Resumen del contenido incluido en la página 1
®
Culligan
®
Iron-Cleer Plus
Automatic
Water Filter
Owners Guide
Resumen del contenido incluido en la página 2
Thank You And Welcome To Your New World Of Better Living With Culligan Water. This system and its installation must comply with state and local regulations. The System is ONLY to be supplied with cold water. ® ® The Culligan Iron Cleer water filter has been tested and certified by WQA against WQA S-200 for the effective reduction of iron up to 1,400 gallons for 10” units and 2,000 gallons for 12” units. Do not use with water that is microbiologically unsafe or of unknown quality without ade
Resumen del contenido incluido en la página 3
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Table of Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Contents Operating Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Familiarization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Programming. . . . . . . . . . .
Resumen del contenido incluido en la página 4
This page intentionally left blank. iv
Resumen del contenido incluido en la página 5
® ® Culligan Iron Cleer Plus Filters Specifications 10” Iron Cleer 12” Iron Cleer 1” 5-cycle reinforced 1” 5-cycle reinforced Control Valve thermoplastic thermoplastic Timer Electro-mechanical Electro-mechanical Overall Conditioner Height 67” 65” Media Tank Dimensions (D x H) 2 ea. 10” x 54” tanks 2 ea. 12” x 52” tanks Filter Media Type 1.0 cu. ft. birm 1.5 cu. ft. birm Underbedding G-50 35 lbs. 35 lbs. Cullsan U 25 lbs. 25 lbs. 1 Capacity 1400 gallons 2000 gallons 2 Freeboard 21” 18” Max. C
Resumen del contenido incluido en la página 6
Introduction Operation Step 1. Aeration Operation Service Cycle In the service cycle, raw water enters the inlet port of the aeration tank and is directed through the inlet diffuser. The oxidation process begins when the water passes through the inlet diffuser and cascades through a head of air. This air/ water contact oxidizes the iron, manganese, hydrogen sulfide in the water. The water is directed toward the bottom of the tank and travels through the pick- up tube. It then passes through t
Resumen del contenido incluido en la página 7
Shuttle Valve Operation Introduction In the service position, water pressure holds the shuttle valve piston in the closed position, trapping (cont.) the airhead in the aeration tank and closes the air recharge inlet port and drain port. During air recharge cycle, air pressure is greater than the water pressure and forces the shuttle valve piston in the open piston. The shuttle valve has an internal pressure relief valve that will relieve pressure (greater than 100 psi) that may build up in
Resumen del contenido incluido en la página 8
The concentration limits listed below reflect the maximum individual limit that each contaminant was Operating tested for separately without any interference of other contaminants in the influent water. Conditions In reality, however, we know that these contaminants may be present in combination which may limit the filter’s ability to remove these contaminants in higher concentrations. In some cases, individual sellers of this equipment have had success removing higher concentrations of cont
Resumen del contenido incluido en la página 9
Power Loss Familiarization ® The AccuSoft circuit board is equipped with a Hi-Cap Capacitor and EEPROM memory chip. The capacitor is capable of maintaining the time, for at least two days, in the event of a power outage. The EEPROM ensures that the individual programming parameters of your filter are not lost. If the power outage lasts long enough to drain the Hi-Cap Capacitor, the control will flash “12:00 PM” when power is returned to the control. The unit will continue to keep time from th
Resumen del contenido incluido en la página 10
Familiarization Modes of Operation (cont.) Manual Regeneration Pressing and holding the regen button for 3 seconds will initiate an immediate regeneration. The beeper is to give one beep at the start of manual regeneration (when the motor starts to turn). In delay mode, pressing and releasing the regen button will light the regen icon for regeneration to occur at the set delay time. Pressing and releasing the regen button again will turn off the regen icon. Power Loss ® The AccuSoft circ
Resumen del contenido incluido en la página 11
® ® The Culligan AccuSoft Plus circuit board controls all Programming of the filter functions. These settings are programmed at the time of installation. The following is a list of all the microprocessor functions, in the event that any of % the settings need to be adjusted. Display Icons The display is to be backlit and have the icons as shown below. Custom LCD Display Six standard 12-segment alpha-numeric characters, a decimal separating the first and second character, a colon separating
Resumen del contenido incluido en la página 12
• Time of Regeneration - This setting is used to program the Programming time at which a regeneration is to occur in the delay mode, or in (cont.) immediate mode with time clock backup on. The display will first show “tor” for two seconds. After “tor” is shown the display will then show the default of 2:00 AM (or the current programmed time of regeneration if already Time Flashing set). The time can be adjusted in 30 minute increments by pressing the “Up” or “Down” keys. Pressing the “
Resumen del contenido incluido en la página 13
• Filter Media Life (Change Media) - This setting is used Programming in Filter Mode ONLY with flow meter attached. It enables or (cont.) disables an alarm code (“CHANGE MEDIA”) that indicates the end of life for the filter media. The display will show “LIFE” in the left most characters and toggle between “Y” and “N” in the right most character with the “+” and “-“ keys. If “NO” is selected, the alarm is disabled and the ‘Total Capacity’ setting will be treated as it is in Flow Meter M
Resumen del contenido incluido en la página 14
The statistical functions are reached by pressing the “Information” key. Repetitive presses of the Statistic “Information” key will cycle through the standard statistics mode until cycled back to time of day Functions display. Once either of the Information menus is entered the information shown for each display is outlined below: • Flow Rate - This display will only show if the flow meter is attached to the control. The display shall show the current flow rate of the water passing throu
Resumen del contenido incluido en la página 15
Normally, all water except outside lines passes through the water conditioner. There are times when When and ® the water conditioner should be bypassed, using the Cul-Flo-Valv Bypass, or a 3-way bypass valve. How to You should bypass: Bypass Your Water 1. If lines to outside faucets do not bypass the water conditioner, and you do not want to waste Conditioner conditioned water on lawn sprinkling or other outside uses. 2. If you are going away on vacation and want to save salt by not havin
Resumen del contenido incluido en la página 16
When and Aeration Tank Bypass Valve Aeration Tank – Bypass Valve Operation How to Bypass Your Bypass Operation Normal Operation Water Filter “Treated” Water Supply Water Supply Water Supply Water (cont.) Exits Enters Exits Enters Diagnostic Mode Shut-Off Mode Supply Water Supply Water is Shut Supply Water No Water Exits Enters Exits Off From The House and The Valve 12
Resumen del contenido incluido en la página 17
If you unexpectedly experience problem water, make these simple checks before calling your Culligan Things to dealer. One of the following conditions may be the reason for your interruption of service. Check Before You Call for Important Service If any of the following conditions is found, the water filter should be manually recharged according to instructions on page 5 after you have corrected the problem. Power Supply Check your power supply cord. Is it plugged fully into the electric o
Resumen del contenido incluido en la página 18
The Culligan Iron Cleer water filter has been designed to provide a good, consistent service life. Recommended Because of the nature of problem water, we recommend that the local Culligan dealer provide regular Preventative maintenance/service contracts for the proper operation of your systems. The water filter service Maintenance begins with a multi point inspection of your water filter system in an effort to uncover any and all problems that may exist. Listed below is a recommended l
Resumen del contenido incluido en la página 19
Troubleshooting Complaint Problem Cause Solution Guide Iron bleed- A. Inadequate 1. Plugged drain line flow 1. Call your Culligan dealer for through or backwash of filter control service. staining. 2. Insufficient water supply from 2. Check for minimum specified well. flow and pressure requirements of filter system. 3. Plugged aeration tank inlet 3. Call your Culligan dealer for diffuser or pick-up tube. service. 4. Media bed fouled. 4. Call your Culligan dealer for service. B. Fails to 1.
Resumen del contenido incluido en la página 20
Troubleshooting Complaint Problem Cause Solution Guide (cont.) Water leaking A. Dirt lodged under 1. Pressure has exceeded 1. Call your Culligan dealer from relief seat of valve. rating on relief valve and for service. valve. caused valve to open B. Faulty or defective 1. Call your Culligan dealer relief valve for service. Water is A. This can be 1. Water supply has been 1. This natural phenomenon effervescent expected when water naturally aerated under well will typically dissipate to the