND OPERATION................. 31 A. Pilot Gas Supply Line ........................................................................................................... 31 B. Main Gas Supply Line .......
Resumen del contenido incluido en la página 7
SECTION I IMPORTANT INFORMATION A. RECEIVING AND HANDLING The dryer is shipped in three (3) pieces with protective stretch wrap, protective cardboard corners, and top covers as a means of preventing damage in transit. Upon delivery, the individual pieces and/or packaging, and wooden skids should be visually inspected for shipping damage. If any damage whatsoever is noticed, inspect further before delivering carrier leaves. Dryers damaged in shipment: 1. ALL dryers should be inspected upon rec
Resumen del contenido incluido en la página 8
B. SAFETY PRECAUTIONS WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. WARNING: The dryer must never be operated with any of the safety guards, service panels, or service doors removed or open. PERSONAL INJURY OR FIRE COULD RESULT. 1. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. 2. Purchaser/use
Resumen del contenido incluido en la página 9
WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubberlike materials. Drying in a heated basket (tumbler) may damage plastics or rubber and may be a fire hazard. 7. A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork, and area around the back of the dryer. The frequency of inspection and cleaning can best be determined from experience at each location. WARNING: The collection
Resumen del contenido incluido en la página 10
SECTION II SPECIFICATIONS AND DIMENSIONS A. SPECIFICATIONS Maximum Capacity (Dry Weight) 670 lb 303.9 kg 198.8 cm Basket Diameter 78-1/4" Basket Depth 92" 233.7 cm 7.25 cu m Basket Volume 256 cu ft Blower Motor 2 x 5 hp 2 x 3.73 kW Basket Motor 25 hp 18.7 kW Door Sill Height, Level 52" 132.1 cm Compressed Air Volume (1-way / 2-way tilt) 15/19 cfh 0.42/0.54 cmh Compressed Air Connection 1/2" F.N.P.T. S.A.F.E. Water Connection* 1" F.N.P.T. Voltage Available 208-480v / 3Ø / 3,4w / 50/60 Hz 554,400
Resumen del contenido incluido en la página 11
AD-670 1 Door Tilting/2 Door Tilting B. DIMENSIONS NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation. 7
Resumen del contenido incluido en la página 12
SECTION III INSTALLATION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrical Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Pro
Resumen del contenido incluido en la página 13
B. FRESH AIR SUPPLY REQUIREMENTS When the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the make-up air is inadequate, drying time and efficiency will be adversely affected. Ignition problems and sail switch “fluttering” problems may result, as well as premature motor failure from overheating. Air supply (make-up air) must be g
Resumen del contenido incluido en la página 14
IMPORTANT: Make-up air must be provided from a source free of dry cleaning solvent fumes. Make-up air that is contaminated by dry cleaning solvent fumes will result in irreparable damage to the motors and other dryer components. NOTE: Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY. C. EXHAUST REQUIREMENTS IMPORTANT: Each AD-670 must be individually exhausted to the outdoors. 1. General Exhaust Ductwork Information Exhaust ductwork should be designed and installed by
Resumen del contenido incluido en la página 15
IMPORTANT: Exhaust back pressure measured by a Magnehelic in the exhaust duct must be no less than 0 and must not exceed 1.0 inch (2.48 mb) of water column (W.C.). NOTE: When the exhaust ductwork passes through a wall, ceiling, or roof made of combustible materials, the opening must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening. a. Outside Ductwork Protection 1) To protect the outside end of the horizontal ductwork from the weathe
Resumen del contenido incluido en la página 16
12
Resumen del contenido incluido en la página 17
D. ELECTRICAL REQUIREMENTS It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL electrical connections, materials, and workmanship must conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Electrical Codes Parts 1 &
Resumen del contenido incluido en la página 18
WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to the dryer components due to improper voltage connections will automatically VOID THE WARRANTY. NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation. 2. Electrical Connections NOTE: A wiring diagram is included with each dryer and is located in the blueprint pocket inside the left hand side control cabinet. The main electrical input connections to the dryer are the 3-phase (3ø) po
Resumen del contenido incluido en la página 19
E. GAS REQUIREMENTS It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requirements of the National Fuel Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-
Resumen del contenido incluido en la página 20
2. Technical Gas Data a. Gas Specifications TYPE OF GAS Natural Liquid Propane Pressure @ Hi-Fire Gas Valve* 3.5 inches W.C. 8.7 mb 6.5 inches W.C. 16.17 mb Pressure @ Gauge P1* 3.5 inches W.C. 8.7 mb 6.5 inches W.C. 16.17 mb Pressure Into Internal Regulator 6.0 - 12.0 inches W.C. 14.92 mb - 29.9 mb 11.0 inches W.C. 27.4 mb Shaded areas are stated in metric equivalents * Measured at the gas valve pressure tap when the gas valve is on. b. Gas Connections Run a 2-inch gas pipe from the main ga