Resumen del contenido incluido en la página 1
CLOTHES DRYER
Technical Information
• Due to possibility of personal injury or property damage, always co ntact an authorized
technician for servicing or repair of this unit.
• Refer to Service Manual (DV456*,DV422*,DV400*) for detailed installati on, operating, testing,
troubleshooting, and disassembly instructions.
CAUTION
All safety information must be follwed as provided in Service Manual of
DV456*,DV422*,DV400*.
WARNING
To avoid risk of electrical shock, personal injury or death; disco
Resumen del contenido incluido en la página 2
ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. ERROR ITEMS AND DIAGNOSTIC CODES An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays from the following errors. Error Display Trigger Action Taken Check for: The Thermistor resistance is - Clogged lint screen. tE very low or high. - Restricted vent system. - C
Resumen del contenido incluido en la página 3
ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. TEST MODE Continuous Run Mode: 1. Press Wrinkle Prevent + Dry Level for 7 sec during Power On State (Normal User Mode) . 2. Once in Continuous Run Mode, display “CC” for 1 sec and the nu mber of Cycle for 1 sec and the remaining time for 1 sec in turns. 3. The previous cycle will restart during Continuous Run Mode until the
Resumen del contenido incluido en la página 4
ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. Data Display Mode Definition of Temperature Display Mode: - Display Mode 0 : Temperature data(Celsius) - Display Mode 1 : Average Touch Sensor data for 1 minute - Display Mode 2 : Average Temperature(Celsius) data for 1minute How to Enter: - With Power On, press AdjustUp Key + AdjsutDown Key for 7 seco nds until it sends ou
Resumen del contenido incluido en la página 5
ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. TROUBLE DIAGNOSIS - As the micom dry machine is configured of the complicate structure, there might be the service call. Below information is prepared for exact trouble diagnosis and suitable repair guide. Caution for the Repair and Replacement Please follow below instruction for the trouble diagnosis and parts replacement.
Resumen del contenido incluido en la página 6
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. No Problem What To Do • All wires are hooked up to their corresponding terminals. • Dryer is plugged in. • Blown fuse or circuit breaker. • Door switch functional...door closed. Check for error code 3 (See Table for codedefinition). 1 Will Not Start or Run • Start/Pause rotary selector dial functional. • Control Board operational. • Be
Resumen del contenido incluido en la página 7
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. No Problem What To Do If the igniter does not heat up, remove power and using an ohmmeter, check the following: • Open flame sensor The igniter does not • Open igniter 8 glow • Shorted booster coil • Open wiring • Bad motor switch ( Neutral supply) • No power from control ( L1 supply) If the igniter heats up but the main burner flame i
Resumen del contenido incluido en la página 8
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. COMPONENT TESTING PROCEDURES Component Electrical Testing (with ohmmeter) Belt Cut-off S/W - Lever open: Resistance value < 1Ω Thermistor resistance 10K Ω @ 25°C 77°F - Lever push: Resistance value : ∞ Ω Thermostat 1 resistance < 1Ω Lamp resistance 80~100 Ω (Blue & White) Thermostat 3 resistance < 1Ω - I
Resumen del contenido incluido en la página 9
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. GAS MODEL Radiant Sensor(10RS) Gas Valve(25M01A) Resistance value < 1 Ω Valve 1-2 : Resistance value about 1.2K Ω If resistance is infinite, replace Radiant sensor Valve 1-3 : Resistance value about 0.5K Ω Valve 4-5 : Resistance value about 1.2K Ω If resistance is infinity, replace Valve Igniter(101D) Resistance value 40~400 Ω If resist
Resumen del contenido incluido en la página 10
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. CN1 RY7 RY5 1. AC Power Port - Heater Relay Switch - Motor Relay Switch 2. Door Detection Sensor 3. Motor Switch Sensor Sensor Bars & temperature sensor check Sensor Bars - Disconnect harness and test Pink wire Pin 4 to Orange wire Pin 5. Approx ∞ Ω without laundry Approx 190Ω ± 10% with wet clothes Cycling Thermostat - Disconnect harn
Resumen del contenido incluido en la página 11
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. 3-WIRE system connections A. External ground connector B. Neutral grounding wire (green/yellow) C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E. ¾” (1.9 cm) UL-listed strain relief 1. Loosen or remove the center terminal block screw. 2. Connect the neutral wire (white or center wire) of the power c
Resumen del contenido incluido en la página 12
WIRING DIAGRAM WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. WIRING DIAGRAM 12
Resumen del contenido incluido en la página 13
SÈCHE-LINGE Informations techniques • En raison des risques de blessure ou de dommages matériels existants, demandez toujours à un technicien qualifié d'effectuer les opérations d'entretien ou de réparation de l'appareil. • Reportez-vous au manuel de réparation (DV456*, DV422*, DV400*) pour connaître les consignes d'installation, d'utilisation, de test, de dépannage et de démontage détaillées. ATTENTION Toutes les consignes de sécurité figurant dans le manuel de réparation de DV456*, DV422*
Resumen del contenido incluido en la página 14
ALIGNEMENTS ET RÉGLAGES AVERTISSEMENT Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf si le test nécessite sa mise sous tension. CODES D'ERREUR ET DIAGNOTICS Lorsqu'une erreur se produit, un signal sonore retentit pendant 5 secondes et l'un des messages d'erreur suivants s'affiche en continu. Affichage de Problème Vérification l'erreur Diagnostic possible : - Filtre à peluches bouché. La résistance de la thermistance tE est t
Resumen del contenido incluido en la página 15
ALIGNEMENTS ET RÉGLAGES AVERTISSEMENT Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf si le test nécessite sa mise sous tension. MODE DE TEST Mode de fonctionnement en continu : 1. Appuyez sur Wrinkle Prevent (Anti-froissage) et Dry Level (Niveau de séchage) pendant 7 secondes avec l'appareil sous tension (mode d'utilisation normale). 2. Une fois en mode de fonctionnement en continu, « CC », le numéro du cycle et le temps restan
Resumen del contenido incluido en la página 16
ALIGNEMENTS ET RÉGLAGES AVERTISSEMENT Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf si le test nécessite sa mise sous tension. Mode version logicielle Définition du mode version logicielle : - Permet de retrouver la version logicielle Pour sélectionner ce mode : - En mode de réparation, appuyez sur Temp jusqu’à l’émission d’un signal sonore Exemple : pour « U0 05 », U0 signifie version principale « U0 » et 05 signifie version
Resumen del contenido incluido en la página 17
ALIGNEMENTS ET RÉGLAGES AVERTISSEMENT Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf si le test nécessite sa mise sous tension. DIAGNOSTIC DES PROBLÈMES - Le micom du sèche-linge est configuré pour une structure complexe, c'est pourquoi il est conseillé de contacter le service après-vente. Les informations suivantes répondent à un diagnostic précis et constituent un guide de réparation adapté. Consignes à respecter pendant
Resumen del contenido incluido en la página 18
DÉPANNAGE AVERTISSEMENT Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf si le test nécessite sa mise sous tension. N° Problème Procédure à suivre • Tous les câbles sont branchés sur les bornes correspondantes. • Le sèche-linge est branché. • Le fusible est grillé ou le disjoncteur est déclenché. • Interrupteur du hublot fonctionnel...hublot fermé. Vérifiez le code d'erreur 3 (reportez-vous au tableau pour la définition des codes
Resumen del contenido incluido en la página 19
DÉPANNAGE AVERTISSEMENT Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf si le test nécessite sa mise sous tension. N° Problème Procédure à suivre Si l'allumeur ne chauffe pas, coupez l'alimentation et à l'aide d'un ohmmètre, vérifiez les points suivants : • Détecteur de flamme coupé • Allumeur coupé L'allumeur ne 8 s'allume pas. • Survolteur court-circuité • Câblage coupé • Commutateur de moteur défectueux (courant neutre)
Resumen del contenido incluido en la página 20
DÉPANNAGE AVERTISSEMENT Afin d'éviter tout risque d'électrocution légère ou mortelle, débranchez le sèche-linge avant de le réparer, sauf si le test nécessite sa mise sous tension. PROCÉDURES DE TEST DES COMPOSANTS Test des composants électriques (avec ohmmètre) Commutateur d'arrêt de la courroie - Manette ouverte : valeur ohmique < 1 Ω Résistance de la thermistance 10 KΩ @ 25°C (77°F) - Manette actionnée : valeur ohmique : ∞ Ω Résistance du thermostat 1 < 1 Ω Résistance de la la