Resumen del contenido incluido en la página 1
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 1
INSTRUCTION MANUAL
Automatic Blood Pressure Monitor
with Two Cuffs
Model 7300REL
ENGLISH ESPAÑOL
Resumen del contenido incluido en la página 2
HEM-7300-WM_A_M_A-E_SP_r2.qxp 8/22/11 4:48 PM Page 2 TABLE OF CONTENTS Before Using the Monitor Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Operating the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Risk of Electrical Shock . . . . . . . . . . . . . . . . . . . . . . . . .
Resumen del contenido incluido en la página 3
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 3 Before Using the Monitor INTRODUCTION ® ® Thank you for purchasing the ReliOn 7300REL IntelliSense Automatic Blood Pressure Monitor. Fill in for future reference. DATE PURCHASED: __________________ SERIAL NUMBER: ____________________ • Staple your purchase receipt here • Register your product on-line at www.register-omron.com Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the mon
Resumen del contenido incluido en la página 4
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 4 SAFETY INFORMATION INTENDED USE This product is designed to measure the blood pressure and pulse rate in adult patient population, following the instructions in this manual. It is mainly designed for general home use. To assure the correct use of the product, basic safety measures should always be followed including the warnings and cautions listed in this instruction manual. SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL Indicates a potenti
Resumen del contenido incluido en la página 5
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 5 SAFETY INFORMATION OPERATING THE DEVICE (continued) The monitor is not intended to be a diagnostic device. If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately. Read all of the information in the instruction manual and any other literature in the box before operating the unit. This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do
Resumen del contenido incluido en la página 6
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 6 SAFETY INFORMATION RISK OF ELECTRICAL SHOCK Do not plug or unplug the power cord into the electrical outlet with wet hands. Do not overload power outlets. Plug the device into the appropriate voltage outlet. CARE AND MAINTENANCE Do not subject the monitor to strong shocks, such as dropping the unit on the floor. Do not submerge the device or any of the components in water. Store the device and the components in a clean, safe location. Changes
Resumen del contenido incluido en la página 7
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 7 BEFORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations: 1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure. Avoid taking measurements during stressful times. 3. Measurements should be taken in a quiet place. 4. Remove tight-fitting clothing from your arm. 5. Sit
Resumen del contenido incluido en la página 8
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 8 Operating Instructions KNOW YOUR UNIT Main Unit: Display Air Jack User ID Selection Switch ( ) AC Adapter Jack Memory Button ( ) Start/Stop Button Battery Compartment 8
Resumen del contenido incluido en la página 9
HEM-7300-WM_A_M_A-E_SP_r4.qxp 8/24/11 11:36 AM Page 9 KNOW YOUR UNIT Components: Arm Cuffs Air Tube Air Tube Air Plug Air Plug (Connects to Air Jack) (Connects to Air Jack) Standard Arm Cuff Large Arm Cuff Housing Cord AC Adapter Four “AAA” Batteries INSTRUCTION MANUAL Automatic Blood Pressure Monitor with Two Cuffs Model 7300REL Quick Start Storage Case Guide Instruction Manual Log Book Cuff Guide 9 ENGLISH ESPAÑOL
Resumen del contenido incluido en la página 10
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 10 UNIT DISPLAY Systolic Blood Pressure Diastolic Blood Pressure Heartbeat Symbol/ Medication Symbol Hypertension Indicator Pulse Display Deflation Symbol Memory Symbol Date/Time Display Average Value Symbol Low Battery Indicator User ID Symbol (A or B) Movement Error Symbol Irregular Heartbeat Symbol 10
Resumen del contenido incluido en la página 11
HEM-7300-WM_A_M_A-E_SP_r2.qxp 8/22/11 4:48 PM Page 11 DISPLAY SYMBOLS IRREGULAR HEARTBEAT SYMBOL() When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values. An irregular heartbeat rhythm is defined N Normal H ormal Hear eartb tbeat eat as a rhythm that varies by less than 25% Pulse from the average rhythm or 25% more Blood pressure than the average rhythm detected while the
Resumen del contenido incluido en la página 12
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 12 DISPLAY SYMBOLS HEARTBEAT SYMBOL/HYPERTENSION INDICATOR() TAKING A MEASUREMENT The Heartbeat Symbol ( ) flashes on the display during the measurement. The Heartbeat Symbol ( ) flashes at every heartbeat. When the measurement is complete, the Heartbeat Symbol ( ) flashes on the display with your blood pressure and pulse rate if the reading is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value. USI
Resumen del contenido incluido en la página 13
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 13 DISPLAY SYMBOLS Internationally recognized guidelines for upper limit of normal home blood pressure readings are as follows: Home Guideline for Upper Limit of Normal BP* Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg This is a general guideline because blood pressure depends on age and morbidity. A lower home blood pressure goal may be recommended for certain patients, including diabetic patients, pregnant women, and patien
Resumen del contenido incluido en la página 14
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 14 USING THE AC ADAPTER IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS - DANGER - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, CAREFULLY FOLLOW THESE INSTRUCTIONS. For connection to a power supply not in the U.S.A., use an attachment plug adapter of the proper configuration for the power outlet. The power unit (AC Adapter) is intended to be correctly oriented in a vertical or floor mount position. NOTES: • Use only the authorized AC Ada
Resumen del contenido incluido en la página 15
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 15 USING THE AC ADAPTER TO CONNECT THE AC ADAPTER ① Insert the AC Adapter Plug into the Housing AC Adapter Jack on the right side of the monitor as illustrated. ② Plug the AC Adapter into a 120V AC outlet (60 cycles). Cord TO DISCONNECT THE AC ADAPTER ① Hold and pull the Housing to remove the AC Adapter from the electrical outlet. Do not remove by pulling the cord. ② Remove the AC Adapter plug from the monitor. WARNING Do not plug or unplug the
Resumen del contenido incluido en la página 16
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 16 BATTERY INSTALLATION 1. Press the ▼ indicator on the battery cover and slide the cover off in the direction of the arrow. Battery Cover 2. Install 4 “AAA” size batteries so the + (positive) and – (negative) polarities match the polarities of the battery compartment as indicated. 3. Replace the battery cover. 16
Resumen del contenido incluido en la página 17
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 17 BATTERY INSTALLATION BATTERY REPLACEMENT Low Battery Indicator When the Low Battery Indicator appears on the display screen, turn the monitor off and remove all the batteries. Replace with four new batteries at the same time. WARNING If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately. NOTES: • Turn the unit off before replacing the batteries. If the batteries are removed whi
Resumen del contenido incluido en la página 18
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 18 SETTING THE DATE AND TIME Set the monitor to the current date and time before taking a measurement for the first time. If the date and time are not set correctly, the measurement values stored in the memory and the average values may not be correct. If the date and time are not set, “-:--” appears during or after measurement. 1. TO START THE SETTING Press and hold the USER ID Selection Switch ( ) to adjust the date and time. The year flashes
Resumen del contenido incluido en la página 19
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 19 SETTING THE DATE AND TIME 2. SETTING THE YEAR The year can be set between 2011 and 2040. When the display reaches 2040, it will return to 2011. Press the Memory button ( ) to advance by one year increments. Press the User ID Selection Switch ( ) to set the current year. The month flashes on the display. NOTE: Press and hold the Memory button ( ) to advance the date and time values faster. 3. SETTING THE MONTH Press the Memory button ( ) to
Resumen del contenido incluido en la página 20
HEM-7300-WM_A_M_A-E_SP.qxp 8/19/11 5:29 PM Page 20 SETTING THE DATE AND TIME 4. SETTING THE DAY Press the Memory button ( ) to advance by one day increments. Press the USER ID Selection Switch ( ) to set the current day. The hour flashes on the display. 5. SETTING THE HOUR The time is set using AM or PM. Press the Memory button ( ) to advance by one hour increments. Press the USER ID Selection Switch ( ) to set the current hour. The minute flashes on the display. 6. SETTING THE MINUTE Press