Resumen del contenido incluido en la página 1
GE Fanuc Automation
Programmable Control Products
PANELWARE™ MMI Application Manual
for GE Fanuc Genius™ Protocol
User's Manual
GFK - 1115 June 1995
Resumen del contenido incluido en la página 2
GFL-002 Warnings, Cautions, and Notes as Used in this Publication Warning Warning notices are used in this publication to emphasize that hazardous voltages, currents, temperatures, or other conditions that could cause personal injury exist in this equipment or may be associated with its use. In situations where inattention could cause either personal injury or damage to equipment, a Warning notice is used. Caution Caution notices are used where equipment might be damaged if care is not taken. No
Resumen del contenido incluido en la página 3
Preface This manual provides a quick guide to installing and operating PANELWARE™ Panels, describes configuration techniques, and outlines general use of the PANELWARE Configuration Software (PCS) with GE Fanuc Genius Protocol. Some of the products mentioned or illustrated in this manual may not be released when this document is published. Please do not rely on any references made to these units. Your local GE Fanuc distributor will inform you of any new product releases. Content of This Manual
Resumen del contenido incluido en la página 4
Preface Related Publications PANELWARE Manuals GFK-0848 PANELWARE™ Hardware Installation User's Manual Describes the PANELWARE Operator Panels and contains technical data, hardware installation instructions, and the general information required for putting the Panels into operation. GFK-0849 PANELWARE™ Configuration Software Reference Manual Describes the PANELWARE Configuration Software and provides the program setups for Panels that are equipped with a programmable controller. GFK-0850 PANELWA
Resumen del contenido incluido en la página 5
Preface GFK-0852 Series 90™ PLC Serial Communications User's Manual This manual describes serial communications products for the Series 90 Programmable Logic Controller. Information is provided to implement a serial communications link between the Series 90 PLC, a host computer, peripheral device, or another PLC. GFK-0898 Series 90-30 Programmable Controller I/O Module Specifications Describes the discrete and analog I/O modules for the GE Fanuc Series 90-30 PLC. Contains descriptions of each I/
Resumen del contenido incluido en la página 6
Contents Chapter 1 Overview ............................................................................................................... 1-1 PANELWARE Configuration Software..............................................................................1-2 Hardware and Software Requirements................................................................................1-3 PLC Requirements...........................................................................................................
Resumen del contenido incluido en la página 7
Contents Section 5 Creating a New Project.......................................................................3-10 Section 6 Defining Connections..........................................................................3-13 Connection to a GE Fanuc PLC via Genius ...................................................................... 3-14 Internal Connection .......................................................................................................... 3-17 Genius Internal Connection
Resumen del contenido incluido en la página 8
Contents Elements of the Connection List .........................................................................................5-3 Using Function Keys in the Connection List........................................................................5-3 Overview.....................................................................................................................5-3 Editing/Inserting Connections.......................................................................................5-4
Resumen del contenido incluido en la página 9
Contents Creating a Project ............................................................................................................ 6-16 Preparing a Concept................................................................................................... 6-17 Creating a New Project .............................................................................................. 6-18 Selecting the Connections......................................................................................
Resumen del contenido incluido en la página 10
Overview Chapter 1 This chapter provides a short overview/description of the PANELWARE Configuration Software (PCS) and outlines the requirements for PCS operation with the PC and PLC. It includes the following information: ■ PANELWARE Configuration Software (PCS) ............................................................1-2 ■ Hardware and Software Requirements ........................................................................1-3 ■ PLC Requirements........................................
Resumen del contenido incluido en la página 11
1 PANELWARE Configuration Software PANELWARE Configuration Software allows complex projects to be created, using easy-to- follow, menu-controlled instructions. These projects are actually programs that are transferred to a Panel and started there via a Panel power-on or Reset. The PCS-created Panel program (project) then takes over communication with the PLC and performs the following: ■ Reads data from the PLC and displays it on the screen in the specified format (values, text, bar-graphs, grap
Resumen del contenido incluido en la página 12
1 Hardware and Software Requirements PCS is delivered on two 3½-inch disks in 2DD (720K) format and on one 5¼-inch disk in 2S/HD (1.2M) format. The diskette(s) you use to install the PCS depends on your PC configuration. Description Catalog Number PANELWARE Configuration Software IC641SWP950 (includes cable assembly) Before starting the software installation, make sure the following requirements are met: ■ Complete IBM PC compatibility (processor types: 80286 and higher) ■ IBM compatible monochr
Resumen del contenido incluido en la página 13
1 PLC Requirements To communicate with the C400 Genius Panel Controller, the PLC must meet the following requirements: ■ Series 90-70 PLC ❏ Genius Bus Controller (GBC), IC697BEM731 ■ Series 90-30 PLC ❏ Genius Communications Module (GCM), IC693CMM301 ❏ Enhanced Genius Communications Module (GCM+), IC693CMM302 ❏ Genius Bus Controller, IC693BEM331 ■ Series Six ❏ Genius Bus Controller with diagnostics, IC660CBB902 ❏ Genius Bus Controller without diagnostics, IC660CBB903 ■ Series Five ❏ Genius Bus Co
Resumen del contenido incluido en la página 14
1 Document Conventions Key Symbols All keys used to operate PCS are shown in bold in this manual: Table 1 - 2. Key Symbols Key German English Description Cursor up ↑↑ ↑ ↑ ↓↓ ↓ ↓ Cursor down Cursor left ←← ← ← →→ → → Cursor right Enter (Return) ↵↵ ↵ ↵ Bild↑ ↑ PgUp Cursor one page up Bild↓ ↓ PgDn Cursor one page down Einfg Ins Switches between insert and overwrite modes The character in the cursor position is deleted Entf Del Esc Esc Exits from the current function; exits the editor or a menu Spa
Resumen del contenido incluido en la página 15
C400 Panel Controller Hardware Chapter 2 This chapter describes the C400 PANELWARE Panel Controller (IC750CTR400), its connections (interfaces) and all operational elements for which hardware must be configured on the modular Panel. The following sections of information are included: ■ General Information ...................................................................................................2-2 ❏ Power Requirement.......................................................................
Resumen del contenido incluido en la página 16
2 General Information Power Requirement 24 VDC power must be supplied to the PANELWARE Controller unit. The Controller, in turn, supplies the Keyblock and Display modules with power. When estimating the total 24 VDC power consumption for a system, add up the 24 VDC power supply requirements for all of the PANELWARE components being used, then add an additional 30% to allow for power on surge currents. Refer to the PANELWARE™ Hardware Installation User’s Guide (GFK-0848) for details on displays a
Resumen del contenido incluido en la página 17
GENIUS 2 Genius Panel Controller (C400) Specifications a45517 SHLD OUT SHLD IN 7.165" X2 X1 (182mm) 2.165" 7.165" (55mm) (182mm) Figure 2 - 1. Genius Panel Controller (C400) Table 2 - 1. Specifications for Genius Panel Controller (C400) Technical Data IF0: RS-232 (not galvanically isolated) Interfaces Genius: (isolated) Programming PANELWARE Configuration Software Power supply 24 VDC (min. 18 VDC, max. 30 VDC) YES with battery installed (non-volatile) Real-time clock Connection of .... 1 Di
Resumen del contenido incluido en la página 18
2 Table 2 - 1. - Continued Shock conforms to IEC 68-2-27 2 15g equivalent, 150 m/sec , 11 msec, 3 axes (positive and negative) Vibration conforms to IEC 68-2-6 1g equivalent, 10-58 Hz; 0.075 mm 2 58-150 Hz; 9.8m/sec 20 cycles per axis Processor Motorola 68302 @ 16 MHz 24 VDC power 185 mA, 24 VDC requirements 260 mA, 18 VDC (minimum power voltage) (typical) 150 mA, 30 VDC (maximum power voltage) NEMA 12 and IP54 when properly mounted in a Panel Sealing Noise immunity conforms to IEC 801.2;
Resumen del contenido incluido en la página 19
2 Overview of Connections and Operational Elements a45516 1 2 9 8 3 7 6 4 5 Figure 2 - 2. Genius Panel Controller (C400) Elements/Connections 1. Display Module Connector (ribbon 6. Mode Switch - Operating Mode cable) 7. Cover for Lithium Battery 2. 24 VDC Power Supply Connector 8. Device Number Switches 3. IF0: RS-232 (to PC), labeled 0 9. Reset Button 4. Genius Bus Connector 5. Keyblock Module Connector GFK-1115 Chapter 2 C400 Panel Controller Hardware 2 - 5
Resumen del contenido incluido en la página 20
2 24 VDC Power Supply (item 2, Figure 2-2) Pin Description + +24 V - 0 V Ground Ground The pins are to be connected using as short a cable as is possible. If the Panel is mounted in a cabinet, the connecting cable should be as short as possible. IF0 - RS-232, Non-isolated (item 3, Figure 2-2) Pin Description 1NC 2 RxD Receive Data (Input) 3 TxD Transmit Data (Output) 4 + 5 V Power Supply 9 pin D-Type (M) (200 mA available to user) 5 GND Signal Ground LED Meaning 6NC TxD Send data over interface