Resumen del contenido incluido en la página 1
www.zephyronline.com
Plane
APN-M90ABX
APN-M90AWX
RANGE HOOD - Installation instructions
Resumen del contenido incluido en la página 2
www.zephyronline.com HOTTE PER CUISINE - Notice d’utilisation...Pag. 21 CAMPANA EXTRACTORA - Manual de utilización...Pag. 41 CAPPA ASPIRANTE - istruzioni per l’uso...Pag. 61 - 2 -
Resumen del contenido incluido en la página 3
SAFETY INSTRUCTIONS..................................................................................................pag. 4 LIST OF MATERIALS...........................................................................................................pag. 7 DUCTING CALCULATION SHEETS...............................................................................pag. 8 HOOD SPECIFICATION.....................................................................................................pag. 9 INSTALL
Resumen del contenido incluido en la página 4
www.zephyronline.com IMPORTANT SAFETY INSTRUCTIONS FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. Take care when using cleaning agents or detergents. Suitable for use in household cooking area WARNING - To reduce the
Resumen del contenido incluido en la página 5
settings. B. Always turn hood ON when cooking at high heat or when fl ambeing foods ( i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè ). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or fi lter. D. Use proper pan size. Always use cookware appropriate for the size of the surface element. E. Keep fan, fi lters and grease laden surface clean. F. Use high range setting on range only when necessary.Heat oil slowly on low to medium settin
Resumen del contenido incluido en la página 6
www.zephyronline.com through the fl ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. D. Ducte
Resumen del contenido incluido en la página 7
Duct Cover Bracket Duct Covers Control Glass Electrical Junction Box Range Hood Body Light Bulbs Decorative Mesh Filters - 7 - List of Materials
Resumen del contenido incluido en la página 8
www.zephyronline.com Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet. - 8 - Ducting Calculation Sheet
Resumen del contenido incluido en la página 9
front of hood side of hood top of hood - 9 - Hood Specifi cations
Resumen del contenido incluido en la página 10
www.zephyronline.com The following instructions are for installing the internal blower. CAUTION: To reduce the risk of fi re and electric shock, install this range- hood only with internal blower models MT-017 provided with the kit cod CBI-600A. For external and in-line blower prepa- ration please turn to page 12. 1.Remove the 6” round metal knockout plate from the blower plate by using a fl at head screwdriver. See.Fig.1 2. Remove the (6) screws securing the blower plate to the blower hou
Resumen del contenido incluido en la página 11
6. Attach the 6 pin male molex connector from blower wire to the 6 pin female molex connector located inside the blower housing. See Fig.6 7. Install blower and blower plate into blower housing by following the reverse instructions from step 2. See Fig.7 8. Connect 9 pin male molex connector from blower wire to 9 pin female molex connector on the capacitor wire. See Fig.8 WARNING! Place electrical wiring inside the motor housing. The hood is now ready to be installed on the wall. - 11 - I
Resumen del contenido incluido en la página 12
www.zephyronline.com The following instructions are for preparing the hood for use with an ex- ternal or in-line blowers models CBE-1000 or PBN-1000A. CAUTION: To reduce the risk of fi re and electric shock, install this rangehood only with remote blowers rated maximum 6.2 A. For internal blower instructions please turn to page 10. 1. Remove the (6) screws securing the blower pla- te to the blower housing and remove blower plate. See.Fig.1 2. Detach rectangular metal plate from blower pla
Resumen del contenido incluido en la página 13
6. Insert the 6 pin female molex connector into the junction box. See Fig. 6A. Secure remote blower junction box to top of blower housing using (2) screws. See Fig. 6B 7. Feed remote blower wire harness through remote blower junction box cover and Connect the wires with those inside the junction box. See Fig. 7 Note: Carry out the power supplly connection in accordance with the national electric code, ANSI/NFPA 70-1999. 8.Secure cover to junction box using (2) screws. Note1: A cable loc
Resumen del contenido incluido en la página 14
www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating op- tion. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certif ed Silver Tape or Duct Tape. Some Ducting Options - 14 - Installation - Ducting Options
Resumen del contenido incluido en la página 15
MOUNTING HEIGHTS The range hood must be installed at a minimum eight of 24 inches (71cm) from the cooking surface. If a connecting duct work composed of two parts is used, the upper part must be placed outside the lower part. Do not connect he range hood duct to the same duct used to exhaust hot air or fumes from another appliance. Before proceeding with the assembly instructions
remove the decorative mesh fi lters so that the range hood is esier to handle. MOUN
Resumen del contenido incluido en la página 16
www.zephyronline.com GENERAL • Carefully read the following important information regarding installation safety and maintenance. Keep this information booklet accessible for further consultations. POWER SUPPLY CONNECTION For connection to the power supply refer to the following: 1. Lift the bottom part of the duct cover and secure it carefully using adhesive tape. 2. Remove the power supply cover by un- doing the (2) screws Fig. 17. 3. Break through the hole on the box co- ver. 4. Secure t
Resumen del contenido incluido en la página 17
MOUNTING THE DUCT COVER 1. Install the electrical wiring and test hood for functions prior to installing the duct covers. 2. If using hood in air recirculating mode make sure to install the air diverter plate prior to mounting the duct covers. See the manual included with the recirculating kit for more instructions. 3. Adjust the width of the duct cover support bra- cket so that it fi ts inside the top of the chimney and observing the distance shown in Fig.10 4. Secure duct cover bra
Resumen del contenido incluido en la página 18
www.zephyronline.com MAINTENANCE • It is recommended to operate the appliance prior to cooking. It is recommended to leave the appliance in operation for 5 minutes after cooking is completed in order to completely eliminate cooking vapors and odors. The proper function of the range hood is conditioned by the regularity of maintenance. • The decorative mesh fi lters capture the grease particles suspended in the air and are therefore subject to clogging because of frequent use. In order to p
Resumen del contenido incluido en la página 19
DESCRIPTION HOOD PART# REPLACEMENT PARTS Light Bulb GU4, 20W (each) APN Z0B0030 OPTIONAL ACCESSORIES Recirculating Kit APN ZRC-00PN Replacement Charcoal Filters APN Z0F-00AC Duct Cover Extension APN Z1C-00PN To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368 - 19 - List of Parts and Accessories
Resumen del contenido incluido en la página 20
www.zephyronline.com - 20 -