Resumen del contenido incluido en la página 1
®
POWDER
BUNN
™
AUTO FILL
For ULTRA-2
OPERATING & SERVICE MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
www.bunnomatic.com
29793.0001B 08/02 ©2002 Bunn-O-Matic Corporation
Resumen del contenido incluido en la página 2
INTRODUCTION This equipment supplies a liquid mix to the hoppers on the ULTRA-2 dispenser. It is for indoor use only on a sturdy counter or shelf. BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor. 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years parts and 1 year labor. 4)
Resumen del contenido incluido en la página 3
INITIAL SET-UP 1. Loosen auger motor cover screws. 2. Remove rear plastic plug from trim strip between hopper drip trays. 3. Install support rod into hole in trim strip. 4. Place PAF platform assembly on top of motor covers. 5. Tighten support rod from top of platform. 6. Retighten motor cover screws. 7. Plug RCA cord into ULTRA base unit. 8. Install hopper seal and press firmly into place on the flange of the cooling drum. 9. Align the auger shaft with the flat fin of the auger. Push the augers
Resumen del contenido incluido en la página 4
OPERATING INSTRUCTIONS 8. If the Powder Auto-Fill fails to fill the ULTRA hopper 1. On the Ultra touch pad, make the following settings: a) POWER- "ON" in 5 minutes, the following will occur: a) The Powder Auto-Fill will stop dispensing prod- b) DAY/NIGHT- "DAY" uct. 2. Pull the Powder Auto-Fill fully forward on its sup- port rails and open the door. b) The door lamp will flash 4 times about every 2 seconds. 3. Fill the Powder Auto-Fill product hopper as follows: a) Pull the slide gate closed on
Resumen del contenido incluido en la página 5
ADJUSTMENTS When using the Powder Auto-Fill with a new powdered granita mix, follow the procedure outlined below to adjust the Powder Auto-Fill to produce the correct recipe. 1. Determine the mix ratio of powdered granita mix. i) Remove the hole plug on the whipper panel. Convert the recipe so that it is expressed in terms Using a screwdriver, set potentiometer to approxi- of weight units [grams (g), dry ounces (oz), or mately mid range. pounds (lbs)] of powdered granita mix to fluid j) Remove t
Resumen del contenido incluido en la página 6
CLEANING RECOMMENDED DAILY CLEANING AND MAINTENANCE TIPS This should be done in conjunction with the recommended weekly cleaning of your ULTRA-2 machine. Removing and cleaning the whipper chamber (once a day): 1. Open the cabinet door. 2. Pull the mixing chamber out of the whipper cham- ber. 3. Twist the whipper chamber clockwise and pull it off the whipper chamber receptacle. Mixing Chamber 4. Pull the frother off the motor shaft. Notice the flat keyway on the shaft and the matching keyway insi
Resumen del contenido incluido en la página 7
FAULT LIST Door Lamp Fault ON Normal operation - Powder Auto-Fill ready to dispense Flashes ON/OFF at 50% duty cycle Low product level in Powder Auto-Fill hopper Two flashes about every 2 seconds ULTRA/Powder Auto-Fill probe circuit open Three flashes about every 2 seconds Powder Auto-Fill hopper not in place Four flashes about every 2 seconds ULTRA refill exceeded 5 minutes OFF Door not closed 29793.1 021202 7
Resumen del contenido incluido en la página 8
TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. • All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of terminals or the appl
Resumen del contenido incluido en la página 9
TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Product level in ULTRA is lower than 1. Powder Auto-Fill not pulled com- 1. Check that the Powder Auto-Fill is level Probe - ULTRA running; Pow- pletely forward. pulled completely forward until the der Auto-Fill door lamp flashes two guide rails roll into the indented po- times sition. 2. ULTRA level probe misaligned. 2. Position the ULTRA level probe so that it is located in the notch of the ULTRA hopper and touching the con- tact protruding
Resumen del contenido incluido en la página 10
TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Powder Auto-Fill will not dispense 1. No water Water lines and valves to the dis- product penser must be open and free of obstructions. 2. No power or incorrect voltage to Check that the power cord is con- the dispenser. nected to the ULTRA dispenser and for voltage from the ULTRA dis- penser. 3. Dispense Solenoid Valve Refer to Service- Dispense Solenoid Valve for testing procedures. See page 32 4. Control Board and Probe Refer to Service- C
Resumen del contenido incluido en la página 11
TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Product overflows ULTRA hopper 1. Control Board and Probe Refer to Service- Control Board and Probe for testing procedures. See page 18 2. Dispense Solenoid Valve Refer to Service- Dispense Solenoid Valve for testing procedures. See page 32 Weak product 1. Whipper Motor Refer to Service- Whipper Motor for testing procedures. See page 16 2. Frother Refer to Service- Frother for testing procedures. See page 15 3. Dispense Solenoid Valve Refer t
Resumen del contenido incluido en la página 12
SERVICE This section provides procedures for testing and replacing various major components used in this dis- penser should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electrical equipment should be performed only by qualified ser- vice personnel. The dispenser should be unplugged when servicing, except when electrical tests are re- quired and the test procedure specifically states to pl
Resumen del contenido incluido en la página 13
SERVICE (cont.) AUGER DRIVE COMPONENTS 12. Rinse and dry each item thoroughly. 13. Check for damaged or broken components, re- place any if necessary and reassemble hopper assembly. 14. Install hopper assembly in the dispenser by sliding hopper assy on the hopper support plate (12) until the hopper base (9) seats firmly behind the re- tainer plates (16) on the hopper support plate (12). 1 2 3 4 5 6 13 7 P1922 FIG. 2 AUGER DRIVE COMPONENTS 14 8 9 Location 20 10 The auger drive components are lo
Resumen del contenido incluido en la página 14
SERVICE (cont.) AUGER DRIVE MOTOR Removal and Replacement: 1. Remove hopper assembly and set aside for reas- sembly. 2. Remove six #8-32 screws securing the rear cover and remove the rear cover. 3. Remove the four #8-32 screws located inside the dispenser housing on the lower right front of the auger motor mounting panel, securing the auger motor mounting bracket and auger motor to the rear of the auger motor mounting panel. 4 Disconnect the wires from the auger drive motor. 5. Remove the auger
Resumen del contenido incluido en la página 15
SERVICE (cont.) FROTHER AND MIXING/WHIPPER CHAMBER 10. Slide whipper chamber receptacle with seal (6) and O-ring (4) on to the motor shaft. 11. Rotate the receptacle with seal (6) counterclock- wise until it snaps into place on the motor mounting nuts (7). 12. Push frother (5) onto the motor shaft, making sure the flat in the frother (5) lines up with the flat on the motor shaft. 13. Install whipper chamber (3) on the whipper cham- ber receptacle (6) by twisting counterclockwise until tabs on th
Resumen del contenido incluido en la página 16
SERVICE (cont.) WHIPPER MOTOR Removal and Replacement: 1. Disconnect the dispenser from the power source. 2. Open the dispenser door and remove the hopper assembly out the front of the dispenser. 3. Remove the four #8-32 screws securing the hopper support panel to the auger motor mounting panel and the whipper motor mounting panel. 4. Slowly lift the hopper support panel up and discon- nect the red/black and green wires from the hopper switch. 5. Pull the mixing chamber out of the whipper cham-
Resumen del contenido incluido en la página 17
SERVICE (cont.) 21. Install dispense tip into the bottom of the whipper WHIPPER MOTOR (cont.) chamber. 13. Slide the slinger onto the motor shaft flush against 22. Slip the mixing chamber onto the mixing chamber the front panel. water inlet tube far enough so the mixing chamber 14. Wash whipper chamber components in a mild will seat inside the whipper chamber. solution of dish detergent using a bristle brush. 23. Install hopper assembly in the dispenser by sliding 15. Rinse thoroughly and allow
Resumen del contenido incluido en la página 18
8. Select the "OFF" position of the main power switch SERVICE (cont.) and disconnect the dispenser from the power source. CONTROL BOARD and LEVEL PROBE If voltage is present as described, proceed to #9. If voltage is not present as described refer to the wiring diagram and check the dispenser wiring harness. 9. Reconnect the four pin connector to the control board (J7). 10. Disconnect the twelve pin connector (J1) from the control board. 11. Measure the resistance between pins 8 & 12 of the twel
Resumen del contenido incluido en la página 19
SERVICE (cont.) CONTROL BOARD and LEVEL PROBE (cont.) If voltage is present as described, proceed to #12. If voltage is not present as described, replace the photo Test Procedure: transistor. Low Product Detect 1. Disconnect the dispenser from the power source. 12. Check the voltage across pins 1 (positive) & 3 2. Disconnect the twelve pin connector (J1) from the (negative) of the four pin connector on the control control board. board with a voltmeter. Remove the hopper from 3. Check the voltage
Resumen del contenido incluido en la página 20
SERVICE (cont.) CONTROL BOARD and LEVEL PROBE (cont.) Removal and Replacement: 1. Disconnect the dispenser from the power source. 2. Remove the two plugs (J1 and J7) from the main J7 wiring harness, the potentiometer plug (J3), the photo transistor plug (J6), and the photo LED plug J1 J3 (J2) from the control board. 3. Remove the four #6-32 keps nuts securing the control board to the hopper motor mounting panel. 4. Remove the control board. 5. Remove the four spacers from the old control board a